Cargando…
Finite element analysis of the Union Plate in treating elderly acetabular fracture patients
BACKGROUND: Elderly acetabular fractures are one of the more difficult types of fractures to resolve. For patients at this age, the more common type of fracture is comminuted. How to better fix this type of fracture has always been an issue of concern. This study was performed to observe the mechani...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8800209/ https://www.ncbi.nlm.nih.gov/pubmed/35093112 http://dx.doi.org/10.1186/s13018-022-02951-7 |
_version_ | 1784642210316156928 |
---|---|
author | Huang, Guixiong Chen, Kaifang Wang, Yulong Guo, Xiaodong |
author_facet | Huang, Guixiong Chen, Kaifang Wang, Yulong Guo, Xiaodong |
author_sort | Huang, Guixiong |
collection | PubMed |
description | BACKGROUND: Elderly acetabular fractures are one of the more difficult types of fractures to resolve. For patients at this age, the more common type of fracture is comminuted. How to better fix this type of fracture has always been an issue of concern. This study was performed to observe the mechanical properties of different internal fixation methods used in treating elderly acetabular fracture patients. METHODS: A model of a comminuted acetabular fracture in osteoporosis was established, consisting of an anterior column–posterior hemitransverse fracture with disruption of the quadrilateral surface. Fixation of the acetabular fracture model using a reconstruction plate and Union Plates was simulated. For the different internal fixation methods, static and transient modal analyses were performed under different loads, with an action time of 0.21 s and an analysis time of 0.7 s. The stress of the model was observed in the static analysis, and the displacement of the nodes and the entire model in the U1 direction was observed in the transient modal analysis. RESULTS: In the static analysis, the stress of the osteoporosis model, the suprapectineal pelvic reconstruction plate model, the infrapectineal quadrilateral surface buttress plate model, and the suprapectineal quadrilateral surface buttress plate model were 42.62 MPa, 37.49 MPa, 44.39 MPa, and 46.15 MPa, respectively. The stress was mainly distributed near the suprapubic branch. The corresponding displacement in the U1 direction was 0.1500 mm, 0.1020 mm, 0.0836 mm, and 0.0990 mm, respectively. In the transient modal analysis, there was a significant difference in displacement between the different models (P < 0.05). When different loads were applied with the same fixation method, there was no significant difference in model displacement (P > 0.05). CONCLUSION: Static and transient modal analyses show that the infrapectineal quadrilateral surface buttress plate or the suprapectineal quadrilateral surface buttress plate has an advantage in maintaining the stability of fracture fragments when fixing comminuted acetabular fractures in elderly individuals. The infrapectineal quadrilateral surface buttress plate also presents better biomechanical results. |
format | Online Article Text |
id | pubmed-8800209 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-88002092022-02-02 Finite element analysis of the Union Plate in treating elderly acetabular fracture patients Huang, Guixiong Chen, Kaifang Wang, Yulong Guo, Xiaodong J Orthop Surg Res Research Article BACKGROUND: Elderly acetabular fractures are one of the more difficult types of fractures to resolve. For patients at this age, the more common type of fracture is comminuted. How to better fix this type of fracture has always been an issue of concern. This study was performed to observe the mechanical properties of different internal fixation methods used in treating elderly acetabular fracture patients. METHODS: A model of a comminuted acetabular fracture in osteoporosis was established, consisting of an anterior column–posterior hemitransverse fracture with disruption of the quadrilateral surface. Fixation of the acetabular fracture model using a reconstruction plate and Union Plates was simulated. For the different internal fixation methods, static and transient modal analyses were performed under different loads, with an action time of 0.21 s and an analysis time of 0.7 s. The stress of the model was observed in the static analysis, and the displacement of the nodes and the entire model in the U1 direction was observed in the transient modal analysis. RESULTS: In the static analysis, the stress of the osteoporosis model, the suprapectineal pelvic reconstruction plate model, the infrapectineal quadrilateral surface buttress plate model, and the suprapectineal quadrilateral surface buttress plate model were 42.62 MPa, 37.49 MPa, 44.39 MPa, and 46.15 MPa, respectively. The stress was mainly distributed near the suprapubic branch. The corresponding displacement in the U1 direction was 0.1500 mm, 0.1020 mm, 0.0836 mm, and 0.0990 mm, respectively. In the transient modal analysis, there was a significant difference in displacement between the different models (P < 0.05). When different loads were applied with the same fixation method, there was no significant difference in model displacement (P > 0.05). CONCLUSION: Static and transient modal analyses show that the infrapectineal quadrilateral surface buttress plate or the suprapectineal quadrilateral surface buttress plate has an advantage in maintaining the stability of fracture fragments when fixing comminuted acetabular fractures in elderly individuals. The infrapectineal quadrilateral surface buttress plate also presents better biomechanical results. BioMed Central 2022-01-29 /pmc/articles/PMC8800209/ /pubmed/35093112 http://dx.doi.org/10.1186/s13018-022-02951-7 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Huang, Guixiong Chen, Kaifang Wang, Yulong Guo, Xiaodong Finite element analysis of the Union Plate in treating elderly acetabular fracture patients |
title | Finite element analysis of the Union Plate in treating elderly acetabular fracture patients |
title_full | Finite element analysis of the Union Plate in treating elderly acetabular fracture patients |
title_fullStr | Finite element analysis of the Union Plate in treating elderly acetabular fracture patients |
title_full_unstemmed | Finite element analysis of the Union Plate in treating elderly acetabular fracture patients |
title_short | Finite element analysis of the Union Plate in treating elderly acetabular fracture patients |
title_sort | finite element analysis of the union plate in treating elderly acetabular fracture patients |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8800209/ https://www.ncbi.nlm.nih.gov/pubmed/35093112 http://dx.doi.org/10.1186/s13018-022-02951-7 |
work_keys_str_mv | AT huangguixiong finiteelementanalysisoftheunionplateintreatingelderlyacetabularfracturepatients AT chenkaifang finiteelementanalysisoftheunionplateintreatingelderlyacetabularfracturepatients AT wangyulong finiteelementanalysisoftheunionplateintreatingelderlyacetabularfracturepatients AT guoxiaodong finiteelementanalysisoftheunionplateintreatingelderlyacetabularfracturepatients |