Cargando…

Effects of different CT value assignment methods on dose calculations in radiotherapy planning for brain metastases

BACKGROUND: To study the effects of different CT value assignment methods on the dose calculations in radiotherapy plans for brain metastases, this study will provide a reference for radiotherapy planning design based on MR images. METHODS: All fifty recruited patients underwent CT and MR simulated...

Descripción completa

Detalles Bibliográficos
Autores principales: Ren, Jianxin, Gong, Guanzhong, Ma, Xingmin, Yao, Xinsen, Yin, Yong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8798516/
https://www.ncbi.nlm.nih.gov/pubmed/35117453
http://dx.doi.org/10.21037/tcr.2019.12.54
_version_ 1784641826538389504
author Ren, Jianxin
Gong, Guanzhong
Ma, Xingmin
Yao, Xinsen
Yin, Yong
author_facet Ren, Jianxin
Gong, Guanzhong
Ma, Xingmin
Yao, Xinsen
Yin, Yong
author_sort Ren, Jianxin
collection PubMed
description BACKGROUND: To study the effects of different CT value assignment methods on the dose calculations in radiotherapy plans for brain metastases, this study will provide a reference for radiotherapy planning design based on MR images. METHODS: All fifty recruited patients underwent CT and MR simulated localization the same day as, but prior to, three dimensional conformal radiation therapy (3D-CRT) or intensity modulated radiation therapy (IMRT) for brain metastases. After rigid registration of both the CT and MR images, the main tissues and organs were delineated on the CT and MR images. The average CT value of each tissue or organ was calculated. Three groups of pseudo-CT were generated by three CT value assignment methods: (I) the whole tissue was assigned 140 HU; (II) cavity, bone and other tissues were assigned −700, 700 and 20 HU, respectively; (III) tissue- and organ-specific CT values were given. The dose distribution was recalculated based on the three groups of pseudo-CT to obtain Plan2, Plan3 and Plan4, accordingly. The resultant radiotherapy plans were considered the original plan (Plan1). Then, the dosimetric differences between these three plans and Plan1 were compared. RESULTS: The average pseudo-CT values of bone and cavity were 731.7±69.3 and −725.5±26.1 HU, respectively. The range of average soft-tissue CT values was from −70 to 70 HU. The dose distribution between Plan1 and Plan2, Plan3 or Plan4 showed some differences, and the differences decreased in turn. The differences in the maximum dose of the lenses can reach 5.0%, 1.5% and 1.2%, respectively, while the differences in other dose parameters (maximum dose, mean dose and D(98%) to the PTV, D(5%) of the brainstem, and maximum dose of the brainstem, corpus callosum, left eye, right eye) were basically less than 2.0%, 1.2% and 0.8%, respectively. This shows that in the CT value assignment method, the dose calculation error can be greatly reduced by assigning the value to the bone and cavity separately, and if the different soft tissues are distinguished, the error of the dose calculation can be further reduced by more than 30%. In the pixel-by-pixel dosimetric comparison, the areas of more than 1% dose difference between Plan1 and Plan3 as well as Plan4 were mainly distributed near skin while those between Plan1 and Plan2 were mainly distributed at the bone, cavity, bone and soft tissues junction, and the skin near the field. CONCLUSIONS: In summary, a scheme for assigning specific CT values to MRI-based radiotherapy is established. The scheme will provide patients with a dose-free radiotherapy plan. Through the calculation of the differences between the new plans and the old plan, it is found that our scheme can basically control the dose error below 0.8% to meet the clinical requirements.
format Online
Article
Text
id pubmed-8798516
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-87985162022-02-02 Effects of different CT value assignment methods on dose calculations in radiotherapy planning for brain metastases Ren, Jianxin Gong, Guanzhong Ma, Xingmin Yao, Xinsen Yin, Yong Transl Cancer Res Original Article BACKGROUND: To study the effects of different CT value assignment methods on the dose calculations in radiotherapy plans for brain metastases, this study will provide a reference for radiotherapy planning design based on MR images. METHODS: All fifty recruited patients underwent CT and MR simulated localization the same day as, but prior to, three dimensional conformal radiation therapy (3D-CRT) or intensity modulated radiation therapy (IMRT) for brain metastases. After rigid registration of both the CT and MR images, the main tissues and organs were delineated on the CT and MR images. The average CT value of each tissue or organ was calculated. Three groups of pseudo-CT were generated by three CT value assignment methods: (I) the whole tissue was assigned 140 HU; (II) cavity, bone and other tissues were assigned −700, 700 and 20 HU, respectively; (III) tissue- and organ-specific CT values were given. The dose distribution was recalculated based on the three groups of pseudo-CT to obtain Plan2, Plan3 and Plan4, accordingly. The resultant radiotherapy plans were considered the original plan (Plan1). Then, the dosimetric differences between these three plans and Plan1 were compared. RESULTS: The average pseudo-CT values of bone and cavity were 731.7±69.3 and −725.5±26.1 HU, respectively. The range of average soft-tissue CT values was from −70 to 70 HU. The dose distribution between Plan1 and Plan2, Plan3 or Plan4 showed some differences, and the differences decreased in turn. The differences in the maximum dose of the lenses can reach 5.0%, 1.5% and 1.2%, respectively, while the differences in other dose parameters (maximum dose, mean dose and D(98%) to the PTV, D(5%) of the brainstem, and maximum dose of the brainstem, corpus callosum, left eye, right eye) were basically less than 2.0%, 1.2% and 0.8%, respectively. This shows that in the CT value assignment method, the dose calculation error can be greatly reduced by assigning the value to the bone and cavity separately, and if the different soft tissues are distinguished, the error of the dose calculation can be further reduced by more than 30%. In the pixel-by-pixel dosimetric comparison, the areas of more than 1% dose difference between Plan1 and Plan3 as well as Plan4 were mainly distributed near skin while those between Plan1 and Plan2 were mainly distributed at the bone, cavity, bone and soft tissues junction, and the skin near the field. CONCLUSIONS: In summary, a scheme for assigning specific CT values to MRI-based radiotherapy is established. The scheme will provide patients with a dose-free radiotherapy plan. Through the calculation of the differences between the new plans and the old plan, it is found that our scheme can basically control the dose error below 0.8% to meet the clinical requirements. AME Publishing Company 2020-02 /pmc/articles/PMC8798516/ /pubmed/35117453 http://dx.doi.org/10.21037/tcr.2019.12.54 Text en 2020 Translational Cancer Research. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0/.
spellingShingle Original Article
Ren, Jianxin
Gong, Guanzhong
Ma, Xingmin
Yao, Xinsen
Yin, Yong
Effects of different CT value assignment methods on dose calculations in radiotherapy planning for brain metastases
title Effects of different CT value assignment methods on dose calculations in radiotherapy planning for brain metastases
title_full Effects of different CT value assignment methods on dose calculations in radiotherapy planning for brain metastases
title_fullStr Effects of different CT value assignment methods on dose calculations in radiotherapy planning for brain metastases
title_full_unstemmed Effects of different CT value assignment methods on dose calculations in radiotherapy planning for brain metastases
title_short Effects of different CT value assignment methods on dose calculations in radiotherapy planning for brain metastases
title_sort effects of different ct value assignment methods on dose calculations in radiotherapy planning for brain metastases
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8798516/
https://www.ncbi.nlm.nih.gov/pubmed/35117453
http://dx.doi.org/10.21037/tcr.2019.12.54
work_keys_str_mv AT renjianxin effectsofdifferentctvalueassignmentmethodsondosecalculationsinradiotherapyplanningforbrainmetastases
AT gongguanzhong effectsofdifferentctvalueassignmentmethodsondosecalculationsinradiotherapyplanningforbrainmetastases
AT maxingmin effectsofdifferentctvalueassignmentmethodsondosecalculationsinradiotherapyplanningforbrainmetastases
AT yaoxinsen effectsofdifferentctvalueassignmentmethodsondosecalculationsinradiotherapyplanningforbrainmetastases
AT yinyong effectsofdifferentctvalueassignmentmethodsondosecalculationsinradiotherapyplanningforbrainmetastases