Cargando…

Unipolar and bipolar electrogram characteristics of recurrent cases of idiopathic ventricular arrhythmias undergoing repeat catheter ablation

INTRODUCTION: Activation mapping guided catheter ablation (CA) of ventricular arrhythmias (VAs) is limited in some cases when it is only relied on bipolar electrogram (EGM). We hypothesized that activation mapping with use of combined bipolar and unipolar EGM facilitates to identify the focal origin...

Descripción completa

Detalles Bibliográficos
Autores principales: Jena, Anupam, Iqbal, Mohammad, Baek, Yong-Soo, Lee, Kwang- No, Rho, Seung- Young, Shim, Jae Min, Choi, Joing Il, Kim, Young-Hoon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8811281/
https://www.ncbi.nlm.nih.gov/pubmed/34823016
http://dx.doi.org/10.1016/j.ipej.2021.11.005
_version_ 1784644397007110144
author Jena, Anupam
Iqbal, Mohammad
Baek, Yong-Soo
Lee, Kwang- No
Rho, Seung- Young
Shim, Jae Min
Choi, Joing Il
Kim, Young-Hoon
author_facet Jena, Anupam
Iqbal, Mohammad
Baek, Yong-Soo
Lee, Kwang- No
Rho, Seung- Young
Shim, Jae Min
Choi, Joing Il
Kim, Young-Hoon
author_sort Jena, Anupam
collection PubMed
description INTRODUCTION: Activation mapping guided catheter ablation (CA) of ventricular arrhythmias (VAs) is limited in some cases when it is only relied on bipolar electrogram (EGM). We hypothesized that activation mapping with use of combined bipolar and unipolar EGM facilitates to identify the focal origin of VAs and results in reduction of recurrence rate of CA of VAs. METHODS: We analyzed the data of patients undergoing repeat ablations for idiopathic out-flow tract VAs. The EGM of the 1 st and 2 nd ablations were compared for earliest local activation time (LAT), presence of discrete potentials, and polarity reversal, unipolar potential morphology (QS or non-QS), potential amplitude and activation slope. RESULTS: Thirty-seven patients were included. The Local activation time was significantly earlier in the 2nd ablation as compared to the 1st procedure (36.90 msec vs 31.85 msec, P < 0.01). The incidence of discrete potentials and polarity reversal were similar in both procedures (51% vs 57%, P = 0.8 and 62% in both the occasions, respectively). The unipolar voltage was similar in both occasions (6.94 mV vs 7.22 mV in repeat ablations, P = 0.7). The recurrence rate (5.7%) was significantly lower with routine use of combined unipolar and bipolar EGMs, as compared to the use of bipolar EGM alone (16.7%) CONCLUSIONS: Use of both bipolar and unipolar electrograms helps in better delineation of the sites of earliest activation for effective ablation of VAs. Use of unipolar electrograms in addition to bipolar electrograms is associated with lower long term recurrence rate.
format Online
Article
Text
id pubmed-8811281
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-88112812022-02-08 Unipolar and bipolar electrogram characteristics of recurrent cases of idiopathic ventricular arrhythmias undergoing repeat catheter ablation Jena, Anupam Iqbal, Mohammad Baek, Yong-Soo Lee, Kwang- No Rho, Seung- Young Shim, Jae Min Choi, Joing Il Kim, Young-Hoon Indian Pacing Electrophysiol J Original Article INTRODUCTION: Activation mapping guided catheter ablation (CA) of ventricular arrhythmias (VAs) is limited in some cases when it is only relied on bipolar electrogram (EGM). We hypothesized that activation mapping with use of combined bipolar and unipolar EGM facilitates to identify the focal origin of VAs and results in reduction of recurrence rate of CA of VAs. METHODS: We analyzed the data of patients undergoing repeat ablations for idiopathic out-flow tract VAs. The EGM of the 1 st and 2 nd ablations were compared for earliest local activation time (LAT), presence of discrete potentials, and polarity reversal, unipolar potential morphology (QS or non-QS), potential amplitude and activation slope. RESULTS: Thirty-seven patients were included. The Local activation time was significantly earlier in the 2nd ablation as compared to the 1st procedure (36.90 msec vs 31.85 msec, P < 0.01). The incidence of discrete potentials and polarity reversal were similar in both procedures (51% vs 57%, P = 0.8 and 62% in both the occasions, respectively). The unipolar voltage was similar in both occasions (6.94 mV vs 7.22 mV in repeat ablations, P = 0.7). The recurrence rate (5.7%) was significantly lower with routine use of combined unipolar and bipolar EGMs, as compared to the use of bipolar EGM alone (16.7%) CONCLUSIONS: Use of both bipolar and unipolar electrograms helps in better delineation of the sites of earliest activation for effective ablation of VAs. Use of unipolar electrograms in addition to bipolar electrograms is associated with lower long term recurrence rate. Elsevier 2021-11-22 /pmc/articles/PMC8811281/ /pubmed/34823016 http://dx.doi.org/10.1016/j.ipej.2021.11.005 Text en © 2022 Indian Heart Rhythm Society. Published by Elsevier B.V. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Jena, Anupam
Iqbal, Mohammad
Baek, Yong-Soo
Lee, Kwang- No
Rho, Seung- Young
Shim, Jae Min
Choi, Joing Il
Kim, Young-Hoon
Unipolar and bipolar electrogram characteristics of recurrent cases of idiopathic ventricular arrhythmias undergoing repeat catheter ablation
title Unipolar and bipolar electrogram characteristics of recurrent cases of idiopathic ventricular arrhythmias undergoing repeat catheter ablation
title_full Unipolar and bipolar electrogram characteristics of recurrent cases of idiopathic ventricular arrhythmias undergoing repeat catheter ablation
title_fullStr Unipolar and bipolar electrogram characteristics of recurrent cases of idiopathic ventricular arrhythmias undergoing repeat catheter ablation
title_full_unstemmed Unipolar and bipolar electrogram characteristics of recurrent cases of idiopathic ventricular arrhythmias undergoing repeat catheter ablation
title_short Unipolar and bipolar electrogram characteristics of recurrent cases of idiopathic ventricular arrhythmias undergoing repeat catheter ablation
title_sort unipolar and bipolar electrogram characteristics of recurrent cases of idiopathic ventricular arrhythmias undergoing repeat catheter ablation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8811281/
https://www.ncbi.nlm.nih.gov/pubmed/34823016
http://dx.doi.org/10.1016/j.ipej.2021.11.005
work_keys_str_mv AT jenaanupam unipolarandbipolarelectrogramcharacteristicsofrecurrentcasesofidiopathicventriculararrhythmiasundergoingrepeatcatheterablation
AT iqbalmohammad unipolarandbipolarelectrogramcharacteristicsofrecurrentcasesofidiopathicventriculararrhythmiasundergoingrepeatcatheterablation
AT baekyongsoo unipolarandbipolarelectrogramcharacteristicsofrecurrentcasesofidiopathicventriculararrhythmiasundergoingrepeatcatheterablation
AT leekwangno unipolarandbipolarelectrogramcharacteristicsofrecurrentcasesofidiopathicventriculararrhythmiasundergoingrepeatcatheterablation
AT rhoseungyoung unipolarandbipolarelectrogramcharacteristicsofrecurrentcasesofidiopathicventriculararrhythmiasundergoingrepeatcatheterablation
AT shimjaemin unipolarandbipolarelectrogramcharacteristicsofrecurrentcasesofidiopathicventriculararrhythmiasundergoingrepeatcatheterablation
AT choijoingil unipolarandbipolarelectrogramcharacteristicsofrecurrentcasesofidiopathicventriculararrhythmiasundergoingrepeatcatheterablation
AT kimyounghoon unipolarandbipolarelectrogramcharacteristicsofrecurrentcasesofidiopathicventriculararrhythmiasundergoingrepeatcatheterablation