Cargando…
Report on outcomes of valve-in-valve transcatheter aortic valve implantation and redo surgical aortic valve replacement in the Netherlands
OBJECTIVE: We sought to investigate real-world outcomes of patients with degenerated biological aortic valve prostheses who had undergone valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) or reoperative surgical aortic valve replacement (redo-SAVR) in the Netherlands. METHODS: Patien...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Bohn Stafleu van Loghum
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8799804/ https://www.ncbi.nlm.nih.gov/pubmed/34373997 http://dx.doi.org/10.1007/s12471-021-01608-0 |
Sumario: | OBJECTIVE: We sought to investigate real-world outcomes of patients with degenerated biological aortic valve prostheses who had undergone valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) or reoperative surgical aortic valve replacement (redo-SAVR) in the Netherlands. METHODS: Patients who had undergone ViV-TAVI or redo-SAVR for a degenerated biological aortic valve prosthesis in the Netherlands between January 2014 and December 2018 were eligible for this retrospective study. Patients with a prior homograft, active endocarditis or mechanical aortic valve prosthesis were excluded. Patients were matched using the propensity score. The primary endpoint was a composite of 30-day all-cause mortality and in-hospital postoperative stroke. Secondary endpoints were all-cause mortality at different time points, in-hospital postoperative stroke, pacemaker implantation and redo procedures within one year. Baseline characteristics and outcome data were collected from the Netherlands Heart Registration. RESULTS: From 16 cardiac centres, 653 patients were included in the study (374 ViV-TAVI and 279 redo-SAVR). European System for Cardiac Operative Risk Evaluation I (EuroSCORE I) was higher in ViV-TAVI patients (19.4, interquartile range (IQR) 13.3–27.9 vs 13.8, IQR 8.3–21.9, p < 0.01). After propensity score matching, 165 patients were matched with acceptable covariate balance. In the matched cohorts, the primary endpoint was not significantly different for ViV-TAVI and redo-SAVR patients (odds ratio 1.30, 95% confidence interval 0.57–3.02). Procedural, 30-day and 1‑year all-cause mortality rates, incidence of in-hospital postoperative stroke, pacemaker implantation and redo procedures within one year were also similar between cohorts. CONCLUSION: Patients with degenerated aortic bioprostheses treated with ViV-TAVI or redo-SAVR have similar mortality and morbidity. SUPPLEMENTARY INFORMATION: The online version of this article (10.1007/s12471-021-01608-0) contains supplementary material, which is available to authorized users. |
---|