Cargando…
Comparing Cardiac Output Measurements Using a Wearable, Wireless, Noninvasive Photoplethysmography-Based Device to Pulse Contour Cardiac Output in the General ICU: A Brief Report
OBJECTIVES: Cardiac output (CO) measurements in the ICU are usually based on invasive techniques, which are technically complex and associated with clinical complications. This study aimed to compare CO measurements obtained from a noninvasive photoplethysmography-based device to a pulse contour car...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8812679/ https://www.ncbi.nlm.nih.gov/pubmed/35128457 http://dx.doi.org/10.1097/CCE.0000000000000624 |
_version_ | 1784644705460420608 |
---|---|
author | Dvir, Ayana Goldstein, Nir Rapoport, Avigal Balmor, Ronen Gingy Nachman, Dean Merin, Roei Fons, Meir Ben Ishay, Arik Eisenkraft, Arik |
author_facet | Dvir, Ayana Goldstein, Nir Rapoport, Avigal Balmor, Ronen Gingy Nachman, Dean Merin, Roei Fons, Meir Ben Ishay, Arik Eisenkraft, Arik |
author_sort | Dvir, Ayana |
collection | PubMed |
description | OBJECTIVES: Cardiac output (CO) measurements in the ICU are usually based on invasive techniques, which are technically complex and associated with clinical complications. This study aimed to compare CO measurements obtained from a noninvasive photoplethysmography-based device to a pulse contour cardiac output device in ICU patients. DESIGN: Observational, prospective, comparative clinical trial. SETTING: Single-center general ICU. PATIENTS: Patients admitted to the general ICU monitored using a pulse contour cardiac output device as per the decision of the attending physician. INTERVENTIONS: Parallel monitoring of CO using a photoplethysmography-based chest patch device and pulse contour cardiac output while the medical team was blinded to the values obtained by the noninvasive device. MEASUREMENTS AND MAIN RESULTS: Seven patients (69 measurements) were included in the final analysis. Mean CO were 7.3 ± 2.0 L/m and 7.0 ± 1.5 L/m for thermodilution and photoplethysmography, respectively. Bland-Altman showed that the photoplethysmography has a bias of 0.3 L/m with –1.6 and 2.2 L/m 95% limit of agreement (LOA) and a bias of 2.4% with 95% LOA between –25.7% and 30.5% when calculating the percentage of difference from thermodilution. The values obtained by thermodilution and photoplethysmography were highly correlated (r = 0.906). CONCLUSIONS: The tested chest patch device offers a high accuracy for CO compared to data obtained by the pulse contour cardiac output and the thermodilution method in ICU patients. Such devices could offer advanced monitoring capabilities in a variety of clinical settings, without the complications of invasive devices. |
format | Online Article Text |
id | pubmed-8812679 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-88126792022-02-04 Comparing Cardiac Output Measurements Using a Wearable, Wireless, Noninvasive Photoplethysmography-Based Device to Pulse Contour Cardiac Output in the General ICU: A Brief Report Dvir, Ayana Goldstein, Nir Rapoport, Avigal Balmor, Ronen Gingy Nachman, Dean Merin, Roei Fons, Meir Ben Ishay, Arik Eisenkraft, Arik Crit Care Explor Brief Report OBJECTIVES: Cardiac output (CO) measurements in the ICU are usually based on invasive techniques, which are technically complex and associated with clinical complications. This study aimed to compare CO measurements obtained from a noninvasive photoplethysmography-based device to a pulse contour cardiac output device in ICU patients. DESIGN: Observational, prospective, comparative clinical trial. SETTING: Single-center general ICU. PATIENTS: Patients admitted to the general ICU monitored using a pulse contour cardiac output device as per the decision of the attending physician. INTERVENTIONS: Parallel monitoring of CO using a photoplethysmography-based chest patch device and pulse contour cardiac output while the medical team was blinded to the values obtained by the noninvasive device. MEASUREMENTS AND MAIN RESULTS: Seven patients (69 measurements) were included in the final analysis. Mean CO were 7.3 ± 2.0 L/m and 7.0 ± 1.5 L/m for thermodilution and photoplethysmography, respectively. Bland-Altman showed that the photoplethysmography has a bias of 0.3 L/m with –1.6 and 2.2 L/m 95% limit of agreement (LOA) and a bias of 2.4% with 95% LOA between –25.7% and 30.5% when calculating the percentage of difference from thermodilution. The values obtained by thermodilution and photoplethysmography were highly correlated (r = 0.906). CONCLUSIONS: The tested chest patch device offers a high accuracy for CO compared to data obtained by the pulse contour cardiac output and the thermodilution method in ICU patients. Such devices could offer advanced monitoring capabilities in a variety of clinical settings, without the complications of invasive devices. Lippincott Williams & Wilkins 2022-02-01 /pmc/articles/PMC8812679/ /pubmed/35128457 http://dx.doi.org/10.1097/CCE.0000000000000624 Text en Copyright © 2022 The Authors. Published by Wolters Kluwer Health, Inc. on behalf of the Society of Critical Care Medicine. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (https://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. |
spellingShingle | Brief Report Dvir, Ayana Goldstein, Nir Rapoport, Avigal Balmor, Ronen Gingy Nachman, Dean Merin, Roei Fons, Meir Ben Ishay, Arik Eisenkraft, Arik Comparing Cardiac Output Measurements Using a Wearable, Wireless, Noninvasive Photoplethysmography-Based Device to Pulse Contour Cardiac Output in the General ICU: A Brief Report |
title | Comparing Cardiac Output Measurements Using a Wearable, Wireless, Noninvasive Photoplethysmography-Based Device to Pulse Contour Cardiac Output in the General ICU: A Brief Report |
title_full | Comparing Cardiac Output Measurements Using a Wearable, Wireless, Noninvasive Photoplethysmography-Based Device to Pulse Contour Cardiac Output in the General ICU: A Brief Report |
title_fullStr | Comparing Cardiac Output Measurements Using a Wearable, Wireless, Noninvasive Photoplethysmography-Based Device to Pulse Contour Cardiac Output in the General ICU: A Brief Report |
title_full_unstemmed | Comparing Cardiac Output Measurements Using a Wearable, Wireless, Noninvasive Photoplethysmography-Based Device to Pulse Contour Cardiac Output in the General ICU: A Brief Report |
title_short | Comparing Cardiac Output Measurements Using a Wearable, Wireless, Noninvasive Photoplethysmography-Based Device to Pulse Contour Cardiac Output in the General ICU: A Brief Report |
title_sort | comparing cardiac output measurements using a wearable, wireless, noninvasive photoplethysmography-based device to pulse contour cardiac output in the general icu: a brief report |
topic | Brief Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8812679/ https://www.ncbi.nlm.nih.gov/pubmed/35128457 http://dx.doi.org/10.1097/CCE.0000000000000624 |
work_keys_str_mv | AT dvirayana comparingcardiacoutputmeasurementsusingawearablewirelessnoninvasivephotoplethysmographybaseddevicetopulsecontourcardiacoutputinthegeneralicuabriefreport AT goldsteinnir comparingcardiacoutputmeasurementsusingawearablewirelessnoninvasivephotoplethysmographybaseddevicetopulsecontourcardiacoutputinthegeneralicuabriefreport AT rapoportavigal comparingcardiacoutputmeasurementsusingawearablewirelessnoninvasivephotoplethysmographybaseddevicetopulsecontourcardiacoutputinthegeneralicuabriefreport AT balmorronengingy comparingcardiacoutputmeasurementsusingawearablewirelessnoninvasivephotoplethysmographybaseddevicetopulsecontourcardiacoutputinthegeneralicuabriefreport AT nachmandean comparingcardiacoutputmeasurementsusingawearablewirelessnoninvasivephotoplethysmographybaseddevicetopulsecontourcardiacoutputinthegeneralicuabriefreport AT merinroei comparingcardiacoutputmeasurementsusingawearablewirelessnoninvasivephotoplethysmographybaseddevicetopulsecontourcardiacoutputinthegeneralicuabriefreport AT fonsmeir comparingcardiacoutputmeasurementsusingawearablewirelessnoninvasivephotoplethysmographybaseddevicetopulsecontourcardiacoutputinthegeneralicuabriefreport AT benishayarik comparingcardiacoutputmeasurementsusingawearablewirelessnoninvasivephotoplethysmographybaseddevicetopulsecontourcardiacoutputinthegeneralicuabriefreport AT eisenkraftarik comparingcardiacoutputmeasurementsusingawearablewirelessnoninvasivephotoplethysmographybaseddevicetopulsecontourcardiacoutputinthegeneralicuabriefreport |