The ClearSight System for Postoperative Arterial Blood Pressure Monitoring After Carotid Endarterectomy: A Validation Study
BACKGROUND: The majority of postoperative events in patients undergoing carotid endarterectomy (CEA) are of hemodynamic origin, requiring preventive strict postoperative arterial blood pressure (BP) control. This study aimed to assess whether BP monitoring with noninvasive beat-to-beat ClearSight fi...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8807161/ https://www.ncbi.nlm.nih.gov/pubmed/34505631 http://dx.doi.org/10.1093/ajh/hpab140 |
_version_ | 1784643623404437504 |
---|---|
author | Fassaert, Leonie M M Plate, Joost D J Westerink, Jan Immink, Rogier V de Borst, Gert J |
author_facet | Fassaert, Leonie M M Plate, Joost D J Westerink, Jan Immink, Rogier V de Borst, Gert J |
author_sort | Fassaert, Leonie M M |
collection | PubMed |
description | BACKGROUND: The majority of postoperative events in patients undergoing carotid endarterectomy (CEA) are of hemodynamic origin, requiring preventive strict postoperative arterial blood pressure (BP) control. This study aimed to assess whether BP monitoring with noninvasive beat-to-beat ClearSight finger BP (BP(CS)) can replace invasive beat-to-beat radial artery BP (BP(RAD)) in the postoperative phase. METHODS: This study was a single-center clinical validation study using a prespecified study protocol. In 48 patients with symptomatic carotid artery stenosis, BP(CS) and BP(RAD) were monitored ipsilateral in a simultaneous manner during a 6-hour period on the recovery unit following CEA. Primary endpoints were accuracy and precision of BP derived by ClearSight (Edward Lifesciences, Irvine, CA) vs. the reference standard (Arbocath 20 G, Hospira, Lake Forest, IL) to investigate if BP(CS) is a reliable noninvasive alternative for BP monitoring postoperatively in CEA patients. Validation was guided by the standard set by the Association for Advancement of Medical Instrumentation (AAMI), considering a BP-monitor adequate when bias (precision) is <5 (8) mm Hg. Secondary endpoint was percentage under- and overtreatment, defined as exceedance of individual postoperative systolic BP threshold by BP(RAD) or BP(CS) in contrast to BP(CS) or BP(RAD), respectively. RESULTS: The bias (precision) of BP(CS) compared to BP(RAD) was −10 (13.6), 8 (7.2) and 4 (7.8) mm Hg for systolic, diastolic and mean arterial pressure (MAP), respectively. Based on BP(CS), undertreatment was 5.6% and overtreatment was 2.4%; however, percentages of undertreatment quadrupled for lower systolic BP thresholds. CONCLUSIONS: Noninvasive MAP, but not systolic and diastolic BP, was similar to invasive BP(RAD) during postoperative observation following CEA, based on AAMI criteria. However, as systolic BP is currently leading in postoperative monitoring to adjust BP therapy on, BP(CS) is not a reliable alternative for BP(RAD.) |
format | Online Article Text |
id | pubmed-8807161 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-88071612022-02-02 The ClearSight System for Postoperative Arterial Blood Pressure Monitoring After Carotid Endarterectomy: A Validation Study Fassaert, Leonie M M Plate, Joost D J Westerink, Jan Immink, Rogier V de Borst, Gert J Am J Hypertens Original Articles BACKGROUND: The majority of postoperative events in patients undergoing carotid endarterectomy (CEA) are of hemodynamic origin, requiring preventive strict postoperative arterial blood pressure (BP) control. This study aimed to assess whether BP monitoring with noninvasive beat-to-beat ClearSight finger BP (BP(CS)) can replace invasive beat-to-beat radial artery BP (BP(RAD)) in the postoperative phase. METHODS: This study was a single-center clinical validation study using a prespecified study protocol. In 48 patients with symptomatic carotid artery stenosis, BP(CS) and BP(RAD) were monitored ipsilateral in a simultaneous manner during a 6-hour period on the recovery unit following CEA. Primary endpoints were accuracy and precision of BP derived by ClearSight (Edward Lifesciences, Irvine, CA) vs. the reference standard (Arbocath 20 G, Hospira, Lake Forest, IL) to investigate if BP(CS) is a reliable noninvasive alternative for BP monitoring postoperatively in CEA patients. Validation was guided by the standard set by the Association for Advancement of Medical Instrumentation (AAMI), considering a BP-monitor adequate when bias (precision) is <5 (8) mm Hg. Secondary endpoint was percentage under- and overtreatment, defined as exceedance of individual postoperative systolic BP threshold by BP(RAD) or BP(CS) in contrast to BP(CS) or BP(RAD), respectively. RESULTS: The bias (precision) of BP(CS) compared to BP(RAD) was −10 (13.6), 8 (7.2) and 4 (7.8) mm Hg for systolic, diastolic and mean arterial pressure (MAP), respectively. Based on BP(CS), undertreatment was 5.6% and overtreatment was 2.4%; however, percentages of undertreatment quadrupled for lower systolic BP thresholds. CONCLUSIONS: Noninvasive MAP, but not systolic and diastolic BP, was similar to invasive BP(RAD) during postoperative observation following CEA, based on AAMI criteria. However, as systolic BP is currently leading in postoperative monitoring to adjust BP therapy on, BP(CS) is not a reliable alternative for BP(RAD.) Oxford University Press 2021-09-10 /pmc/articles/PMC8807161/ /pubmed/34505631 http://dx.doi.org/10.1093/ajh/hpab140 Text en © The Author(s) 2021. Published by Oxford University Press on behalf of American Journal of Hypertension, Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Original Articles Fassaert, Leonie M M Plate, Joost D J Westerink, Jan Immink, Rogier V de Borst, Gert J The ClearSight System for Postoperative Arterial Blood Pressure Monitoring After Carotid Endarterectomy: A Validation Study |
title | The ClearSight System for Postoperative Arterial Blood Pressure Monitoring After Carotid Endarterectomy: A Validation Study |
title_full | The ClearSight System for Postoperative Arterial Blood Pressure Monitoring After Carotid Endarterectomy: A Validation Study |
title_fullStr | The ClearSight System for Postoperative Arterial Blood Pressure Monitoring After Carotid Endarterectomy: A Validation Study |
title_full_unstemmed | The ClearSight System for Postoperative Arterial Blood Pressure Monitoring After Carotid Endarterectomy: A Validation Study |
title_short | The ClearSight System for Postoperative Arterial Blood Pressure Monitoring After Carotid Endarterectomy: A Validation Study |
title_sort | clearsight system for postoperative arterial blood pressure monitoring after carotid endarterectomy: a validation study |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8807161/ https://www.ncbi.nlm.nih.gov/pubmed/34505631 http://dx.doi.org/10.1093/ajh/hpab140 |
work_keys_str_mv | AT fassaertleoniemm theclearsightsystemforpostoperativearterialbloodpressuremonitoringaftercarotidendarterectomyavalidationstudy AT platejoostdj theclearsightsystemforpostoperativearterialbloodpressuremonitoringaftercarotidendarterectomyavalidationstudy AT westerinkjan theclearsightsystemforpostoperativearterialbloodpressuremonitoringaftercarotidendarterectomyavalidationstudy AT imminkrogierv theclearsightsystemforpostoperativearterialbloodpressuremonitoringaftercarotidendarterectomyavalidationstudy AT deborstgertj theclearsightsystemforpostoperativearterialbloodpressuremonitoringaftercarotidendarterectomyavalidationstudy AT fassaertleoniemm clearsightsystemforpostoperativearterialbloodpressuremonitoringaftercarotidendarterectomyavalidationstudy AT platejoostdj clearsightsystemforpostoperativearterialbloodpressuremonitoringaftercarotidendarterectomyavalidationstudy AT westerinkjan clearsightsystemforpostoperativearterialbloodpressuremonitoringaftercarotidendarterectomyavalidationstudy AT imminkrogierv clearsightsystemforpostoperativearterialbloodpressuremonitoringaftercarotidendarterectomyavalidationstudy AT deborstgertj clearsightsystemforpostoperativearterialbloodpressuremonitoringaftercarotidendarterectomyavalidationstudy |