Three-Dimensional Patient Specific Instrumentation and Cutting Guide for Medial Closing Wedge High Tibial Osteotomy to Correct Valgus Malalignment
Achievement of appropriate mechanical knee alignment is crucial to ensure optimal clinical outcomes following osteotomy procedures about the knee. The use of patient-specific instrumentation (PSI) to assist in preoperative planning and intraoperative realignment has gained increasing popularity. The...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8807722/ https://www.ncbi.nlm.nih.gov/pubmed/35127424 http://dx.doi.org/10.1016/j.eats.2021.08.030 |
_version_ | 1784643744608288768 |
---|---|
author | Fortier, Luc M. Gursoy, Safa Knapik, Derrick M. Chahla, Jorge |
author_facet | Fortier, Luc M. Gursoy, Safa Knapik, Derrick M. Chahla, Jorge |
author_sort | Fortier, Luc M. |
collection | PubMed |
description | Achievement of appropriate mechanical knee alignment is crucial to ensure optimal clinical outcomes following osteotomy procedures about the knee. The use of patient-specific instrumentation (PSI) to assist in preoperative planning and intraoperative realignment has gained increasing popularity. The purpose of this article is to describe a surgical technique involving a medial closing wedge high tibial osteotomy performed using three-dimensional (3D) PSI and cutting guide to revise residual valgus deformity following failed distal femoral osteotomy. The correction angle, 3D position of the hinge and wedge, as well as final plate and screw position are planned preoperatively using virtual software and computed tomography imaging to allow precise surgical execution. |
format | Online Article Text |
id | pubmed-8807722 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-88077222022-02-04 Three-Dimensional Patient Specific Instrumentation and Cutting Guide for Medial Closing Wedge High Tibial Osteotomy to Correct Valgus Malalignment Fortier, Luc M. Gursoy, Safa Knapik, Derrick M. Chahla, Jorge Arthrosc Tech Technical Note Achievement of appropriate mechanical knee alignment is crucial to ensure optimal clinical outcomes following osteotomy procedures about the knee. The use of patient-specific instrumentation (PSI) to assist in preoperative planning and intraoperative realignment has gained increasing popularity. The purpose of this article is to describe a surgical technique involving a medial closing wedge high tibial osteotomy performed using three-dimensional (3D) PSI and cutting guide to revise residual valgus deformity following failed distal femoral osteotomy. The correction angle, 3D position of the hinge and wedge, as well as final plate and screw position are planned preoperatively using virtual software and computed tomography imaging to allow precise surgical execution. Elsevier 2021-12-20 /pmc/articles/PMC8807722/ /pubmed/35127424 http://dx.doi.org/10.1016/j.eats.2021.08.030 Text en © 2021 Published by Elsevier on behalf of the Arthroscopy Association of North America. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Technical Note Fortier, Luc M. Gursoy, Safa Knapik, Derrick M. Chahla, Jorge Three-Dimensional Patient Specific Instrumentation and Cutting Guide for Medial Closing Wedge High Tibial Osteotomy to Correct Valgus Malalignment |
title | Three-Dimensional Patient Specific Instrumentation and Cutting Guide for Medial Closing Wedge High Tibial Osteotomy to Correct Valgus Malalignment |
title_full | Three-Dimensional Patient Specific Instrumentation and Cutting Guide for Medial Closing Wedge High Tibial Osteotomy to Correct Valgus Malalignment |
title_fullStr | Three-Dimensional Patient Specific Instrumentation and Cutting Guide for Medial Closing Wedge High Tibial Osteotomy to Correct Valgus Malalignment |
title_full_unstemmed | Three-Dimensional Patient Specific Instrumentation and Cutting Guide for Medial Closing Wedge High Tibial Osteotomy to Correct Valgus Malalignment |
title_short | Three-Dimensional Patient Specific Instrumentation and Cutting Guide for Medial Closing Wedge High Tibial Osteotomy to Correct Valgus Malalignment |
title_sort | three-dimensional patient specific instrumentation and cutting guide for medial closing wedge high tibial osteotomy to correct valgus malalignment |
topic | Technical Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8807722/ https://www.ncbi.nlm.nih.gov/pubmed/35127424 http://dx.doi.org/10.1016/j.eats.2021.08.030 |
work_keys_str_mv | AT fortierlucm threedimensionalpatientspecificinstrumentationandcuttingguideformedialclosingwedgehightibialosteotomytocorrectvalgusmalalignment AT gursoysafa threedimensionalpatientspecificinstrumentationandcuttingguideformedialclosingwedgehightibialosteotomytocorrectvalgusmalalignment AT knapikderrickm threedimensionalpatientspecificinstrumentationandcuttingguideformedialclosingwedgehightibialosteotomytocorrectvalgusmalalignment AT chahlajorge threedimensionalpatientspecificinstrumentationandcuttingguideformedialclosingwedgehightibialosteotomytocorrectvalgusmalalignment |