Cargando…

Intra-tracheal multiplexed sensing of contact pressure and perfusion

Incorrect endotracheal tube (ETT) cuff inflation pressure causes significant problems for intubated patients. The technical development and first in vivo use of a smart ETT for measurements at the cuff-trachea interface during mechanical ventilation are described. The intra-tracheal multiplexed sens...

Descripción completa

Detalles Bibliográficos
Autores principales: Correia, Ricardo, Gadsby, Brett, Korposh, Sergiy, Norris, Andrew M., Hayes-Gill, Barrie R., Sinha, Rishie, Hardman, Jonathan G., Gardner, David S., Talbot, Simon, Harvey, Daniel, McGlashan, Julian, Morgan, Stephen P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Optical Society of America 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8803015/
https://www.ncbi.nlm.nih.gov/pubmed/35154853
http://dx.doi.org/10.1364/BOE.442165
_version_ 1784642785107771392
author Correia, Ricardo
Gadsby, Brett
Korposh, Sergiy
Norris, Andrew M.
Hayes-Gill, Barrie R.
Sinha, Rishie
Hardman, Jonathan G.
Gardner, David S.
Talbot, Simon
Harvey, Daniel
McGlashan, Julian
Morgan, Stephen P.
author_facet Correia, Ricardo
Gadsby, Brett
Korposh, Sergiy
Norris, Andrew M.
Hayes-Gill, Barrie R.
Sinha, Rishie
Hardman, Jonathan G.
Gardner, David S.
Talbot, Simon
Harvey, Daniel
McGlashan, Julian
Morgan, Stephen P.
author_sort Correia, Ricardo
collection PubMed
description Incorrect endotracheal tube (ETT) cuff inflation pressure causes significant problems for intubated patients. The technical development and first in vivo use of a smart ETT for measurements at the cuff-trachea interface during mechanical ventilation are described. The intra-tracheal multiplexed sensing (iTraXS) ETT contains integrated optical fibre sensors to measure contact pressure and blood perfusion. The device is tested during mechanical ventilation in a porcine model (N=6). For contact pressure, signals were obtained in all 30 measurements. For perfusion, data could be obtained in all 33 measurements. In the 3 cases where the cuff was inflated to an artificially high-level, blood occlusion is observed.
format Online
Article
Text
id pubmed-8803015
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Optical Society of America
record_format MEDLINE/PubMed
spelling pubmed-88030152022-02-10 Intra-tracheal multiplexed sensing of contact pressure and perfusion Correia, Ricardo Gadsby, Brett Korposh, Sergiy Norris, Andrew M. Hayes-Gill, Barrie R. Sinha, Rishie Hardman, Jonathan G. Gardner, David S. Talbot, Simon Harvey, Daniel McGlashan, Julian Morgan, Stephen P. Biomed Opt Express Article Incorrect endotracheal tube (ETT) cuff inflation pressure causes significant problems for intubated patients. The technical development and first in vivo use of a smart ETT for measurements at the cuff-trachea interface during mechanical ventilation are described. The intra-tracheal multiplexed sensing (iTraXS) ETT contains integrated optical fibre sensors to measure contact pressure and blood perfusion. The device is tested during mechanical ventilation in a porcine model (N=6). For contact pressure, signals were obtained in all 30 measurements. For perfusion, data could be obtained in all 33 measurements. In the 3 cases where the cuff was inflated to an artificially high-level, blood occlusion is observed. Optical Society of America 2021-12-03 /pmc/articles/PMC8803015/ /pubmed/35154853 http://dx.doi.org/10.1364/BOE.442165 Text en Published by The Optical Society under the terms of the Creative Commons Attribution 4.0 License. Further distribution of this work must maintain attribution to the author(s) and the published article’s title, journal citation, and DOI. https://creativecommons.org/licenses/by/4.0/ https://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Correia, Ricardo
Gadsby, Brett
Korposh, Sergiy
Norris, Andrew M.
Hayes-Gill, Barrie R.
Sinha, Rishie
Hardman, Jonathan G.
Gardner, David S.
Talbot, Simon
Harvey, Daniel
McGlashan, Julian
Morgan, Stephen P.
Intra-tracheal multiplexed sensing of contact pressure and perfusion
title Intra-tracheal multiplexed sensing of contact pressure and perfusion
title_full Intra-tracheal multiplexed sensing of contact pressure and perfusion
title_fullStr Intra-tracheal multiplexed sensing of contact pressure and perfusion
title_full_unstemmed Intra-tracheal multiplexed sensing of contact pressure and perfusion
title_short Intra-tracheal multiplexed sensing of contact pressure and perfusion
title_sort intra-tracheal multiplexed sensing of contact pressure and perfusion
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8803015/
https://www.ncbi.nlm.nih.gov/pubmed/35154853
http://dx.doi.org/10.1364/BOE.442165
work_keys_str_mv AT correiaricardo intratrachealmultiplexedsensingofcontactpressureandperfusion
AT gadsbybrett intratrachealmultiplexedsensingofcontactpressureandperfusion
AT korposhsergiy intratrachealmultiplexedsensingofcontactpressureandperfusion
AT norrisandrewm intratrachealmultiplexedsensingofcontactpressureandperfusion
AT hayesgillbarrier intratrachealmultiplexedsensingofcontactpressureandperfusion
AT sinharishie intratrachealmultiplexedsensingofcontactpressureandperfusion
AT hardmanjonathang intratrachealmultiplexedsensingofcontactpressureandperfusion
AT gardnerdavids intratrachealmultiplexedsensingofcontactpressureandperfusion
AT talbotsimon intratrachealmultiplexedsensingofcontactpressureandperfusion
AT harveydaniel intratrachealmultiplexedsensingofcontactpressureandperfusion
AT mcglashanjulian intratrachealmultiplexedsensingofcontactpressureandperfusion
AT morganstephenp intratrachealmultiplexedsensingofcontactpressureandperfusion