Cargando…
Influence of Ocular Residual Astigmatism and Target-Induced Astigmatism on the Efficacy of the Implantation of a Toric Implantable Collamer Lens With Central Hole for Myopic Astigmatism Correction
PURPOSE: To investigate the effects of ocular residual astigmatism (ORA) and target-induced astigmatism (TIA) on the efficacy of toric implantable collamer lens (TICL) with central hole for myopic astigmatism correction. METHODS: Retrospective case series. One hundred and eighteen eyes implanted wit...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8813979/ https://www.ncbi.nlm.nih.gov/pubmed/35127737 http://dx.doi.org/10.3389/fmed.2021.737358 |
_version_ | 1784644975554723840 |
---|---|
author | Zhao, Jing Zhao, Jiao Yang, Wen Sun, Ling Qian, Yishan Wang, Xiaoying Zhou, Xingtao |
author_facet | Zhao, Jing Zhao, Jiao Yang, Wen Sun, Ling Qian, Yishan Wang, Xiaoying Zhou, Xingtao |
author_sort | Zhao, Jing |
collection | PubMed |
description | PURPOSE: To investigate the effects of ocular residual astigmatism (ORA) and target-induced astigmatism (TIA) on the efficacy of toric implantable collamer lens (TICL) with central hole for myopic astigmatism correction. METHODS: Retrospective case series. One hundred and eighteen eyes implanted with a TICL (V4c) from 118 patients were included. Subjective refraction and corneal topography were examined preoperatively, at 1 and 12 months postoperatively. The eyes were divided into the low-ORA ( ≤ 0.5 D) and high-ORA (>0.5 D) groups based on vector analysis, and into the low-TIA (≥0.75D and <2 D) and the high-TIA (≥2 D and ≤ 4 D) groups according to preoperative refractive astigmatism. Correction index (CI) and index of success (IOS) were compared between different groups. RESULTS: All surgeries were uneventful, and no complications occurred during follow-up. At 1 and 12 months postoperatively, no significant differences were found in CI or IOS values between the high and low ORA groups, while significantly higher CI and lower IOS were detected in the high-TIA group than in the low-TIA group (P < 0.05). No significant difference was found in CI between 1 and 12 months postoperatively in either group (P > 0.05). However, significantly lower IOS was found at 12 months compared with 1 month postoperatively for each group (P < 0.05). CONCLUSIONS: Toric implantable collamer lens (TICL) implantation is effective in correcting myopic astigmatism and is more effective in eyes with high TIA, while ORA has a minor effect. |
format | Online Article Text |
id | pubmed-8813979 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-88139792022-02-05 Influence of Ocular Residual Astigmatism and Target-Induced Astigmatism on the Efficacy of the Implantation of a Toric Implantable Collamer Lens With Central Hole for Myopic Astigmatism Correction Zhao, Jing Zhao, Jiao Yang, Wen Sun, Ling Qian, Yishan Wang, Xiaoying Zhou, Xingtao Front Med (Lausanne) Medicine PURPOSE: To investigate the effects of ocular residual astigmatism (ORA) and target-induced astigmatism (TIA) on the efficacy of toric implantable collamer lens (TICL) with central hole for myopic astigmatism correction. METHODS: Retrospective case series. One hundred and eighteen eyes implanted with a TICL (V4c) from 118 patients were included. Subjective refraction and corneal topography were examined preoperatively, at 1 and 12 months postoperatively. The eyes were divided into the low-ORA ( ≤ 0.5 D) and high-ORA (>0.5 D) groups based on vector analysis, and into the low-TIA (≥0.75D and <2 D) and the high-TIA (≥2 D and ≤ 4 D) groups according to preoperative refractive astigmatism. Correction index (CI) and index of success (IOS) were compared between different groups. RESULTS: All surgeries were uneventful, and no complications occurred during follow-up. At 1 and 12 months postoperatively, no significant differences were found in CI or IOS values between the high and low ORA groups, while significantly higher CI and lower IOS were detected in the high-TIA group than in the low-TIA group (P < 0.05). No significant difference was found in CI between 1 and 12 months postoperatively in either group (P > 0.05). However, significantly lower IOS was found at 12 months compared with 1 month postoperatively for each group (P < 0.05). CONCLUSIONS: Toric implantable collamer lens (TICL) implantation is effective in correcting myopic astigmatism and is more effective in eyes with high TIA, while ORA has a minor effect. Frontiers Media S.A. 2022-01-21 /pmc/articles/PMC8813979/ /pubmed/35127737 http://dx.doi.org/10.3389/fmed.2021.737358 Text en Copyright © 2022 Zhao, Zhao, Yang, Sun, Qian, Wang and Zhou. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Medicine Zhao, Jing Zhao, Jiao Yang, Wen Sun, Ling Qian, Yishan Wang, Xiaoying Zhou, Xingtao Influence of Ocular Residual Astigmatism and Target-Induced Astigmatism on the Efficacy of the Implantation of a Toric Implantable Collamer Lens With Central Hole for Myopic Astigmatism Correction |
title | Influence of Ocular Residual Astigmatism and Target-Induced Astigmatism on the Efficacy of the Implantation of a Toric Implantable Collamer Lens With Central Hole for Myopic Astigmatism Correction |
title_full | Influence of Ocular Residual Astigmatism and Target-Induced Astigmatism on the Efficacy of the Implantation of a Toric Implantable Collamer Lens With Central Hole for Myopic Astigmatism Correction |
title_fullStr | Influence of Ocular Residual Astigmatism and Target-Induced Astigmatism on the Efficacy of the Implantation of a Toric Implantable Collamer Lens With Central Hole for Myopic Astigmatism Correction |
title_full_unstemmed | Influence of Ocular Residual Astigmatism and Target-Induced Astigmatism on the Efficacy of the Implantation of a Toric Implantable Collamer Lens With Central Hole for Myopic Astigmatism Correction |
title_short | Influence of Ocular Residual Astigmatism and Target-Induced Astigmatism on the Efficacy of the Implantation of a Toric Implantable Collamer Lens With Central Hole for Myopic Astigmatism Correction |
title_sort | influence of ocular residual astigmatism and target-induced astigmatism on the efficacy of the implantation of a toric implantable collamer lens with central hole for myopic astigmatism correction |
topic | Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8813979/ https://www.ncbi.nlm.nih.gov/pubmed/35127737 http://dx.doi.org/10.3389/fmed.2021.737358 |
work_keys_str_mv | AT zhaojing influenceofocularresidualastigmatismandtargetinducedastigmatismontheefficacyoftheimplantationofatoricimplantablecollamerlenswithcentralholeformyopicastigmatismcorrection AT zhaojiao influenceofocularresidualastigmatismandtargetinducedastigmatismontheefficacyoftheimplantationofatoricimplantablecollamerlenswithcentralholeformyopicastigmatismcorrection AT yangwen influenceofocularresidualastigmatismandtargetinducedastigmatismontheefficacyoftheimplantationofatoricimplantablecollamerlenswithcentralholeformyopicastigmatismcorrection AT sunling influenceofocularresidualastigmatismandtargetinducedastigmatismontheefficacyoftheimplantationofatoricimplantablecollamerlenswithcentralholeformyopicastigmatismcorrection AT qianyishan influenceofocularresidualastigmatismandtargetinducedastigmatismontheefficacyoftheimplantationofatoricimplantablecollamerlenswithcentralholeformyopicastigmatismcorrection AT wangxiaoying influenceofocularresidualastigmatismandtargetinducedastigmatismontheefficacyoftheimplantationofatoricimplantablecollamerlenswithcentralholeformyopicastigmatismcorrection AT zhouxingtao influenceofocularresidualastigmatismandtargetinducedastigmatismontheefficacyoftheimplantationofatoricimplantablecollamerlenswithcentralholeformyopicastigmatismcorrection |