Image Quality and Pulmonary Nodule Detectability at Low-dose Computed Tomography (low kVp and mAs): A phantom study

BACKGROUND: Nowadays, there has been a growing demand for low-dose computed tomography (LDCT) protocols. CT has a critical role in the management of the diagnosis chain of pulmonary disease, especially in lung cancer screening. There have been introduced several dose reduction methods, however, most...

Descripción completa

Detalles Bibliográficos
Autores principales: Iranmakani, Sepideh, Jahanshahi, Amir Reza, Mehnati, Parinaz, Mortezazadeh, Tohid, Khezerloo, Davood
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8804592/
https://www.ncbi.nlm.nih.gov/pubmed/35265467
http://dx.doi.org/10.4103/jmss.JMSS_65_20
_version_ 1784643109111463936
author Iranmakani, Sepideh
Jahanshahi, Amir Reza
Mehnati, Parinaz
Mortezazadeh, Tohid
Khezerloo, Davood
author_facet Iranmakani, Sepideh
Jahanshahi, Amir Reza
Mehnati, Parinaz
Mortezazadeh, Tohid
Khezerloo, Davood
author_sort Iranmakani, Sepideh
collection PubMed
description BACKGROUND: Nowadays, there has been a growing demand for low-dose computed tomography (LDCT) protocols. CT has a critical role in the management of the diagnosis chain of pulmonary disease, especially in lung cancer screening. There have been introduced several dose reduction methods, however, most of them are time-consuming, intricate, and vendor-based strategies that are hardly used in clinics routinely. This study aims to evaluate the image quality and pulmonary nodule detectability of LDCT protocols that are feasible and easy implemented. Image quality was analyzed in a general quality control phantom (Gammex) and then in a manmade lung phantom with nodules-equivalent objects. METHODS: This study was designed in a two steps, in the first step, a feasible low-dose lung CT protocol was selected with quality assessment of accreditation phantom image. In the second step, the selected low-dose protocol with an appropriate image quality was performed on a manmade lung phantom in which there were objects equivalent to the pulmonary nodule. Finally, image quality parameters of the phantom at the appropriate scan protocol were compared with the standard protocol. RESULTS: A reduction of about 17% of kVp and 46% in tube current leads to dose reduction by about 70%. The contrast-to-noise ratio in the low-dose protocol remained almost unchanged. The signal-to-noise ratio in the low-dose protocol decreased by approximately 32%, and the noise level has increased by about 1.5 times. However, this reduction method hardly affected the detectability of nodules in man-made pulmonary phantom. CONCLUSIONS: Here, we demonstrated that the LDCT scan has an insignificant effect on the perception of lung nodules. In this study, patient dose in lung CT was reduced by modifying of kVp and mAs about approximately 70%. Hence, to step in toward low-dose strategies in medical imaging clinics, using easy-implemented and feasible low-dose strategies may be helpful.
format Online
Article
Text
id pubmed-8804592
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-88045922022-03-08 Image Quality and Pulmonary Nodule Detectability at Low-dose Computed Tomography (low kVp and mAs): A phantom study Iranmakani, Sepideh Jahanshahi, Amir Reza Mehnati, Parinaz Mortezazadeh, Tohid Khezerloo, Davood J Med Signals Sens Original Article BACKGROUND: Nowadays, there has been a growing demand for low-dose computed tomography (LDCT) protocols. CT has a critical role in the management of the diagnosis chain of pulmonary disease, especially in lung cancer screening. There have been introduced several dose reduction methods, however, most of them are time-consuming, intricate, and vendor-based strategies that are hardly used in clinics routinely. This study aims to evaluate the image quality and pulmonary nodule detectability of LDCT protocols that are feasible and easy implemented. Image quality was analyzed in a general quality control phantom (Gammex) and then in a manmade lung phantom with nodules-equivalent objects. METHODS: This study was designed in a two steps, in the first step, a feasible low-dose lung CT protocol was selected with quality assessment of accreditation phantom image. In the second step, the selected low-dose protocol with an appropriate image quality was performed on a manmade lung phantom in which there were objects equivalent to the pulmonary nodule. Finally, image quality parameters of the phantom at the appropriate scan protocol were compared with the standard protocol. RESULTS: A reduction of about 17% of kVp and 46% in tube current leads to dose reduction by about 70%. The contrast-to-noise ratio in the low-dose protocol remained almost unchanged. The signal-to-noise ratio in the low-dose protocol decreased by approximately 32%, and the noise level has increased by about 1.5 times. However, this reduction method hardly affected the detectability of nodules in man-made pulmonary phantom. CONCLUSIONS: Here, we demonstrated that the LDCT scan has an insignificant effect on the perception of lung nodules. In this study, patient dose in lung CT was reduced by modifying of kVp and mAs about approximately 70%. Hence, to step in toward low-dose strategies in medical imaging clinics, using easy-implemented and feasible low-dose strategies may be helpful. Wolters Kluwer - Medknow 2021-12-28 /pmc/articles/PMC8804592/ /pubmed/35265467 http://dx.doi.org/10.4103/jmss.JMSS_65_20 Text en Copyright: © 2021 Journal of Medical Signals & Sensors https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Iranmakani, Sepideh
Jahanshahi, Amir Reza
Mehnati, Parinaz
Mortezazadeh, Tohid
Khezerloo, Davood
Image Quality and Pulmonary Nodule Detectability at Low-dose Computed Tomography (low kVp and mAs): A phantom study
title Image Quality and Pulmonary Nodule Detectability at Low-dose Computed Tomography (low kVp and mAs): A phantom study
title_full Image Quality and Pulmonary Nodule Detectability at Low-dose Computed Tomography (low kVp and mAs): A phantom study
title_fullStr Image Quality and Pulmonary Nodule Detectability at Low-dose Computed Tomography (low kVp and mAs): A phantom study
title_full_unstemmed Image Quality and Pulmonary Nodule Detectability at Low-dose Computed Tomography (low kVp and mAs): A phantom study
title_short Image Quality and Pulmonary Nodule Detectability at Low-dose Computed Tomography (low kVp and mAs): A phantom study
title_sort image quality and pulmonary nodule detectability at low-dose computed tomography (low kvp and mas): a phantom study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8804592/
https://www.ncbi.nlm.nih.gov/pubmed/35265467
http://dx.doi.org/10.4103/jmss.JMSS_65_20
work_keys_str_mv AT iranmakanisepideh imagequalityandpulmonarynoduledetectabilityatlowdosecomputedtomographylowkvpandmasaphantomstudy
AT jahanshahiamirreza imagequalityandpulmonarynoduledetectabilityatlowdosecomputedtomographylowkvpandmasaphantomstudy
AT mehnatiparinaz imagequalityandpulmonarynoduledetectabilityatlowdosecomputedtomographylowkvpandmasaphantomstudy
AT mortezazadehtohid imagequalityandpulmonarynoduledetectabilityatlowdosecomputedtomographylowkvpandmasaphantomstudy
AT khezerloodavood imagequalityandpulmonarynoduledetectabilityatlowdosecomputedtomographylowkvpandmasaphantomstudy