Cargando…
Deconvolution of Tc-99m-Mercaptoacetyltriglycine Renograms with the Concomitant Use of a Sparse Legendre Polynomial Representation and the Moore-Penrose Pseudo-inverse
OBJECTIVES: This study aimed to introduce an improved deconvolution technique for Tc-99m-mercaptoacetyltriglycine renograms based on the combination of a sparse Legendre polynomial representation and the Moore-Penrose inversion matrix (LG). This method reduces the effect of noise on the measurement...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Galenos Publishing
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8814546/ https://www.ncbi.nlm.nih.gov/pubmed/35114746 http://dx.doi.org/10.4274/mirt.galenos.2021.17363 |
_version_ | 1784645085683515392 |
---|---|
author | Destine, Michel Hanin, François-Xavier Mathieu, Isabelle Willemart, Bernard Seret, Alain |
author_facet | Destine, Michel Hanin, François-Xavier Mathieu, Isabelle Willemart, Bernard Seret, Alain |
author_sort | Destine, Michel |
collection | PubMed |
description | OBJECTIVES: This study aimed to introduce an improved deconvolution technique for Tc-99m-mercaptoacetyltriglycine renograms based on the combination of a sparse Legendre polynomial representation and the Moore-Penrose inversion matrix (LG). This method reduces the effect of noise on the measurement of renal retention function transit time (TT). METHODS: The stability and accuracy of the proposed method were tested using a renal database containing Monte Carlo-simulated studies and real adult patient data. Two clinical parameters, namely, split function (SF) and mean TT (meanTT), obtained with LG were compared with values calculated with the established method that combines matrix deconvolution and a three-point linear smoothing (F121) as recommended by the 2008 International Scientific Committee of Radionuclides in Nephrourology consensus on renal TT measurements. RESULTS: For simulated data, the root mean square error (RMSE) between the theoretical non-noisy renal retention curve (RRC) and the results of the deconvolution methods applied to the noisy RRC were up to two times lower with LG (p<0.001). The RMSE of the reconvoluted renogram and the theoretical one was also lower for LG (p<0.001) and showed better preservation of the original signal. The SF was neither improved nor degraded by the proposed method. For patient data, no statistically significant difference was found between the SF for the LG method compared with the database values, and the meanTT better agreed with the physician’s diagnosis than the matrix or clinical software (Hermes) outputs. A visual improvement of the RRC was also observed. CONCLUSION: By combining the sparse Legendre representation of the renogram curves and the Moore-Penrose matrix inverse techniques, we obtained improved noise reduction in the deconvoluted data, leading to better elimination of non-physiological signals -as negative values- and the avoidance of the smear effect of conventional smoothing on the vascular peak, which both influenced the meanTT measurement. |
format | Online Article Text |
id | pubmed-8814546 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Galenos Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-88145462022-02-16 Deconvolution of Tc-99m-Mercaptoacetyltriglycine Renograms with the Concomitant Use of a Sparse Legendre Polynomial Representation and the Moore-Penrose Pseudo-inverse Destine, Michel Hanin, François-Xavier Mathieu, Isabelle Willemart, Bernard Seret, Alain Mol Imaging Radionucl Ther Original Article OBJECTIVES: This study aimed to introduce an improved deconvolution technique for Tc-99m-mercaptoacetyltriglycine renograms based on the combination of a sparse Legendre polynomial representation and the Moore-Penrose inversion matrix (LG). This method reduces the effect of noise on the measurement of renal retention function transit time (TT). METHODS: The stability and accuracy of the proposed method were tested using a renal database containing Monte Carlo-simulated studies and real adult patient data. Two clinical parameters, namely, split function (SF) and mean TT (meanTT), obtained with LG were compared with values calculated with the established method that combines matrix deconvolution and a three-point linear smoothing (F121) as recommended by the 2008 International Scientific Committee of Radionuclides in Nephrourology consensus on renal TT measurements. RESULTS: For simulated data, the root mean square error (RMSE) between the theoretical non-noisy renal retention curve (RRC) and the results of the deconvolution methods applied to the noisy RRC were up to two times lower with LG (p<0.001). The RMSE of the reconvoluted renogram and the theoretical one was also lower for LG (p<0.001) and showed better preservation of the original signal. The SF was neither improved nor degraded by the proposed method. For patient data, no statistically significant difference was found between the SF for the LG method compared with the database values, and the meanTT better agreed with the physician’s diagnosis than the matrix or clinical software (Hermes) outputs. A visual improvement of the RRC was also observed. CONCLUSION: By combining the sparse Legendre representation of the renogram curves and the Moore-Penrose matrix inverse techniques, we obtained improved noise reduction in the deconvoluted data, leading to better elimination of non-physiological signals -as negative values- and the avoidance of the smear effect of conventional smoothing on the vascular peak, which both influenced the meanTT measurement. Galenos Publishing 2022-02 2022-02-02 /pmc/articles/PMC8814546/ /pubmed/35114746 http://dx.doi.org/10.4274/mirt.galenos.2021.17363 Text en ©Copyright 2022 by Turkish Society of Nuclear Medicine | Molecular Imaging and Radionuclide Therapy published by Galenos Yayınevi. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Destine, Michel Hanin, François-Xavier Mathieu, Isabelle Willemart, Bernard Seret, Alain Deconvolution of Tc-99m-Mercaptoacetyltriglycine Renograms with the Concomitant Use of a Sparse Legendre Polynomial Representation and the Moore-Penrose Pseudo-inverse |
title | Deconvolution of Tc-99m-Mercaptoacetyltriglycine Renograms with the Concomitant Use of a Sparse Legendre Polynomial Representation and the Moore-Penrose Pseudo-inverse |
title_full | Deconvolution of Tc-99m-Mercaptoacetyltriglycine Renograms with the Concomitant Use of a Sparse Legendre Polynomial Representation and the Moore-Penrose Pseudo-inverse |
title_fullStr | Deconvolution of Tc-99m-Mercaptoacetyltriglycine Renograms with the Concomitant Use of a Sparse Legendre Polynomial Representation and the Moore-Penrose Pseudo-inverse |
title_full_unstemmed | Deconvolution of Tc-99m-Mercaptoacetyltriglycine Renograms with the Concomitant Use of a Sparse Legendre Polynomial Representation and the Moore-Penrose Pseudo-inverse |
title_short | Deconvolution of Tc-99m-Mercaptoacetyltriglycine Renograms with the Concomitant Use of a Sparse Legendre Polynomial Representation and the Moore-Penrose Pseudo-inverse |
title_sort | deconvolution of tc-99m-mercaptoacetyltriglycine renograms with the concomitant use of a sparse legendre polynomial representation and the moore-penrose pseudo-inverse |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8814546/ https://www.ncbi.nlm.nih.gov/pubmed/35114746 http://dx.doi.org/10.4274/mirt.galenos.2021.17363 |
work_keys_str_mv | AT destinemichel deconvolutionoftc99mmercaptoacetyltriglycinerenogramswiththeconcomitantuseofasparselegendrepolynomialrepresentationandthemoorepenrosepseudoinverse AT haninfrancoisxavier deconvolutionoftc99mmercaptoacetyltriglycinerenogramswiththeconcomitantuseofasparselegendrepolynomialrepresentationandthemoorepenrosepseudoinverse AT mathieuisabelle deconvolutionoftc99mmercaptoacetyltriglycinerenogramswiththeconcomitantuseofasparselegendrepolynomialrepresentationandthemoorepenrosepseudoinverse AT willemartbernard deconvolutionoftc99mmercaptoacetyltriglycinerenogramswiththeconcomitantuseofasparselegendrepolynomialrepresentationandthemoorepenrosepseudoinverse AT seretalain deconvolutionoftc99mmercaptoacetyltriglycinerenogramswiththeconcomitantuseofasparselegendrepolynomialrepresentationandthemoorepenrosepseudoinverse |