Cargando…

Novel Sutureless Scleral Fixated IOL for Inadequate or Absent Capsular Support

PURPOSE: To evaluate the clinical outcome and safety profile of a new sutureless scleral fixation (SSF) technique using a single-piece foldable acrylic Carlevale intraocular lens. METHODS: In this case study, 27 eyes of 27 patients were implanted with an SSF single-piece IOL because of inadequate or...

Descripción completa

Detalles Bibliográficos
Autores principales: Sidiropoulos, Georgios, Siskou, Elisabeth, Koronis, Spyridon, Tranos, Paris, Gatzioufas, Zisis, Balidis, Miltos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8808236/
https://www.ncbi.nlm.nih.gov/pubmed/35127155
http://dx.doi.org/10.1155/2022/2161003
_version_ 1784643843682992128
author Sidiropoulos, Georgios
Siskou, Elisabeth
Koronis, Spyridon
Tranos, Paris
Gatzioufas, Zisis
Balidis, Miltos
author_facet Sidiropoulos, Georgios
Siskou, Elisabeth
Koronis, Spyridon
Tranos, Paris
Gatzioufas, Zisis
Balidis, Miltos
author_sort Sidiropoulos, Georgios
collection PubMed
description PURPOSE: To evaluate the clinical outcome and safety profile of a new sutureless scleral fixation (SSF) technique using a single-piece foldable acrylic Carlevale intraocular lens. METHODS: In this case study, 27 eyes of 27 patients were implanted with an SSF single-piece IOL because of inadequate or absent capsular support. The hand-shake technique used during surgery was combined with the creation of scleral pockets in order to secure the IOL haptics. The BCVA was evaluated in the 1st and 6th month in every patient and in the 12th and 24th months, when possible. Also, we evaluated the improvement achieved in spherical equivalent values from baseline to the 6th month after the procedure. Intraoperative and postoperative complications were assessed. RESULTS: The mean age was 69.1 ± 14.9 years, and the mean follow-up was 13.6 ± 4.8 months. Indications of scleral-fixated IOL included dislocated posterior chamber IOL (40.7%), dislocated anterior chamber IOL (11.1%), subluxated traumatic cataract (18.5%), subluxated nontraumatic cataract (18.5%), and aphakia (11.1%). Concurrent PPV was performed on eight of the eyes (32%). The mean preoperative logMAR BCVA increased from 0.85 ± 0.59 baseline to 0.44 ± 0.30 one month after surgery (p < 0.01) and 0.36 ± 0.34 (p < 0.003) six months after surgery. The baseline refractive status expressed in SE was 4.3 ± 6.4 D, and the postoperative status was −0.5 ± 0.99 D. Postoperative complications included vitreous hemorrhage (7.4%), hypotony (7.4%), transient IOP elevation (3.7%), and postoperative cystoid macular oedema (3.7%). The IOL was very well centered and stable in every case during the follow-up period. CONCLUSION: The use of the SSF technique with implantation of a single-piece foldable acrylic Carlevale IOL seems to be a safe and effective alternative method that provides good preliminary results in cases where capsular support is inadequate or absent. Long-term stability results would be required to evaluate the benefit of this novel surgical approach in order to compare it with other existing methods.
format Online
Article
Text
id pubmed-8808236
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-88082362022-02-03 Novel Sutureless Scleral Fixated IOL for Inadequate or Absent Capsular Support Sidiropoulos, Georgios Siskou, Elisabeth Koronis, Spyridon Tranos, Paris Gatzioufas, Zisis Balidis, Miltos J Ophthalmol Research Article PURPOSE: To evaluate the clinical outcome and safety profile of a new sutureless scleral fixation (SSF) technique using a single-piece foldable acrylic Carlevale intraocular lens. METHODS: In this case study, 27 eyes of 27 patients were implanted with an SSF single-piece IOL because of inadequate or absent capsular support. The hand-shake technique used during surgery was combined with the creation of scleral pockets in order to secure the IOL haptics. The BCVA was evaluated in the 1st and 6th month in every patient and in the 12th and 24th months, when possible. Also, we evaluated the improvement achieved in spherical equivalent values from baseline to the 6th month after the procedure. Intraoperative and postoperative complications were assessed. RESULTS: The mean age was 69.1 ± 14.9 years, and the mean follow-up was 13.6 ± 4.8 months. Indications of scleral-fixated IOL included dislocated posterior chamber IOL (40.7%), dislocated anterior chamber IOL (11.1%), subluxated traumatic cataract (18.5%), subluxated nontraumatic cataract (18.5%), and aphakia (11.1%). Concurrent PPV was performed on eight of the eyes (32%). The mean preoperative logMAR BCVA increased from 0.85 ± 0.59 baseline to 0.44 ± 0.30 one month after surgery (p < 0.01) and 0.36 ± 0.34 (p < 0.003) six months after surgery. The baseline refractive status expressed in SE was 4.3 ± 6.4 D, and the postoperative status was −0.5 ± 0.99 D. Postoperative complications included vitreous hemorrhage (7.4%), hypotony (7.4%), transient IOP elevation (3.7%), and postoperative cystoid macular oedema (3.7%). The IOL was very well centered and stable in every case during the follow-up period. CONCLUSION: The use of the SSF technique with implantation of a single-piece foldable acrylic Carlevale IOL seems to be a safe and effective alternative method that provides good preliminary results in cases where capsular support is inadequate or absent. Long-term stability results would be required to evaluate the benefit of this novel surgical approach in order to compare it with other existing methods. Hindawi 2022-01-25 /pmc/articles/PMC8808236/ /pubmed/35127155 http://dx.doi.org/10.1155/2022/2161003 Text en Copyright © 2022 Georgios Sidiropoulos et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Sidiropoulos, Georgios
Siskou, Elisabeth
Koronis, Spyridon
Tranos, Paris
Gatzioufas, Zisis
Balidis, Miltos
Novel Sutureless Scleral Fixated IOL for Inadequate or Absent Capsular Support
title Novel Sutureless Scleral Fixated IOL for Inadequate or Absent Capsular Support
title_full Novel Sutureless Scleral Fixated IOL for Inadequate or Absent Capsular Support
title_fullStr Novel Sutureless Scleral Fixated IOL for Inadequate or Absent Capsular Support
title_full_unstemmed Novel Sutureless Scleral Fixated IOL for Inadequate or Absent Capsular Support
title_short Novel Sutureless Scleral Fixated IOL for Inadequate or Absent Capsular Support
title_sort novel sutureless scleral fixated iol for inadequate or absent capsular support
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8808236/
https://www.ncbi.nlm.nih.gov/pubmed/35127155
http://dx.doi.org/10.1155/2022/2161003
work_keys_str_mv AT sidiropoulosgeorgios novelsuturelessscleralfixatediolforinadequateorabsentcapsularsupport
AT siskouelisabeth novelsuturelessscleralfixatediolforinadequateorabsentcapsularsupport
AT koronisspyridon novelsuturelessscleralfixatediolforinadequateorabsentcapsularsupport
AT tranosparis novelsuturelessscleralfixatediolforinadequateorabsentcapsularsupport
AT gatzioufaszisis novelsuturelessscleralfixatediolforinadequateorabsentcapsularsupport
AT balidismiltos novelsuturelessscleralfixatediolforinadequateorabsentcapsularsupport