Cargando…
Detecting hip osteoarthritis on clinical CT: a deep learning application based on 2-D summation images derived from CT
SUMMARY: We developed and compared deep learning models to detect hip osteoarthritis on clinical CT. The CT-based summation images, CT-AP, that resemble X-ray radiographs can detect radiographic hip osteoarthritis and in the absence of large training data, a reliable deep learning model can be optim...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer London
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8813821/ https://www.ncbi.nlm.nih.gov/pubmed/34476540 http://dx.doi.org/10.1007/s00198-021-06130-y |
Sumario: | SUMMARY: We developed and compared deep learning models to detect hip osteoarthritis on clinical CT. The CT-based summation images, CT-AP, that resemble X-ray radiographs can detect radiographic hip osteoarthritis and in the absence of large training data, a reliable deep learning model can be optimized by combining CT-AP and X-ray images. INTRODUCTION: In this study, we aimed to investigate the applicability of deep learning (DL) to assess radiographic hip osteoarthritis (rHOA) on computed tomography (CT). METHODS: The study data consisted of 94 abdominopelvic clinical CTs and 5659 hip X-ray images collected from Cohort Hip and Cohort Knee (CHECK). The CT slices were sequentially summed to create radiograph-like 2-D images named CT-AP. X-ray and CT-AP images were classified as rHOA if they had osteoarthritic changes corresponding to Kellgren-Lawrence grade 2 or higher. The study data was split into 55% training, 30% validation, and 15% test sets. A pretrained ResNet18 was optimized for a classification task of rHOA vs. no-rHOA. Five models were trained using (1) X-rays, (2) downsampled X-rays, (3) combination of CT-AP and X-ray images, (4) combination of CT-AP and downsampled X-ray images, and (5) CT-AP images. RESULTS: Amongst the five models, Model-3 and Model-5 performed best in detecting rHOA from the CT-AP images. Model-3 detected rHOA on the test set of CT-AP images with a balanced accuracy of 82.2% and was able to discriminate rHOA from no-rHOA with an area under the receiver operating characteristic curve (ROC AUC) of 0.93 [0.75–0.99]. Model-5 detected rHOA on the test set at a balanced accuracy of 82.2% and classified rHOA from no-rHOA with an ROC AUC of 0.89 [0.67–0.97]. CONCLUSION: CT-based summation images that resemble radiographs can be used to detect rHOA. In addition, in the absence of large training data, a reliable DL model can be optimized by combining CT-AP and X-ray images. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00198-021-06130-y. |
---|