Cargando…

Analysis of measurement changes in pelvic incidence according to pelvic rotation using a three-dimensional model

BACKGROUND: Pelvic incidence (PI) is used as a key parameter in surgical correction of adult spinal deformity (ASD). However, reflecting the exact center or inclination of the three-dimensional anatomical structures on the two-dimensional (2D) sagittal radiographs is limited, resulting in measuremen...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Ki Young, Lee, Jung-Hee, Im, Sang-Kyu, Lee, Won Young
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8808983/
https://www.ncbi.nlm.nih.gov/pubmed/35109846
http://dx.doi.org/10.1186/s12891-022-05063-9
_version_ 1784643927938170880
author Lee, Ki Young
Lee, Jung-Hee
Im, Sang-Kyu
Lee, Won Young
author_facet Lee, Ki Young
Lee, Jung-Hee
Im, Sang-Kyu
Lee, Won Young
author_sort Lee, Ki Young
collection PubMed
description BACKGROUND: Pelvic incidence (PI) is used as a key parameter in surgical correction of adult spinal deformity (ASD). However, reflecting the exact center or inclination of the three-dimensional anatomical structures on the two-dimensional (2D) sagittal radiographs is limited, resulting in measurement errors. Therefore, we evaluated whether there is a change in PI measurement according to the actual rotation of the pelvis, and conducted a study on a more accurate method for PI measurement using 2D sagittal radiographs. METHODS: From 2014 to 2015, the data of 30 patients who visited our outpatient clinic were analyzed retrospectively. CT scans including those of the lower lumbar spine, pelvis, and both femurs in the DICOM format were imported to Mimics Research 17.0 (Materialise NV, Belgium), SolidWorks (Dassault systems, France), and AutoCAD 2014 (AUTODESK, US). The changes in PI according to vertical and horizontal pelvic rotations were evaluated. RESULTS: The average PIs according to the horizontal pelvic rotations measured on AutoCAD with 0°, 5°, 10°, 15°, 20°, 25°, 30°, 35°, and 40° were 48.8°, 48.7°, 48.3°, 47.8°, 46.9°, 45.6°, 44.0°, 42.2°, and 39.9°, respectively. The PI with an acceptable error of 6° on radiographs was 35° in the horizontal pelvic rotation. The average PIs according to the vertical pelvic rotations measured on AutoCAD with 0°, 5°, 10°, 15°, 20°, 25°, 30°, 35°, and 40° were 48.8°, 49.0°, 49.5°, 50.2°, 51.3°, 52.7°, 54.4°, 56.6°, and 59.4°, respectively. The PI with an acceptable error of 6° on radiographs was 30° in the vertical pelvic rotation. CONCLUSIONS: This study revealed that the PI value could differ from the actual anatomical value due to the horizontal and vertical rotation of the pelvis while acquiring the radiograph. Regarding whole-spine lateral radiographs, errors in PI measurement may occur due to pelvic rotation or nonvertical projection of X-rays. In the standing pelvic lateral radiographs, ensuring superposition of the femoral heads at the center and obtaining the straight sacral endplate by referring to CT or magnetic resonance imaging would be a more accurate measurement method to define PI.
format Online
Article
Text
id pubmed-8808983
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-88089832022-02-03 Analysis of measurement changes in pelvic incidence according to pelvic rotation using a three-dimensional model Lee, Ki Young Lee, Jung-Hee Im, Sang-Kyu Lee, Won Young BMC Musculoskelet Disord Research BACKGROUND: Pelvic incidence (PI) is used as a key parameter in surgical correction of adult spinal deformity (ASD). However, reflecting the exact center or inclination of the three-dimensional anatomical structures on the two-dimensional (2D) sagittal radiographs is limited, resulting in measurement errors. Therefore, we evaluated whether there is a change in PI measurement according to the actual rotation of the pelvis, and conducted a study on a more accurate method for PI measurement using 2D sagittal radiographs. METHODS: From 2014 to 2015, the data of 30 patients who visited our outpatient clinic were analyzed retrospectively. CT scans including those of the lower lumbar spine, pelvis, and both femurs in the DICOM format were imported to Mimics Research 17.0 (Materialise NV, Belgium), SolidWorks (Dassault systems, France), and AutoCAD 2014 (AUTODESK, US). The changes in PI according to vertical and horizontal pelvic rotations were evaluated. RESULTS: The average PIs according to the horizontal pelvic rotations measured on AutoCAD with 0°, 5°, 10°, 15°, 20°, 25°, 30°, 35°, and 40° were 48.8°, 48.7°, 48.3°, 47.8°, 46.9°, 45.6°, 44.0°, 42.2°, and 39.9°, respectively. The PI with an acceptable error of 6° on radiographs was 35° in the horizontal pelvic rotation. The average PIs according to the vertical pelvic rotations measured on AutoCAD with 0°, 5°, 10°, 15°, 20°, 25°, 30°, 35°, and 40° were 48.8°, 49.0°, 49.5°, 50.2°, 51.3°, 52.7°, 54.4°, 56.6°, and 59.4°, respectively. The PI with an acceptable error of 6° on radiographs was 30° in the vertical pelvic rotation. CONCLUSIONS: This study revealed that the PI value could differ from the actual anatomical value due to the horizontal and vertical rotation of the pelvis while acquiring the radiograph. Regarding whole-spine lateral radiographs, errors in PI measurement may occur due to pelvic rotation or nonvertical projection of X-rays. In the standing pelvic lateral radiographs, ensuring superposition of the femoral heads at the center and obtaining the straight sacral endplate by referring to CT or magnetic resonance imaging would be a more accurate measurement method to define PI. BioMed Central 2022-02-02 /pmc/articles/PMC8808983/ /pubmed/35109846 http://dx.doi.org/10.1186/s12891-022-05063-9 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Lee, Ki Young
Lee, Jung-Hee
Im, Sang-Kyu
Lee, Won Young
Analysis of measurement changes in pelvic incidence according to pelvic rotation using a three-dimensional model
title Analysis of measurement changes in pelvic incidence according to pelvic rotation using a three-dimensional model
title_full Analysis of measurement changes in pelvic incidence according to pelvic rotation using a three-dimensional model
title_fullStr Analysis of measurement changes in pelvic incidence according to pelvic rotation using a three-dimensional model
title_full_unstemmed Analysis of measurement changes in pelvic incidence according to pelvic rotation using a three-dimensional model
title_short Analysis of measurement changes in pelvic incidence according to pelvic rotation using a three-dimensional model
title_sort analysis of measurement changes in pelvic incidence according to pelvic rotation using a three-dimensional model
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8808983/
https://www.ncbi.nlm.nih.gov/pubmed/35109846
http://dx.doi.org/10.1186/s12891-022-05063-9
work_keys_str_mv AT leekiyoung analysisofmeasurementchangesinpelvicincidenceaccordingtopelvicrotationusingathreedimensionalmodel
AT leejunghee analysisofmeasurementchangesinpelvicincidenceaccordingtopelvicrotationusingathreedimensionalmodel
AT imsangkyu analysisofmeasurementchangesinpelvicincidenceaccordingtopelvicrotationusingathreedimensionalmodel
AT leewonyoung analysisofmeasurementchangesinpelvicincidenceaccordingtopelvicrotationusingathreedimensionalmodel