Continuous Monitoring of Mental Load During Virtual Simulator Training for Laparoscopic Surgery Reflects Laparoscopic Dexterity: A Comparative Study Using a Novel Wireless Device

INTRODUCTION: Cognitive Load Theory (CLT) relates to the efficiency with which individuals manipulate the limited capacity of working memory load. Repeated training generally results in individual performance increase and cognitive load decrease, as measured by both behavioral and neuroimaging metho...

Descripción completa

Detalles Bibliográficos
Autores principales: Maimon, Neta B., Bez, Maxim, Drobot, Denis, Molcho, Lior, Intrator, Nathan, Kakiashvilli, Eli, Bickel, Amitai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8811150/
https://www.ncbi.nlm.nih.gov/pubmed/35126032
http://dx.doi.org/10.3389/fnins.2021.694010
_version_ 1784644368677732352
author Maimon, Neta B.
Bez, Maxim
Drobot, Denis
Molcho, Lior
Intrator, Nathan
Kakiashvilli, Eli
Bickel, Amitai
author_facet Maimon, Neta B.
Bez, Maxim
Drobot, Denis
Molcho, Lior
Intrator, Nathan
Kakiashvilli, Eli
Bickel, Amitai
author_sort Maimon, Neta B.
collection PubMed
description INTRODUCTION: Cognitive Load Theory (CLT) relates to the efficiency with which individuals manipulate the limited capacity of working memory load. Repeated training generally results in individual performance increase and cognitive load decrease, as measured by both behavioral and neuroimaging methods. One of the known biomarkers for cognitive load is frontal theta band, measured by an EEG. Simulation-based training is an effective tool for acquiring practical skills, specifically to train new surgeons in a controlled and hazard-free environment. Measuring the cognitive load of young surgeons undergoing such training can help to determine whether they are ready to take part in a real surgery. In this study, we measured the performance of medical students and interns in a surgery simulator, while their brain activity was monitored by a single-channel EEG. METHODS: A total of 38 medical students and interns were divided into three groups and underwent three experiments examining their behavioral performances. The participants were performing a task while being monitored by the Simbionix LAP MENTOR™. Their brain activity was simultaneously measured using a single-channel EEG with novel signal processing (Aurora by Neurosteer(®)). Each experiment included three trials of a simulator task performed with laparoscopic hands. The time retention between the tasks was different in each experiment, in order to examine changes in performance and cognitive load biomarkers that occurred during the task or as a result of nighttime sleep consolidation. RESULTS: The participants’ behavioral performance improved with trial repetition in all three experiments. In Experiments 1 and 2, delta band and the novel VC9 biomarker (previously shown to correlate with cognitive load) exhibited a significant decrease in activity with trial repetition. Additionally, delta, VC9, and, to some extent, theta activity decreased with better individual performance. DISCUSSION: In correspondence with previous research, EEG markers delta, VC9, and theta (partially) decreased with lower cognitive load and higher performance; the novel biomarker, VC9, showed higher sensitivity to lower cognitive load levels. Together, these measurements may be used for the neuroimaging assessment of cognitive load while performing simulator laparoscopic tasks. This can potentially be expanded to evaluate the efficacy of different medical simulations to provide more efficient training to medical staff and measure cognitive and mental loads in real laparoscopic surgeries.
format Online
Article
Text
id pubmed-8811150
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-88111502022-02-04 Continuous Monitoring of Mental Load During Virtual Simulator Training for Laparoscopic Surgery Reflects Laparoscopic Dexterity: A Comparative Study Using a Novel Wireless Device Maimon, Neta B. Bez, Maxim Drobot, Denis Molcho, Lior Intrator, Nathan Kakiashvilli, Eli Bickel, Amitai Front Neurosci Neuroscience INTRODUCTION: Cognitive Load Theory (CLT) relates to the efficiency with which individuals manipulate the limited capacity of working memory load. Repeated training generally results in individual performance increase and cognitive load decrease, as measured by both behavioral and neuroimaging methods. One of the known biomarkers for cognitive load is frontal theta band, measured by an EEG. Simulation-based training is an effective tool for acquiring practical skills, specifically to train new surgeons in a controlled and hazard-free environment. Measuring the cognitive load of young surgeons undergoing such training can help to determine whether they are ready to take part in a real surgery. In this study, we measured the performance of medical students and interns in a surgery simulator, while their brain activity was monitored by a single-channel EEG. METHODS: A total of 38 medical students and interns were divided into three groups and underwent three experiments examining their behavioral performances. The participants were performing a task while being monitored by the Simbionix LAP MENTOR™. Their brain activity was simultaneously measured using a single-channel EEG with novel signal processing (Aurora by Neurosteer(®)). Each experiment included three trials of a simulator task performed with laparoscopic hands. The time retention between the tasks was different in each experiment, in order to examine changes in performance and cognitive load biomarkers that occurred during the task or as a result of nighttime sleep consolidation. RESULTS: The participants’ behavioral performance improved with trial repetition in all three experiments. In Experiments 1 and 2, delta band and the novel VC9 biomarker (previously shown to correlate with cognitive load) exhibited a significant decrease in activity with trial repetition. Additionally, delta, VC9, and, to some extent, theta activity decreased with better individual performance. DISCUSSION: In correspondence with previous research, EEG markers delta, VC9, and theta (partially) decreased with lower cognitive load and higher performance; the novel biomarker, VC9, showed higher sensitivity to lower cognitive load levels. Together, these measurements may be used for the neuroimaging assessment of cognitive load while performing simulator laparoscopic tasks. This can potentially be expanded to evaluate the efficacy of different medical simulations to provide more efficient training to medical staff and measure cognitive and mental loads in real laparoscopic surgeries. Frontiers Media S.A. 2022-01-20 /pmc/articles/PMC8811150/ /pubmed/35126032 http://dx.doi.org/10.3389/fnins.2021.694010 Text en Copyright © 2022 Maimon, Bez, Drobot, Molcho, Intrator, Kakiashvilli and Bickel. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Maimon, Neta B.
Bez, Maxim
Drobot, Denis
Molcho, Lior
Intrator, Nathan
Kakiashvilli, Eli
Bickel, Amitai
Continuous Monitoring of Mental Load During Virtual Simulator Training for Laparoscopic Surgery Reflects Laparoscopic Dexterity: A Comparative Study Using a Novel Wireless Device
title Continuous Monitoring of Mental Load During Virtual Simulator Training for Laparoscopic Surgery Reflects Laparoscopic Dexterity: A Comparative Study Using a Novel Wireless Device
title_full Continuous Monitoring of Mental Load During Virtual Simulator Training for Laparoscopic Surgery Reflects Laparoscopic Dexterity: A Comparative Study Using a Novel Wireless Device
title_fullStr Continuous Monitoring of Mental Load During Virtual Simulator Training for Laparoscopic Surgery Reflects Laparoscopic Dexterity: A Comparative Study Using a Novel Wireless Device
title_full_unstemmed Continuous Monitoring of Mental Load During Virtual Simulator Training for Laparoscopic Surgery Reflects Laparoscopic Dexterity: A Comparative Study Using a Novel Wireless Device
title_short Continuous Monitoring of Mental Load During Virtual Simulator Training for Laparoscopic Surgery Reflects Laparoscopic Dexterity: A Comparative Study Using a Novel Wireless Device
title_sort continuous monitoring of mental load during virtual simulator training for laparoscopic surgery reflects laparoscopic dexterity: a comparative study using a novel wireless device
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8811150/
https://www.ncbi.nlm.nih.gov/pubmed/35126032
http://dx.doi.org/10.3389/fnins.2021.694010
work_keys_str_mv AT maimonnetab continuousmonitoringofmentalloadduringvirtualsimulatortrainingforlaparoscopicsurgeryreflectslaparoscopicdexterityacomparativestudyusinganovelwirelessdevice
AT bezmaxim continuousmonitoringofmentalloadduringvirtualsimulatortrainingforlaparoscopicsurgeryreflectslaparoscopicdexterityacomparativestudyusinganovelwirelessdevice
AT drobotdenis continuousmonitoringofmentalloadduringvirtualsimulatortrainingforlaparoscopicsurgeryreflectslaparoscopicdexterityacomparativestudyusinganovelwirelessdevice
AT molcholior continuousmonitoringofmentalloadduringvirtualsimulatortrainingforlaparoscopicsurgeryreflectslaparoscopicdexterityacomparativestudyusinganovelwirelessdevice
AT intratornathan continuousmonitoringofmentalloadduringvirtualsimulatortrainingforlaparoscopicsurgeryreflectslaparoscopicdexterityacomparativestudyusinganovelwirelessdevice
AT kakiashvillieli continuousmonitoringofmentalloadduringvirtualsimulatortrainingforlaparoscopicsurgeryreflectslaparoscopicdexterityacomparativestudyusinganovelwirelessdevice
AT bickelamitai continuousmonitoringofmentalloadduringvirtualsimulatortrainingforlaparoscopicsurgeryreflectslaparoscopicdexterityacomparativestudyusinganovelwirelessdevice