Cargando…

Real-Time Sensing of Output Polymer Flow Temperature and Volumetric Flowrate in Fused Filament Fabrication Process

In this paper we addressed key challenges in engineering an instrumentation system for sensing and signal processing for real-time estimation of two main process variables in the Fused-Filament-Fabrication process: (i) temperature of the polymer melt exiting the nozzle using a thermocouple; and (ii)...

Descripción completa

Detalles Bibliográficos
Autores principales: Badarinath, Rakshith, Prabhu, Vittaldas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8812280/
https://www.ncbi.nlm.nih.gov/pubmed/35057332
http://dx.doi.org/10.3390/ma15020618
_version_ 1784644614956777472
author Badarinath, Rakshith
Prabhu, Vittaldas
author_facet Badarinath, Rakshith
Prabhu, Vittaldas
author_sort Badarinath, Rakshith
collection PubMed
description In this paper we addressed key challenges in engineering an instrumentation system for sensing and signal processing for real-time estimation of two main process variables in the Fused-Filament-Fabrication process: (i) temperature of the polymer melt exiting the nozzle using a thermocouple; and (ii) polymer flowrate using extrusion width measurements in real-time, in-situ, using a microscope camera. We used a design of experiments approach to develop response surface models for two materials that enable accurate estimation of the polymer exit temperature as a function of polymer flowrate and liquefier temperature with a fit of [Formula: see text]. The live video stream of the deposition process was used to compute the flowrate based on a road geometry model. Specifically, a robust extrusion width recognizer [Formula: see text] algorithm was developed to identify edges of the deposited road and for real-time computation of extrusion width, which was found to be robust to filament colors and materials. The extrusion width measurement was found to be within 0.08 mm of caliper measurements with an [Formula: see text] value of 99.91% and was found to closely track the requested flowrate from the slicer. This opens new avenues for advancing the engineering science for process monitoring and control of FFF.
format Online
Article
Text
id pubmed-8812280
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-88122802022-02-04 Real-Time Sensing of Output Polymer Flow Temperature and Volumetric Flowrate in Fused Filament Fabrication Process Badarinath, Rakshith Prabhu, Vittaldas Materials (Basel) Article In this paper we addressed key challenges in engineering an instrumentation system for sensing and signal processing for real-time estimation of two main process variables in the Fused-Filament-Fabrication process: (i) temperature of the polymer melt exiting the nozzle using a thermocouple; and (ii) polymer flowrate using extrusion width measurements in real-time, in-situ, using a microscope camera. We used a design of experiments approach to develop response surface models for two materials that enable accurate estimation of the polymer exit temperature as a function of polymer flowrate and liquefier temperature with a fit of [Formula: see text]. The live video stream of the deposition process was used to compute the flowrate based on a road geometry model. Specifically, a robust extrusion width recognizer [Formula: see text] algorithm was developed to identify edges of the deposited road and for real-time computation of extrusion width, which was found to be robust to filament colors and materials. The extrusion width measurement was found to be within 0.08 mm of caliper measurements with an [Formula: see text] value of 99.91% and was found to closely track the requested flowrate from the slicer. This opens new avenues for advancing the engineering science for process monitoring and control of FFF. MDPI 2022-01-14 /pmc/articles/PMC8812280/ /pubmed/35057332 http://dx.doi.org/10.3390/ma15020618 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Badarinath, Rakshith
Prabhu, Vittaldas
Real-Time Sensing of Output Polymer Flow Temperature and Volumetric Flowrate in Fused Filament Fabrication Process
title Real-Time Sensing of Output Polymer Flow Temperature and Volumetric Flowrate in Fused Filament Fabrication Process
title_full Real-Time Sensing of Output Polymer Flow Temperature and Volumetric Flowrate in Fused Filament Fabrication Process
title_fullStr Real-Time Sensing of Output Polymer Flow Temperature and Volumetric Flowrate in Fused Filament Fabrication Process
title_full_unstemmed Real-Time Sensing of Output Polymer Flow Temperature and Volumetric Flowrate in Fused Filament Fabrication Process
title_short Real-Time Sensing of Output Polymer Flow Temperature and Volumetric Flowrate in Fused Filament Fabrication Process
title_sort real-time sensing of output polymer flow temperature and volumetric flowrate in fused filament fabrication process
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8812280/
https://www.ncbi.nlm.nih.gov/pubmed/35057332
http://dx.doi.org/10.3390/ma15020618
work_keys_str_mv AT badarinathrakshith realtimesensingofoutputpolymerflowtemperatureandvolumetricflowrateinfusedfilamentfabricationprocess
AT prabhuvittaldas realtimesensingofoutputpolymerflowtemperatureandvolumetricflowrateinfusedfilamentfabricationprocess