Cargando…

Effect of Joint Use of External Minifixator and Titanium Lockplate on Total Active Motion Range and Hand Function Recovery in Comminuted Metacarpal and Phalanx Fracture Patients

OBJECTIVE: To explore the effect of joint use of external minifixator and titanium lockplate on total active motion (TAM) range and hand function recovery in comminuted metacarpal and phalanx fracture patients. METHODS: The medical data of 70 patients with comminuted metacarpal and phalanx fracture...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Yao, Zhang, Hongwei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8808207/
https://www.ncbi.nlm.nih.gov/pubmed/35126920
http://dx.doi.org/10.1155/2022/3566364
_version_ 1784643836551626752
author Li, Yao
Zhang, Hongwei
author_facet Li, Yao
Zhang, Hongwei
author_sort Li, Yao
collection PubMed
description OBJECTIVE: To explore the effect of joint use of external minifixator and titanium lockplate on total active motion (TAM) range and hand function recovery in comminuted metacarpal and phalanx fracture patients. METHODS: The medical data of 70 patients with comminuted metacarpal and phalanx fracture treated in our hospital from June 2017 to June 2020 were screened for the retrospective study, and the patients were divided into the control group (Kirschner wire internal fixation) and the study group (an external minifixator with titanium lockplate) according to the treatment modalities, with 35 cases each. After treatment, the clinical efficacy of patients was compared between the two groups. RESULTS: No between-group differences in patients' general data were observed (P > 0.05); the time for hospital stay and fracture healing was obviously shorter in the study group than that in the control group (P < 0.05); after treatment, the study group obtained significantly higher TAM range good rate (P < 0.05), significantly higher Carroll hand function test pass rate (P < 0.05), and obviously better grip strength of both hands and score on digital opposition of thumb than those in the control group (P < 0.05); and after surgery, the study group had significantly lower incidence rates of complications such as infection, local inflammation, displacement of bone, and adhesion of tendon that those in the control group (P < 0.05). CONCLUSION: Joint use of an external minifixator and titanium lockplate can effectively promote the TAM range and accelerate hand function recovery for comminuted metacarpal and phalanx fracture patients and is conducive to reducing the incidence of postoperative complications, which is safe and has significant efficacy.
format Online
Article
Text
id pubmed-8808207
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-88082072022-02-03 Effect of Joint Use of External Minifixator and Titanium Lockplate on Total Active Motion Range and Hand Function Recovery in Comminuted Metacarpal and Phalanx Fracture Patients Li, Yao Zhang, Hongwei J Healthc Eng Research Article OBJECTIVE: To explore the effect of joint use of external minifixator and titanium lockplate on total active motion (TAM) range and hand function recovery in comminuted metacarpal and phalanx fracture patients. METHODS: The medical data of 70 patients with comminuted metacarpal and phalanx fracture treated in our hospital from June 2017 to June 2020 were screened for the retrospective study, and the patients were divided into the control group (Kirschner wire internal fixation) and the study group (an external minifixator with titanium lockplate) according to the treatment modalities, with 35 cases each. After treatment, the clinical efficacy of patients was compared between the two groups. RESULTS: No between-group differences in patients' general data were observed (P > 0.05); the time for hospital stay and fracture healing was obviously shorter in the study group than that in the control group (P < 0.05); after treatment, the study group obtained significantly higher TAM range good rate (P < 0.05), significantly higher Carroll hand function test pass rate (P < 0.05), and obviously better grip strength of both hands and score on digital opposition of thumb than those in the control group (P < 0.05); and after surgery, the study group had significantly lower incidence rates of complications such as infection, local inflammation, displacement of bone, and adhesion of tendon that those in the control group (P < 0.05). CONCLUSION: Joint use of an external minifixator and titanium lockplate can effectively promote the TAM range and accelerate hand function recovery for comminuted metacarpal and phalanx fracture patients and is conducive to reducing the incidence of postoperative complications, which is safe and has significant efficacy. Hindawi 2022-01-25 /pmc/articles/PMC8808207/ /pubmed/35126920 http://dx.doi.org/10.1155/2022/3566364 Text en Copyright © 2022 Yao Li and Hongwei Zhang. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Li, Yao
Zhang, Hongwei
Effect of Joint Use of External Minifixator and Titanium Lockplate on Total Active Motion Range and Hand Function Recovery in Comminuted Metacarpal and Phalanx Fracture Patients
title Effect of Joint Use of External Minifixator and Titanium Lockplate on Total Active Motion Range and Hand Function Recovery in Comminuted Metacarpal and Phalanx Fracture Patients
title_full Effect of Joint Use of External Minifixator and Titanium Lockplate on Total Active Motion Range and Hand Function Recovery in Comminuted Metacarpal and Phalanx Fracture Patients
title_fullStr Effect of Joint Use of External Minifixator and Titanium Lockplate on Total Active Motion Range and Hand Function Recovery in Comminuted Metacarpal and Phalanx Fracture Patients
title_full_unstemmed Effect of Joint Use of External Minifixator and Titanium Lockplate on Total Active Motion Range and Hand Function Recovery in Comminuted Metacarpal and Phalanx Fracture Patients
title_short Effect of Joint Use of External Minifixator and Titanium Lockplate on Total Active Motion Range and Hand Function Recovery in Comminuted Metacarpal and Phalanx Fracture Patients
title_sort effect of joint use of external minifixator and titanium lockplate on total active motion range and hand function recovery in comminuted metacarpal and phalanx fracture patients
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8808207/
https://www.ncbi.nlm.nih.gov/pubmed/35126920
http://dx.doi.org/10.1155/2022/3566364
work_keys_str_mv AT liyao effectofjointuseofexternalminifixatorandtitaniumlockplateontotalactivemotionrangeandhandfunctionrecoveryincomminutedmetacarpalandphalanxfracturepatients
AT zhanghongwei effectofjointuseofexternalminifixatorandtitaniumlockplateontotalactivemotionrangeandhandfunctionrecoveryincomminutedmetacarpalandphalanxfracturepatients