Cargando…

The ClearSight System for Postoperative Arterial Blood Pressure Monitoring After Carotid Endarterectomy: A Validation Study

BACKGROUND: The majority of postoperative events in patients undergoing carotid endarterectomy (CEA) are of hemodynamic origin, requiring preventive strict postoperative arterial blood pressure (BP) control. This study aimed to assess whether BP monitoring with noninvasive beat-to-beat ClearSight fi...

Descripción completa

Detalles Bibliográficos
Autores principales: Fassaert, Leonie M M, Plate, Joost D J, Westerink, Jan, Immink, Rogier V, de Borst, Gert J
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8807161/
https://www.ncbi.nlm.nih.gov/pubmed/34505631
http://dx.doi.org/10.1093/ajh/hpab140
_version_ 1784643623404437504
author Fassaert, Leonie M M
Plate, Joost D J
Westerink, Jan
Immink, Rogier V
de Borst, Gert J
author_facet Fassaert, Leonie M M
Plate, Joost D J
Westerink, Jan
Immink, Rogier V
de Borst, Gert J
author_sort Fassaert, Leonie M M
collection PubMed
description BACKGROUND: The majority of postoperative events in patients undergoing carotid endarterectomy (CEA) are of hemodynamic origin, requiring preventive strict postoperative arterial blood pressure (BP) control. This study aimed to assess whether BP monitoring with noninvasive beat-to-beat ClearSight finger BP (BP(CS)) can replace invasive beat-to-beat radial artery BP (BP(RAD)) in the postoperative phase. METHODS: This study was a single-center clinical validation study using a prespecified study protocol. In 48 patients with symptomatic carotid artery stenosis, BP(CS) and BP(RAD) were monitored ipsilateral in a simultaneous manner during a 6-hour period on the recovery unit following CEA. Primary endpoints were accuracy and precision of BP derived by ClearSight (Edward Lifesciences, Irvine, CA) vs. the reference standard (Arbocath 20 G, Hospira, Lake Forest, IL) to investigate if BP(CS) is a reliable noninvasive alternative for BP monitoring postoperatively in CEA patients. Validation was guided by the standard set by the Association for Advancement of Medical Instrumentation (AAMI), considering a BP-monitor adequate when bias (precision) is <5 (8) mm Hg. Secondary endpoint was percentage under- and overtreatment, defined as exceedance of individual postoperative systolic BP threshold by BP(RAD) or BP(CS) in contrast to BP(CS) or BP(RAD), respectively. RESULTS: The bias (precision) of BP(CS) compared to BP(RAD) was −10 (13.6), 8 (7.2) and 4 (7.8) mm Hg for systolic, diastolic and mean arterial pressure (MAP), respectively. Based on BP(CS), undertreatment was 5.6% and overtreatment was 2.4%; however, percentages of undertreatment quadrupled for lower systolic BP thresholds. CONCLUSIONS: Noninvasive MAP, but not systolic and diastolic BP, was similar to invasive BP(RAD) during postoperative observation following CEA, based on AAMI criteria. However, as systolic BP is currently leading in postoperative monitoring to adjust BP therapy on, BP(CS) is not a reliable alternative for BP(RAD.)
format Online
Article
Text
id pubmed-8807161
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-88071612022-02-02 The ClearSight System for Postoperative Arterial Blood Pressure Monitoring After Carotid Endarterectomy: A Validation Study Fassaert, Leonie M M Plate, Joost D J Westerink, Jan Immink, Rogier V de Borst, Gert J Am J Hypertens Original Articles BACKGROUND: The majority of postoperative events in patients undergoing carotid endarterectomy (CEA) are of hemodynamic origin, requiring preventive strict postoperative arterial blood pressure (BP) control. This study aimed to assess whether BP monitoring with noninvasive beat-to-beat ClearSight finger BP (BP(CS)) can replace invasive beat-to-beat radial artery BP (BP(RAD)) in the postoperative phase. METHODS: This study was a single-center clinical validation study using a prespecified study protocol. In 48 patients with symptomatic carotid artery stenosis, BP(CS) and BP(RAD) were monitored ipsilateral in a simultaneous manner during a 6-hour period on the recovery unit following CEA. Primary endpoints were accuracy and precision of BP derived by ClearSight (Edward Lifesciences, Irvine, CA) vs. the reference standard (Arbocath 20 G, Hospira, Lake Forest, IL) to investigate if BP(CS) is a reliable noninvasive alternative for BP monitoring postoperatively in CEA patients. Validation was guided by the standard set by the Association for Advancement of Medical Instrumentation (AAMI), considering a BP-monitor adequate when bias (precision) is <5 (8) mm Hg. Secondary endpoint was percentage under- and overtreatment, defined as exceedance of individual postoperative systolic BP threshold by BP(RAD) or BP(CS) in contrast to BP(CS) or BP(RAD), respectively. RESULTS: The bias (precision) of BP(CS) compared to BP(RAD) was −10 (13.6), 8 (7.2) and 4 (7.8) mm Hg for systolic, diastolic and mean arterial pressure (MAP), respectively. Based on BP(CS), undertreatment was 5.6% and overtreatment was 2.4%; however, percentages of undertreatment quadrupled for lower systolic BP thresholds. CONCLUSIONS: Noninvasive MAP, but not systolic and diastolic BP, was similar to invasive BP(RAD) during postoperative observation following CEA, based on AAMI criteria. However, as systolic BP is currently leading in postoperative monitoring to adjust BP therapy on, BP(CS) is not a reliable alternative for BP(RAD.) Oxford University Press 2021-09-10 /pmc/articles/PMC8807161/ /pubmed/34505631 http://dx.doi.org/10.1093/ajh/hpab140 Text en © The Author(s) 2021. Published by Oxford University Press on behalf of American Journal of Hypertension, Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Original Articles
Fassaert, Leonie M M
Plate, Joost D J
Westerink, Jan
Immink, Rogier V
de Borst, Gert J
The ClearSight System for Postoperative Arterial Blood Pressure Monitoring After Carotid Endarterectomy: A Validation Study
title The ClearSight System for Postoperative Arterial Blood Pressure Monitoring After Carotid Endarterectomy: A Validation Study
title_full The ClearSight System for Postoperative Arterial Blood Pressure Monitoring After Carotid Endarterectomy: A Validation Study
title_fullStr The ClearSight System for Postoperative Arterial Blood Pressure Monitoring After Carotid Endarterectomy: A Validation Study
title_full_unstemmed The ClearSight System for Postoperative Arterial Blood Pressure Monitoring After Carotid Endarterectomy: A Validation Study
title_short The ClearSight System for Postoperative Arterial Blood Pressure Monitoring After Carotid Endarterectomy: A Validation Study
title_sort clearsight system for postoperative arterial blood pressure monitoring after carotid endarterectomy: a validation study
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8807161/
https://www.ncbi.nlm.nih.gov/pubmed/34505631
http://dx.doi.org/10.1093/ajh/hpab140
work_keys_str_mv AT fassaertleoniemm theclearsightsystemforpostoperativearterialbloodpressuremonitoringaftercarotidendarterectomyavalidationstudy
AT platejoostdj theclearsightsystemforpostoperativearterialbloodpressuremonitoringaftercarotidendarterectomyavalidationstudy
AT westerinkjan theclearsightsystemforpostoperativearterialbloodpressuremonitoringaftercarotidendarterectomyavalidationstudy
AT imminkrogierv theclearsightsystemforpostoperativearterialbloodpressuremonitoringaftercarotidendarterectomyavalidationstudy
AT deborstgertj theclearsightsystemforpostoperativearterialbloodpressuremonitoringaftercarotidendarterectomyavalidationstudy
AT fassaertleoniemm clearsightsystemforpostoperativearterialbloodpressuremonitoringaftercarotidendarterectomyavalidationstudy
AT platejoostdj clearsightsystemforpostoperativearterialbloodpressuremonitoringaftercarotidendarterectomyavalidationstudy
AT westerinkjan clearsightsystemforpostoperativearterialbloodpressuremonitoringaftercarotidendarterectomyavalidationstudy
AT imminkrogierv clearsightsystemforpostoperativearterialbloodpressuremonitoringaftercarotidendarterectomyavalidationstudy
AT deborstgertj clearsightsystemforpostoperativearterialbloodpressuremonitoringaftercarotidendarterectomyavalidationstudy