Comparing Cardiac Output Measurements Using a Wearable, Wireless, Noninvasive Photoplethysmography-Based Device to Pulse Contour Cardiac Output in the General ICU: A Brief Report

OBJECTIVES: Cardiac output (CO) measurements in the ICU are usually based on invasive techniques, which are technically complex and associated with clinical complications. This study aimed to compare CO measurements obtained from a noninvasive photoplethysmography-based device to a pulse contour car...

Descripción completa

Detalles Bibliográficos
Autores principales: Dvir, Ayana, Goldstein, Nir, Rapoport, Avigal, Balmor, Ronen Gingy, Nachman, Dean, Merin, Roei, Fons, Meir, Ben Ishay, Arik, Eisenkraft, Arik
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8812679/
https://www.ncbi.nlm.nih.gov/pubmed/35128457
http://dx.doi.org/10.1097/CCE.0000000000000624
_version_ 1784644705460420608
author Dvir, Ayana
Goldstein, Nir
Rapoport, Avigal
Balmor, Ronen Gingy
Nachman, Dean
Merin, Roei
Fons, Meir
Ben Ishay, Arik
Eisenkraft, Arik
author_facet Dvir, Ayana
Goldstein, Nir
Rapoport, Avigal
Balmor, Ronen Gingy
Nachman, Dean
Merin, Roei
Fons, Meir
Ben Ishay, Arik
Eisenkraft, Arik
author_sort Dvir, Ayana
collection PubMed
description OBJECTIVES: Cardiac output (CO) measurements in the ICU are usually based on invasive techniques, which are technically complex and associated with clinical complications. This study aimed to compare CO measurements obtained from a noninvasive photoplethysmography-based device to a pulse contour cardiac output device in ICU patients. DESIGN: Observational, prospective, comparative clinical trial. SETTING: Single-center general ICU. PATIENTS: Patients admitted to the general ICU monitored using a pulse contour cardiac output device as per the decision of the attending physician. INTERVENTIONS: Parallel monitoring of CO using a photoplethysmography-based chest patch device and pulse contour cardiac output while the medical team was blinded to the values obtained by the noninvasive device. MEASUREMENTS AND MAIN RESULTS: Seven patients (69 measurements) were included in the final analysis. Mean CO were 7.3 ± 2.0 L/m and 7.0 ± 1.5 L/m for thermodilution and photoplethysmography, respectively. Bland-Altman showed that the photoplethysmography has a bias of 0.3 L/m with –1.6 and 2.2 L/m 95% limit of agreement (LOA) and a bias of 2.4% with 95% LOA between –25.7% and 30.5% when calculating the percentage of difference from thermodilution. The values obtained by thermodilution and photoplethysmography were highly correlated (r = 0.906). CONCLUSIONS: The tested chest patch device offers a high accuracy for CO compared to data obtained by the pulse contour cardiac output and the thermodilution method in ICU patients. Such devices could offer advanced monitoring capabilities in a variety of clinical settings, without the complications of invasive devices.
format Online
Article
Text
id pubmed-8812679
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-88126792022-02-04 Comparing Cardiac Output Measurements Using a Wearable, Wireless, Noninvasive Photoplethysmography-Based Device to Pulse Contour Cardiac Output in the General ICU: A Brief Report Dvir, Ayana Goldstein, Nir Rapoport, Avigal Balmor, Ronen Gingy Nachman, Dean Merin, Roei Fons, Meir Ben Ishay, Arik Eisenkraft, Arik Crit Care Explor Brief Report OBJECTIVES: Cardiac output (CO) measurements in the ICU are usually based on invasive techniques, which are technically complex and associated with clinical complications. This study aimed to compare CO measurements obtained from a noninvasive photoplethysmography-based device to a pulse contour cardiac output device in ICU patients. DESIGN: Observational, prospective, comparative clinical trial. SETTING: Single-center general ICU. PATIENTS: Patients admitted to the general ICU monitored using a pulse contour cardiac output device as per the decision of the attending physician. INTERVENTIONS: Parallel monitoring of CO using a photoplethysmography-based chest patch device and pulse contour cardiac output while the medical team was blinded to the values obtained by the noninvasive device. MEASUREMENTS AND MAIN RESULTS: Seven patients (69 measurements) were included in the final analysis. Mean CO were 7.3 ± 2.0 L/m and 7.0 ± 1.5 L/m for thermodilution and photoplethysmography, respectively. Bland-Altman showed that the photoplethysmography has a bias of 0.3 L/m with –1.6 and 2.2 L/m 95% limit of agreement (LOA) and a bias of 2.4% with 95% LOA between –25.7% and 30.5% when calculating the percentage of difference from thermodilution. The values obtained by thermodilution and photoplethysmography were highly correlated (r = 0.906). CONCLUSIONS: The tested chest patch device offers a high accuracy for CO compared to data obtained by the pulse contour cardiac output and the thermodilution method in ICU patients. Such devices could offer advanced monitoring capabilities in a variety of clinical settings, without the complications of invasive devices. Lippincott Williams & Wilkins 2022-02-01 /pmc/articles/PMC8812679/ /pubmed/35128457 http://dx.doi.org/10.1097/CCE.0000000000000624 Text en Copyright © 2022 The Authors. Published by Wolters Kluwer Health, Inc. on behalf of the Society of Critical Care Medicine. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (https://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Brief Report
Dvir, Ayana
Goldstein, Nir
Rapoport, Avigal
Balmor, Ronen Gingy
Nachman, Dean
Merin, Roei
Fons, Meir
Ben Ishay, Arik
Eisenkraft, Arik
Comparing Cardiac Output Measurements Using a Wearable, Wireless, Noninvasive Photoplethysmography-Based Device to Pulse Contour Cardiac Output in the General ICU: A Brief Report
title Comparing Cardiac Output Measurements Using a Wearable, Wireless, Noninvasive Photoplethysmography-Based Device to Pulse Contour Cardiac Output in the General ICU: A Brief Report
title_full Comparing Cardiac Output Measurements Using a Wearable, Wireless, Noninvasive Photoplethysmography-Based Device to Pulse Contour Cardiac Output in the General ICU: A Brief Report
title_fullStr Comparing Cardiac Output Measurements Using a Wearable, Wireless, Noninvasive Photoplethysmography-Based Device to Pulse Contour Cardiac Output in the General ICU: A Brief Report
title_full_unstemmed Comparing Cardiac Output Measurements Using a Wearable, Wireless, Noninvasive Photoplethysmography-Based Device to Pulse Contour Cardiac Output in the General ICU: A Brief Report
title_short Comparing Cardiac Output Measurements Using a Wearable, Wireless, Noninvasive Photoplethysmography-Based Device to Pulse Contour Cardiac Output in the General ICU: A Brief Report
title_sort comparing cardiac output measurements using a wearable, wireless, noninvasive photoplethysmography-based device to pulse contour cardiac output in the general icu: a brief report
topic Brief Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8812679/
https://www.ncbi.nlm.nih.gov/pubmed/35128457
http://dx.doi.org/10.1097/CCE.0000000000000624
work_keys_str_mv AT dvirayana comparingcardiacoutputmeasurementsusingawearablewirelessnoninvasivephotoplethysmographybaseddevicetopulsecontourcardiacoutputinthegeneralicuabriefreport
AT goldsteinnir comparingcardiacoutputmeasurementsusingawearablewirelessnoninvasivephotoplethysmographybaseddevicetopulsecontourcardiacoutputinthegeneralicuabriefreport
AT rapoportavigal comparingcardiacoutputmeasurementsusingawearablewirelessnoninvasivephotoplethysmographybaseddevicetopulsecontourcardiacoutputinthegeneralicuabriefreport
AT balmorronengingy comparingcardiacoutputmeasurementsusingawearablewirelessnoninvasivephotoplethysmographybaseddevicetopulsecontourcardiacoutputinthegeneralicuabriefreport
AT nachmandean comparingcardiacoutputmeasurementsusingawearablewirelessnoninvasivephotoplethysmographybaseddevicetopulsecontourcardiacoutputinthegeneralicuabriefreport
AT merinroei comparingcardiacoutputmeasurementsusingawearablewirelessnoninvasivephotoplethysmographybaseddevicetopulsecontourcardiacoutputinthegeneralicuabriefreport
AT fonsmeir comparingcardiacoutputmeasurementsusingawearablewirelessnoninvasivephotoplethysmographybaseddevicetopulsecontourcardiacoutputinthegeneralicuabriefreport
AT benishayarik comparingcardiacoutputmeasurementsusingawearablewirelessnoninvasivephotoplethysmographybaseddevicetopulsecontourcardiacoutputinthegeneralicuabriefreport
AT eisenkraftarik comparingcardiacoutputmeasurementsusingawearablewirelessnoninvasivephotoplethysmographybaseddevicetopulsecontourcardiacoutputinthegeneralicuabriefreport