Cargando…

Safety and feasibility of transradial aortic valve valvuloplasty (TRAV study)

INTRODUCTION: The importance of balloon aortic valvuloplasty (BAV) in the transcatheter aortic valve implantation (TAVI) era emerged in the past decades, but the access site related complication rate remained significant. AIM: To establish the safety and technical success of transradial balloon aort...

Descripción completa

Detalles Bibliográficos
Autores principales: Molnár, Levente, Papp, Roland, Szigethi, Tímea, Édes, István F., Becker, Dávid, Bertrand, Olivier F., Merkely, Béla, Ruzsa, Zoltán
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8802645/
https://www.ncbi.nlm.nih.gov/pubmed/35126553
http://dx.doi.org/10.5114/aic.2021.111341
Descripción
Sumario:INTRODUCTION: The importance of balloon aortic valvuloplasty (BAV) in the transcatheter aortic valve implantation (TAVI) era emerged in the past decades, but the access site related complication rate remained significant. AIM: To establish the safety and technical success of transradial balloon aortic valvuloplasty (trBAV). The secondary objective was to determine the effectiveness and appropriate role of trBAV. MATERIAL AND METHODS: Between 2017 and 2019, 36 consecutive patients with symptomatic aortic stenosis (AoS) were treated with trBAV in this prospective, single-center study. During the procedure, the efficacy and the aortic valve insufficiency were controlled by hemodynamic measurements and later by echocardiography. The primary end-points were technical success and major adverse events (MAE). Secondary end-points were the access site complication rate, hemodynamic and clinical result of the intervention, procedure-related factors, crossover rate to the femoral access site and hospitalization duration. RESULTS: Clinical and technical success was achieved in all cases. Invasively measured peak-to-peak gradient decreased from 76.8 ±27.2 to 54.7 ±21.1 mm Hg (p = 0.001), and the aortic-valve area increased from 0.69 ±0.2 to 0.91 ±0.3 cm(2) (p = 0.001). No major adverse cardiac or cerebrovascular events or vascular complications (according to VARC 2 criteria) occurred during the procedures. The perioperative death rate was 2.7% (n = 1). CONCLUSIONS: According to our study, radial artery access is a safe and effective option for balloon aortic valvuloplasty in patients with severe aortic valve stenosis.