Cargando…
Feasibility, reproducibility and characteristics of coronary bifurcation type assessment by three-dimensional optical coherence tomography
AIM: To investigate the characteristics of coronary artery bifurcation type (parallel or perpendicular type) using three-dimensional (3D) optical coherence tomography (OCT), and determine the feasibility, reproducibility, assessment time and correlation with bifurcation angles measured by 3D quantit...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8806074/ https://www.ncbi.nlm.nih.gov/pubmed/35104282 http://dx.doi.org/10.1371/journal.pone.0263246 |
_version_ | 1784643368664432640 |
---|---|
author | Nishimura, Takashi Okamura, Takayuki Fujimura, Tatsuhiro Miyazaki, Yosuke Takenaka, Hitoshi Akase, Hideaki Tateishi, Hiroki Mochizuki, Mamoru Uchinoumi, Hitoshi Oda, Tetsuro Yano, Masafumi |
author_facet | Nishimura, Takashi Okamura, Takayuki Fujimura, Tatsuhiro Miyazaki, Yosuke Takenaka, Hitoshi Akase, Hideaki Tateishi, Hiroki Mochizuki, Mamoru Uchinoumi, Hitoshi Oda, Tetsuro Yano, Masafumi |
author_sort | Nishimura, Takashi |
collection | PubMed |
description | AIM: To investigate the characteristics of coronary artery bifurcation type (parallel or perpendicular type) using three-dimensional (3D) optical coherence tomography (OCT), and determine the feasibility, reproducibility, assessment time and correlation with bifurcation angles measured by 3D quantitative coronary angiography (QCA). METHODS AND RESULTS: We evaluated 60 lesions at the coronary bifurcation that were treated by main vessel (MV) stenting with kissing balloon inflation (KBI) under OCT/optical frequency domain imaging (OFDI) guidance. Inter- and intra-observer agreement regarding the assessment of 3D bifurcation types were 0.88 and 0.94, respectively. The assessment times of 3D-OCT bifurcation type with OCT and OFDI were within about 30 seconds. 3D-OCT bifurcation types showed the greatest correlation with the distal bifurcation angle assessed by 3D-QCA among the three bifurcation angles (distal bifurcation angle, proximal bifurcation angle and main vessel angle), and the optimal cut-off distal bifurcation angle to predict a perpendicular type bifurcation, as determined by ROC analysis, was 51.0° (AUC 0.773, sensitivity 0.80, specificity 0.67). Based on this cut-off value for the distal bifurcation angle (51°), the diagnostic accuracy for perpendicular type bifurcation in cases with a BA ≥ 51° (n = 34) was 70.6% (24/34) and that of the parallel type bifurcation in cases of BA < 51° (n = 26) was 76.9% (20/26). CONCLUSION: Performing 3D-OCT for assessment of coronary artery bifurcation type is feasible and simple, and can be done in a short time with high reproducibility. |
format | Online Article Text |
id | pubmed-8806074 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-88060742022-02-02 Feasibility, reproducibility and characteristics of coronary bifurcation type assessment by three-dimensional optical coherence tomography Nishimura, Takashi Okamura, Takayuki Fujimura, Tatsuhiro Miyazaki, Yosuke Takenaka, Hitoshi Akase, Hideaki Tateishi, Hiroki Mochizuki, Mamoru Uchinoumi, Hitoshi Oda, Tetsuro Yano, Masafumi PLoS One Research Article AIM: To investigate the characteristics of coronary artery bifurcation type (parallel or perpendicular type) using three-dimensional (3D) optical coherence tomography (OCT), and determine the feasibility, reproducibility, assessment time and correlation with bifurcation angles measured by 3D quantitative coronary angiography (QCA). METHODS AND RESULTS: We evaluated 60 lesions at the coronary bifurcation that were treated by main vessel (MV) stenting with kissing balloon inflation (KBI) under OCT/optical frequency domain imaging (OFDI) guidance. Inter- and intra-observer agreement regarding the assessment of 3D bifurcation types were 0.88 and 0.94, respectively. The assessment times of 3D-OCT bifurcation type with OCT and OFDI were within about 30 seconds. 3D-OCT bifurcation types showed the greatest correlation with the distal bifurcation angle assessed by 3D-QCA among the three bifurcation angles (distal bifurcation angle, proximal bifurcation angle and main vessel angle), and the optimal cut-off distal bifurcation angle to predict a perpendicular type bifurcation, as determined by ROC analysis, was 51.0° (AUC 0.773, sensitivity 0.80, specificity 0.67). Based on this cut-off value for the distal bifurcation angle (51°), the diagnostic accuracy for perpendicular type bifurcation in cases with a BA ≥ 51° (n = 34) was 70.6% (24/34) and that of the parallel type bifurcation in cases of BA < 51° (n = 26) was 76.9% (20/26). CONCLUSION: Performing 3D-OCT for assessment of coronary artery bifurcation type is feasible and simple, and can be done in a short time with high reproducibility. Public Library of Science 2022-02-01 /pmc/articles/PMC8806074/ /pubmed/35104282 http://dx.doi.org/10.1371/journal.pone.0263246 Text en © 2022 Nishimura et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Nishimura, Takashi Okamura, Takayuki Fujimura, Tatsuhiro Miyazaki, Yosuke Takenaka, Hitoshi Akase, Hideaki Tateishi, Hiroki Mochizuki, Mamoru Uchinoumi, Hitoshi Oda, Tetsuro Yano, Masafumi Feasibility, reproducibility and characteristics of coronary bifurcation type assessment by three-dimensional optical coherence tomography |
title | Feasibility, reproducibility and characteristics of coronary bifurcation type assessment by three-dimensional optical coherence tomography |
title_full | Feasibility, reproducibility and characteristics of coronary bifurcation type assessment by three-dimensional optical coherence tomography |
title_fullStr | Feasibility, reproducibility and characteristics of coronary bifurcation type assessment by three-dimensional optical coherence tomography |
title_full_unstemmed | Feasibility, reproducibility and characteristics of coronary bifurcation type assessment by three-dimensional optical coherence tomography |
title_short | Feasibility, reproducibility and characteristics of coronary bifurcation type assessment by three-dimensional optical coherence tomography |
title_sort | feasibility, reproducibility and characteristics of coronary bifurcation type assessment by three-dimensional optical coherence tomography |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8806074/ https://www.ncbi.nlm.nih.gov/pubmed/35104282 http://dx.doi.org/10.1371/journal.pone.0263246 |
work_keys_str_mv | AT nishimuratakashi feasibilityreproducibilityandcharacteristicsofcoronarybifurcationtypeassessmentbythreedimensionalopticalcoherencetomography AT okamuratakayuki feasibilityreproducibilityandcharacteristicsofcoronarybifurcationtypeassessmentbythreedimensionalopticalcoherencetomography AT fujimuratatsuhiro feasibilityreproducibilityandcharacteristicsofcoronarybifurcationtypeassessmentbythreedimensionalopticalcoherencetomography AT miyazakiyosuke feasibilityreproducibilityandcharacteristicsofcoronarybifurcationtypeassessmentbythreedimensionalopticalcoherencetomography AT takenakahitoshi feasibilityreproducibilityandcharacteristicsofcoronarybifurcationtypeassessmentbythreedimensionalopticalcoherencetomography AT akasehideaki feasibilityreproducibilityandcharacteristicsofcoronarybifurcationtypeassessmentbythreedimensionalopticalcoherencetomography AT tateishihiroki feasibilityreproducibilityandcharacteristicsofcoronarybifurcationtypeassessmentbythreedimensionalopticalcoherencetomography AT mochizukimamoru feasibilityreproducibilityandcharacteristicsofcoronarybifurcationtypeassessmentbythreedimensionalopticalcoherencetomography AT uchinoumihitoshi feasibilityreproducibilityandcharacteristicsofcoronarybifurcationtypeassessmentbythreedimensionalopticalcoherencetomography AT odatetsuro feasibilityreproducibilityandcharacteristicsofcoronarybifurcationtypeassessmentbythreedimensionalopticalcoherencetomography AT yanomasafumi feasibilityreproducibilityandcharacteristicsofcoronarybifurcationtypeassessmentbythreedimensionalopticalcoherencetomography |