Cargando…

Reliability and agreement of point-of-care carotid artery examinations by experts using hand-held ultrasound devices in patients with ischaemic stroke or transitory ischaemic attack

OBJECTIVES: To investigate the reliability and agreement of hand-held ultrasound devices (HUDs) compared with conventional duplex ultrasound (HIGH) in examination for carotid stenosis in patients with suspected transitory ischaemic attack (TIA) or ischaemic stroke. METHODS: Cardiologists, experience...

Descripción completa

Detalles Bibliográficos
Autores principales: Saxhaug, Lars Mølgaard, Graven, Torbjorn, Olsen, Øystein, Kleinau, Jens Olaf, Skjetne, Kyrre, Ellekjær, Hanne, Dalen, Havard
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8808450/
https://www.ncbi.nlm.nih.gov/pubmed/35105719
http://dx.doi.org/10.1136/openhrt-2021-001917
_version_ 1784643890509250560
author Saxhaug, Lars Mølgaard
Graven, Torbjorn
Olsen, Øystein
Kleinau, Jens Olaf
Skjetne, Kyrre
Ellekjær, Hanne
Dalen, Havard
author_facet Saxhaug, Lars Mølgaard
Graven, Torbjorn
Olsen, Øystein
Kleinau, Jens Olaf
Skjetne, Kyrre
Ellekjær, Hanne
Dalen, Havard
author_sort Saxhaug, Lars Mølgaard
collection PubMed
description OBJECTIVES: To investigate the reliability and agreement of hand-held ultrasound devices (HUDs) compared with conventional duplex ultrasound (HIGH) in examination for carotid stenosis in patients with suspected transitory ischaemic attack (TIA) or ischaemic stroke. METHODS: Cardiologists, experienced in carotid ultrasound, examined patients admitted to a community hospital with suspected stroke or TIA. Patients were first examined by an HUD and second by HIGH as per usual care. Different operators performed HUD and HIGH blinded to each other. On clinical discretion, CT angiography (CTA) was performed, and analysed by a radiologist blinded to the results from the ultrasound. RESULTS: Of 80 patients included, 9 (11%) were found to have >50% internal carotid artery (ICA) stenosis on reference examination. Agreement for classification of the degree of ICA stenosis was good for HUD versus HIGH (weighted Kappa 0.76) and HUD versus CTA (weighted Kappa 0.66). Agreement between HUD and HIGH examinations was excellent when ICA was classified as <50% diameter stenosis by HUD (99% agreement), but significantly lower when ICA diameter stenosis was classified as >50% by HUD (OR 0.15, 95% CI 0.06 to 0.42). Overall, HUD tended to overestimate the degree of carotid stenoses rather than underestimate (p=0.048). CONCLUSION: Hand-held carotid ultrasound performed by experts demonstrated good agreement with conventional duplex ultrasound. The use of HUDs was reliable for ruling out significant carotid artery disease, but less reliable for ruling in significant disease.
format Online
Article
Text
id pubmed-8808450
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-88084502022-02-09 Reliability and agreement of point-of-care carotid artery examinations by experts using hand-held ultrasound devices in patients with ischaemic stroke or transitory ischaemic attack Saxhaug, Lars Mølgaard Graven, Torbjorn Olsen, Øystein Kleinau, Jens Olaf Skjetne, Kyrre Ellekjær, Hanne Dalen, Havard Open Heart Special Populations OBJECTIVES: To investigate the reliability and agreement of hand-held ultrasound devices (HUDs) compared with conventional duplex ultrasound (HIGH) in examination for carotid stenosis in patients with suspected transitory ischaemic attack (TIA) or ischaemic stroke. METHODS: Cardiologists, experienced in carotid ultrasound, examined patients admitted to a community hospital with suspected stroke or TIA. Patients were first examined by an HUD and second by HIGH as per usual care. Different operators performed HUD and HIGH blinded to each other. On clinical discretion, CT angiography (CTA) was performed, and analysed by a radiologist blinded to the results from the ultrasound. RESULTS: Of 80 patients included, 9 (11%) were found to have >50% internal carotid artery (ICA) stenosis on reference examination. Agreement for classification of the degree of ICA stenosis was good for HUD versus HIGH (weighted Kappa 0.76) and HUD versus CTA (weighted Kappa 0.66). Agreement between HUD and HIGH examinations was excellent when ICA was classified as <50% diameter stenosis by HUD (99% agreement), but significantly lower when ICA diameter stenosis was classified as >50% by HUD (OR 0.15, 95% CI 0.06 to 0.42). Overall, HUD tended to overestimate the degree of carotid stenoses rather than underestimate (p=0.048). CONCLUSION: Hand-held carotid ultrasound performed by experts demonstrated good agreement with conventional duplex ultrasound. The use of HUDs was reliable for ruling out significant carotid artery disease, but less reliable for ruling in significant disease. BMJ Publishing Group 2022-02-01 /pmc/articles/PMC8808450/ /pubmed/35105719 http://dx.doi.org/10.1136/openhrt-2021-001917 Text en © Author(s) (or their employer(s)) 2022. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) .
spellingShingle Special Populations
Saxhaug, Lars Mølgaard
Graven, Torbjorn
Olsen, Øystein
Kleinau, Jens Olaf
Skjetne, Kyrre
Ellekjær, Hanne
Dalen, Havard
Reliability and agreement of point-of-care carotid artery examinations by experts using hand-held ultrasound devices in patients with ischaemic stroke or transitory ischaemic attack
title Reliability and agreement of point-of-care carotid artery examinations by experts using hand-held ultrasound devices in patients with ischaemic stroke or transitory ischaemic attack
title_full Reliability and agreement of point-of-care carotid artery examinations by experts using hand-held ultrasound devices in patients with ischaemic stroke or transitory ischaemic attack
title_fullStr Reliability and agreement of point-of-care carotid artery examinations by experts using hand-held ultrasound devices in patients with ischaemic stroke or transitory ischaemic attack
title_full_unstemmed Reliability and agreement of point-of-care carotid artery examinations by experts using hand-held ultrasound devices in patients with ischaemic stroke or transitory ischaemic attack
title_short Reliability and agreement of point-of-care carotid artery examinations by experts using hand-held ultrasound devices in patients with ischaemic stroke or transitory ischaemic attack
title_sort reliability and agreement of point-of-care carotid artery examinations by experts using hand-held ultrasound devices in patients with ischaemic stroke or transitory ischaemic attack
topic Special Populations
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8808450/
https://www.ncbi.nlm.nih.gov/pubmed/35105719
http://dx.doi.org/10.1136/openhrt-2021-001917
work_keys_str_mv AT saxhauglarsmølgaard reliabilityandagreementofpointofcarecarotidarteryexaminationsbyexpertsusinghandheldultrasounddevicesinpatientswithischaemicstrokeortransitoryischaemicattack
AT graventorbjorn reliabilityandagreementofpointofcarecarotidarteryexaminationsbyexpertsusinghandheldultrasounddevicesinpatientswithischaemicstrokeortransitoryischaemicattack
AT olsenøystein reliabilityandagreementofpointofcarecarotidarteryexaminationsbyexpertsusinghandheldultrasounddevicesinpatientswithischaemicstrokeortransitoryischaemicattack
AT kleinaujensolaf reliabilityandagreementofpointofcarecarotidarteryexaminationsbyexpertsusinghandheldultrasounddevicesinpatientswithischaemicstrokeortransitoryischaemicattack
AT skjetnekyrre reliabilityandagreementofpointofcarecarotidarteryexaminationsbyexpertsusinghandheldultrasounddevicesinpatientswithischaemicstrokeortransitoryischaemicattack
AT ellekjærhanne reliabilityandagreementofpointofcarecarotidarteryexaminationsbyexpertsusinghandheldultrasounddevicesinpatientswithischaemicstrokeortransitoryischaemicattack
AT dalenhavard reliabilityandagreementofpointofcarecarotidarteryexaminationsbyexpertsusinghandheldultrasounddevicesinpatientswithischaemicstrokeortransitoryischaemicattack