Cargando…

Influence of Ocular Residual Astigmatism and Target-Induced Astigmatism on the Efficacy of the Implantation of a Toric Implantable Collamer Lens With Central Hole for Myopic Astigmatism Correction

PURPOSE: To investigate the effects of ocular residual astigmatism (ORA) and target-induced astigmatism (TIA) on the efficacy of toric implantable collamer lens (TICL) with central hole for myopic astigmatism correction. METHODS: Retrospective case series. One hundred and eighteen eyes implanted wit...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhao, Jing, Zhao, Jiao, Yang, Wen, Sun, Ling, Qian, Yishan, Wang, Xiaoying, Zhou, Xingtao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8813979/
https://www.ncbi.nlm.nih.gov/pubmed/35127737
http://dx.doi.org/10.3389/fmed.2021.737358
_version_ 1784644975554723840
author Zhao, Jing
Zhao, Jiao
Yang, Wen
Sun, Ling
Qian, Yishan
Wang, Xiaoying
Zhou, Xingtao
author_facet Zhao, Jing
Zhao, Jiao
Yang, Wen
Sun, Ling
Qian, Yishan
Wang, Xiaoying
Zhou, Xingtao
author_sort Zhao, Jing
collection PubMed
description PURPOSE: To investigate the effects of ocular residual astigmatism (ORA) and target-induced astigmatism (TIA) on the efficacy of toric implantable collamer lens (TICL) with central hole for myopic astigmatism correction. METHODS: Retrospective case series. One hundred and eighteen eyes implanted with a TICL (V4c) from 118 patients were included. Subjective refraction and corneal topography were examined preoperatively, at 1 and 12 months postoperatively. The eyes were divided into the low-ORA ( ≤ 0.5 D) and high-ORA (>0.5 D) groups based on vector analysis, and into the low-TIA (≥0.75D and <2 D) and the high-TIA (≥2 D and ≤ 4 D) groups according to preoperative refractive astigmatism. Correction index (CI) and index of success (IOS) were compared between different groups. RESULTS: All surgeries were uneventful, and no complications occurred during follow-up. At 1 and 12 months postoperatively, no significant differences were found in CI or IOS values between the high and low ORA groups, while significantly higher CI and lower IOS were detected in the high-TIA group than in the low-TIA group (P < 0.05). No significant difference was found in CI between 1 and 12 months postoperatively in either group (P > 0.05). However, significantly lower IOS was found at 12 months compared with 1 month postoperatively for each group (P < 0.05). CONCLUSIONS: Toric implantable collamer lens (TICL) implantation is effective in correcting myopic astigmatism and is more effective in eyes with high TIA, while ORA has a minor effect.
format Online
Article
Text
id pubmed-8813979
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-88139792022-02-05 Influence of Ocular Residual Astigmatism and Target-Induced Astigmatism on the Efficacy of the Implantation of a Toric Implantable Collamer Lens With Central Hole for Myopic Astigmatism Correction Zhao, Jing Zhao, Jiao Yang, Wen Sun, Ling Qian, Yishan Wang, Xiaoying Zhou, Xingtao Front Med (Lausanne) Medicine PURPOSE: To investigate the effects of ocular residual astigmatism (ORA) and target-induced astigmatism (TIA) on the efficacy of toric implantable collamer lens (TICL) with central hole for myopic astigmatism correction. METHODS: Retrospective case series. One hundred and eighteen eyes implanted with a TICL (V4c) from 118 patients were included. Subjective refraction and corneal topography were examined preoperatively, at 1 and 12 months postoperatively. The eyes were divided into the low-ORA ( ≤ 0.5 D) and high-ORA (>0.5 D) groups based on vector analysis, and into the low-TIA (≥0.75D and <2 D) and the high-TIA (≥2 D and ≤ 4 D) groups according to preoperative refractive astigmatism. Correction index (CI) and index of success (IOS) were compared between different groups. RESULTS: All surgeries were uneventful, and no complications occurred during follow-up. At 1 and 12 months postoperatively, no significant differences were found in CI or IOS values between the high and low ORA groups, while significantly higher CI and lower IOS were detected in the high-TIA group than in the low-TIA group (P < 0.05). No significant difference was found in CI between 1 and 12 months postoperatively in either group (P > 0.05). However, significantly lower IOS was found at 12 months compared with 1 month postoperatively for each group (P < 0.05). CONCLUSIONS: Toric implantable collamer lens (TICL) implantation is effective in correcting myopic astigmatism and is more effective in eyes with high TIA, while ORA has a minor effect. Frontiers Media S.A. 2022-01-21 /pmc/articles/PMC8813979/ /pubmed/35127737 http://dx.doi.org/10.3389/fmed.2021.737358 Text en Copyright © 2022 Zhao, Zhao, Yang, Sun, Qian, Wang and Zhou. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Medicine
Zhao, Jing
Zhao, Jiao
Yang, Wen
Sun, Ling
Qian, Yishan
Wang, Xiaoying
Zhou, Xingtao
Influence of Ocular Residual Astigmatism and Target-Induced Astigmatism on the Efficacy of the Implantation of a Toric Implantable Collamer Lens With Central Hole for Myopic Astigmatism Correction
title Influence of Ocular Residual Astigmatism and Target-Induced Astigmatism on the Efficacy of the Implantation of a Toric Implantable Collamer Lens With Central Hole for Myopic Astigmatism Correction
title_full Influence of Ocular Residual Astigmatism and Target-Induced Astigmatism on the Efficacy of the Implantation of a Toric Implantable Collamer Lens With Central Hole for Myopic Astigmatism Correction
title_fullStr Influence of Ocular Residual Astigmatism and Target-Induced Astigmatism on the Efficacy of the Implantation of a Toric Implantable Collamer Lens With Central Hole for Myopic Astigmatism Correction
title_full_unstemmed Influence of Ocular Residual Astigmatism and Target-Induced Astigmatism on the Efficacy of the Implantation of a Toric Implantable Collamer Lens With Central Hole for Myopic Astigmatism Correction
title_short Influence of Ocular Residual Astigmatism and Target-Induced Astigmatism on the Efficacy of the Implantation of a Toric Implantable Collamer Lens With Central Hole for Myopic Astigmatism Correction
title_sort influence of ocular residual astigmatism and target-induced astigmatism on the efficacy of the implantation of a toric implantable collamer lens with central hole for myopic astigmatism correction
topic Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8813979/
https://www.ncbi.nlm.nih.gov/pubmed/35127737
http://dx.doi.org/10.3389/fmed.2021.737358
work_keys_str_mv AT zhaojing influenceofocularresidualastigmatismandtargetinducedastigmatismontheefficacyoftheimplantationofatoricimplantablecollamerlenswithcentralholeformyopicastigmatismcorrection
AT zhaojiao influenceofocularresidualastigmatismandtargetinducedastigmatismontheefficacyoftheimplantationofatoricimplantablecollamerlenswithcentralholeformyopicastigmatismcorrection
AT yangwen influenceofocularresidualastigmatismandtargetinducedastigmatismontheefficacyoftheimplantationofatoricimplantablecollamerlenswithcentralholeformyopicastigmatismcorrection
AT sunling influenceofocularresidualastigmatismandtargetinducedastigmatismontheefficacyoftheimplantationofatoricimplantablecollamerlenswithcentralholeformyopicastigmatismcorrection
AT qianyishan influenceofocularresidualastigmatismandtargetinducedastigmatismontheefficacyoftheimplantationofatoricimplantablecollamerlenswithcentralholeformyopicastigmatismcorrection
AT wangxiaoying influenceofocularresidualastigmatismandtargetinducedastigmatismontheefficacyoftheimplantationofatoricimplantablecollamerlenswithcentralholeformyopicastigmatismcorrection
AT zhouxingtao influenceofocularresidualastigmatismandtargetinducedastigmatismontheefficacyoftheimplantationofatoricimplantablecollamerlenswithcentralholeformyopicastigmatismcorrection