Cargando…

Ocular biometry with swept-source optical coherence tomography-based optical biometer in Japanese patients with EYS-related retinitis pigmentosa: a retrospective study

BACKGROUND: This study aimed to identify the features of ocular biometry in patients with EYS-related retinitis pigmentosa using IOLMaster 700. METHODS: We retrospectively reviewed the medical records of patients with retinitis pigmentosa. Patients with records of the following were included: (1) oc...

Descripción completa

Detalles Bibliográficos
Autores principales: Sakai, Daiki, Yokota, Satoshi, Maeda, Akiko, Hirami, Yasuhiko, Nakamura, Makoto, Kurimoto, Yasuo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8811986/
https://www.ncbi.nlm.nih.gov/pubmed/35109811
http://dx.doi.org/10.1186/s12886-022-02284-3
_version_ 1784644550542753792
author Sakai, Daiki
Yokota, Satoshi
Maeda, Akiko
Hirami, Yasuhiko
Nakamura, Makoto
Kurimoto, Yasuo
author_facet Sakai, Daiki
Yokota, Satoshi
Maeda, Akiko
Hirami, Yasuhiko
Nakamura, Makoto
Kurimoto, Yasuo
author_sort Sakai, Daiki
collection PubMed
description BACKGROUND: This study aimed to identify the features of ocular biometry in patients with EYS-related retinitis pigmentosa using IOLMaster 700. METHODS: We retrospectively reviewed the medical records of patients with retinitis pigmentosa. Patients with records of the following were included: (1) ocular biometry measurements using the IOLMaster 700 and (2) genetic diagnostic tests. Axial length, keratometry, anterior chamber depth, aqueous depth, lens thickness, central corneal thickness (CCT), and corneal diameter (white to white) measurements were extracted. Based on keratometry measurements, (1) standard keratometric astigmatism, (2) posterior corneal astigmatism, and (3) total corneal astigmatism were obtained. Demographics and biometric parameters were compared between patients with EYS-related retinitis pigmentosa and other patients with retinitis pigmentosa. RESULTS: A total of 86 eyes of 44 patients (23 females and 21 males; mean age: 47.7 years) with retinitis pigmentosa were included. Of these, 18 were identified as having EYS variants. CCT was significantly thinner (P < 0.001) and the posterior corneal curvature at the steepest meridian was significantly smaller (P = 0.024) in patients with EYS-related retinitis pigmentosa than in other patients with retinitis pigmentosa. The magnitudes of all corneal astigmatism measurements was higher in patients with EYS-related RP, although these differences were not statistically significant. CONCLUSION: Patients with EYS-related retinitis pigmentosa had unique features in ocular biometry, such as thinner central corneal thickness and smaller posterior corneal curvature radius at the steepest meridian compared with other patients with retinitis pigmentosa. The findings suggest that patients with retinitis pigmentosa have different ocular dimension features among the different causative genes. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12886-022-02284-3.
format Online
Article
Text
id pubmed-8811986
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-88119862022-02-03 Ocular biometry with swept-source optical coherence tomography-based optical biometer in Japanese patients with EYS-related retinitis pigmentosa: a retrospective study Sakai, Daiki Yokota, Satoshi Maeda, Akiko Hirami, Yasuhiko Nakamura, Makoto Kurimoto, Yasuo BMC Ophthalmol Research BACKGROUND: This study aimed to identify the features of ocular biometry in patients with EYS-related retinitis pigmentosa using IOLMaster 700. METHODS: We retrospectively reviewed the medical records of patients with retinitis pigmentosa. Patients with records of the following were included: (1) ocular biometry measurements using the IOLMaster 700 and (2) genetic diagnostic tests. Axial length, keratometry, anterior chamber depth, aqueous depth, lens thickness, central corneal thickness (CCT), and corneal diameter (white to white) measurements were extracted. Based on keratometry measurements, (1) standard keratometric astigmatism, (2) posterior corneal astigmatism, and (3) total corneal astigmatism were obtained. Demographics and biometric parameters were compared between patients with EYS-related retinitis pigmentosa and other patients with retinitis pigmentosa. RESULTS: A total of 86 eyes of 44 patients (23 females and 21 males; mean age: 47.7 years) with retinitis pigmentosa were included. Of these, 18 were identified as having EYS variants. CCT was significantly thinner (P < 0.001) and the posterior corneal curvature at the steepest meridian was significantly smaller (P = 0.024) in patients with EYS-related retinitis pigmentosa than in other patients with retinitis pigmentosa. The magnitudes of all corneal astigmatism measurements was higher in patients with EYS-related RP, although these differences were not statistically significant. CONCLUSION: Patients with EYS-related retinitis pigmentosa had unique features in ocular biometry, such as thinner central corneal thickness and smaller posterior corneal curvature radius at the steepest meridian compared with other patients with retinitis pigmentosa. The findings suggest that patients with retinitis pigmentosa have different ocular dimension features among the different causative genes. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12886-022-02284-3. BioMed Central 2022-02-02 /pmc/articles/PMC8811986/ /pubmed/35109811 http://dx.doi.org/10.1186/s12886-022-02284-3 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Sakai, Daiki
Yokota, Satoshi
Maeda, Akiko
Hirami, Yasuhiko
Nakamura, Makoto
Kurimoto, Yasuo
Ocular biometry with swept-source optical coherence tomography-based optical biometer in Japanese patients with EYS-related retinitis pigmentosa: a retrospective study
title Ocular biometry with swept-source optical coherence tomography-based optical biometer in Japanese patients with EYS-related retinitis pigmentosa: a retrospective study
title_full Ocular biometry with swept-source optical coherence tomography-based optical biometer in Japanese patients with EYS-related retinitis pigmentosa: a retrospective study
title_fullStr Ocular biometry with swept-source optical coherence tomography-based optical biometer in Japanese patients with EYS-related retinitis pigmentosa: a retrospective study
title_full_unstemmed Ocular biometry with swept-source optical coherence tomography-based optical biometer in Japanese patients with EYS-related retinitis pigmentosa: a retrospective study
title_short Ocular biometry with swept-source optical coherence tomography-based optical biometer in Japanese patients with EYS-related retinitis pigmentosa: a retrospective study
title_sort ocular biometry with swept-source optical coherence tomography-based optical biometer in japanese patients with eys-related retinitis pigmentosa: a retrospective study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8811986/
https://www.ncbi.nlm.nih.gov/pubmed/35109811
http://dx.doi.org/10.1186/s12886-022-02284-3
work_keys_str_mv AT sakaidaiki ocularbiometrywithsweptsourceopticalcoherencetomographybasedopticalbiometerinjapanesepatientswitheysrelatedretinitispigmentosaaretrospectivestudy
AT yokotasatoshi ocularbiometrywithsweptsourceopticalcoherencetomographybasedopticalbiometerinjapanesepatientswitheysrelatedretinitispigmentosaaretrospectivestudy
AT maedaakiko ocularbiometrywithsweptsourceopticalcoherencetomographybasedopticalbiometerinjapanesepatientswitheysrelatedretinitispigmentosaaretrospectivestudy
AT hiramiyasuhiko ocularbiometrywithsweptsourceopticalcoherencetomographybasedopticalbiometerinjapanesepatientswitheysrelatedretinitispigmentosaaretrospectivestudy
AT nakamuramakoto ocularbiometrywithsweptsourceopticalcoherencetomographybasedopticalbiometerinjapanesepatientswitheysrelatedretinitispigmentosaaretrospectivestudy
AT kurimotoyasuo ocularbiometrywithsweptsourceopticalcoherencetomographybasedopticalbiometerinjapanesepatientswitheysrelatedretinitispigmentosaaretrospectivestudy