Cargando…

Low-Dose Three-Dimensional Rotational Angiography for Evaluating Intracranial Aneurysms: Analysis of Image Quality and Radiation Dose

OBJECTIVE: This study aimed to evaluate the image quality and dose reduction of low-dose three-dimensional (3D) rotational angiography (RA) for evaluating intracranial aneurysms. MATERIALS AND METHODS: We retrospectively evaluated the clinical data and 3D RA datasets obtained from 146 prospectively...

Descripción completa

Detalles Bibliográficos
Autores principales: Ki, Hee Jong, Kim, Bum-soo, Kim, Jun-Ki, Choi, Jai Ho, Shin, Yong Sam, Choi, Yangsean, Shin, Na-Young, Jang, Jinhee, Ahn, Kook-jin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8814704/
https://www.ncbi.nlm.nih.gov/pubmed/35029071
http://dx.doi.org/10.3348/kjr.2021.0162
_version_ 1784645120871628800
author Ki, Hee Jong
Kim, Bum-soo
Kim, Jun-Ki
Choi, Jai Ho
Shin, Yong Sam
Choi, Yangsean
Shin, Na-Young
Jang, Jinhee
Ahn, Kook-jin
author_facet Ki, Hee Jong
Kim, Bum-soo
Kim, Jun-Ki
Choi, Jai Ho
Shin, Yong Sam
Choi, Yangsean
Shin, Na-Young
Jang, Jinhee
Ahn, Kook-jin
author_sort Ki, Hee Jong
collection PubMed
description OBJECTIVE: This study aimed to evaluate the image quality and dose reduction of low-dose three-dimensional (3D) rotational angiography (RA) for evaluating intracranial aneurysms. MATERIALS AND METHODS: We retrospectively evaluated the clinical data and 3D RA datasets obtained from 146 prospectively registered patients (male:female, 46:100; median age, 58 years; range, 19–81 years). The subjective image quality of 79 examinations obtained from a conventional method and 67 examinations obtained from a low-dose (5-seconds and 0.10-µGy/frame) method was assessed by two neurointerventionists using a 3-point scale for four evaluation criteria. The total image quality score was then obtained as the average of the four scores. The image quality scores were compared between the two methods using a noninferiority statistical testing, with a margin of -0.2 (i.e., score of low-dose group – score of conventional group). For the evaluation of dose reduction, dose-area product (DAP) and air kerma (AK) were analyzed and compared between the two groups. RESULTS: The mean total image quality score ± standard deviation of the 3D RA was 2.97 ± 0.17 by reader 1 and 2.95 ± 0.20 by reader 2 for conventional group and 2.92 ± 0.30 and 2.95 ± 0.22, respectively, for low-dose group. The image quality of the 3D RA in the low-dose group was not inferior to that of the conventional group according to the total image quality score as well as individual scores for the four criteria in both readers. The mean DAP and AK per rotation were 5.87 Gy-cm(2) and 0.56 Gy, respectively, in the conventional group, and 1.32 Gy-cm(2) (p < 0.001) and 0.17 Gy (p < 0.001), respectively, in the low-dose group. CONCLUSION: Low-dose 3D RA was not inferior in image quality and reduced the radiation dose by 70%–77% compared to the conventional 3D RA in evaluating intracranial aneurysms.
format Online
Article
Text
id pubmed-8814704
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-88147042022-02-10 Low-Dose Three-Dimensional Rotational Angiography for Evaluating Intracranial Aneurysms: Analysis of Image Quality and Radiation Dose Ki, Hee Jong Kim, Bum-soo Kim, Jun-Ki Choi, Jai Ho Shin, Yong Sam Choi, Yangsean Shin, Na-Young Jang, Jinhee Ahn, Kook-jin Korean J Radiol Neurointervention OBJECTIVE: This study aimed to evaluate the image quality and dose reduction of low-dose three-dimensional (3D) rotational angiography (RA) for evaluating intracranial aneurysms. MATERIALS AND METHODS: We retrospectively evaluated the clinical data and 3D RA datasets obtained from 146 prospectively registered patients (male:female, 46:100; median age, 58 years; range, 19–81 years). The subjective image quality of 79 examinations obtained from a conventional method and 67 examinations obtained from a low-dose (5-seconds and 0.10-µGy/frame) method was assessed by two neurointerventionists using a 3-point scale for four evaluation criteria. The total image quality score was then obtained as the average of the four scores. The image quality scores were compared between the two methods using a noninferiority statistical testing, with a margin of -0.2 (i.e., score of low-dose group – score of conventional group). For the evaluation of dose reduction, dose-area product (DAP) and air kerma (AK) were analyzed and compared between the two groups. RESULTS: The mean total image quality score ± standard deviation of the 3D RA was 2.97 ± 0.17 by reader 1 and 2.95 ± 0.20 by reader 2 for conventional group and 2.92 ± 0.30 and 2.95 ± 0.22, respectively, for low-dose group. The image quality of the 3D RA in the low-dose group was not inferior to that of the conventional group according to the total image quality score as well as individual scores for the four criteria in both readers. The mean DAP and AK per rotation were 5.87 Gy-cm(2) and 0.56 Gy, respectively, in the conventional group, and 1.32 Gy-cm(2) (p < 0.001) and 0.17 Gy (p < 0.001), respectively, in the low-dose group. CONCLUSION: Low-dose 3D RA was not inferior in image quality and reduced the radiation dose by 70%–77% compared to the conventional 3D RA in evaluating intracranial aneurysms. The Korean Society of Radiology 2022-02 2022-01-04 /pmc/articles/PMC8814704/ /pubmed/35029071 http://dx.doi.org/10.3348/kjr.2021.0162 Text en Copyright © 2022 The Korean Society of Radiology https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Neurointervention
Ki, Hee Jong
Kim, Bum-soo
Kim, Jun-Ki
Choi, Jai Ho
Shin, Yong Sam
Choi, Yangsean
Shin, Na-Young
Jang, Jinhee
Ahn, Kook-jin
Low-Dose Three-Dimensional Rotational Angiography for Evaluating Intracranial Aneurysms: Analysis of Image Quality and Radiation Dose
title Low-Dose Three-Dimensional Rotational Angiography for Evaluating Intracranial Aneurysms: Analysis of Image Quality and Radiation Dose
title_full Low-Dose Three-Dimensional Rotational Angiography for Evaluating Intracranial Aneurysms: Analysis of Image Quality and Radiation Dose
title_fullStr Low-Dose Three-Dimensional Rotational Angiography for Evaluating Intracranial Aneurysms: Analysis of Image Quality and Radiation Dose
title_full_unstemmed Low-Dose Three-Dimensional Rotational Angiography for Evaluating Intracranial Aneurysms: Analysis of Image Quality and Radiation Dose
title_short Low-Dose Three-Dimensional Rotational Angiography for Evaluating Intracranial Aneurysms: Analysis of Image Quality and Radiation Dose
title_sort low-dose three-dimensional rotational angiography for evaluating intracranial aneurysms: analysis of image quality and radiation dose
topic Neurointervention
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8814704/
https://www.ncbi.nlm.nih.gov/pubmed/35029071
http://dx.doi.org/10.3348/kjr.2021.0162
work_keys_str_mv AT kiheejong lowdosethreedimensionalrotationalangiographyforevaluatingintracranialaneurysmsanalysisofimagequalityandradiationdose
AT kimbumsoo lowdosethreedimensionalrotationalangiographyforevaluatingintracranialaneurysmsanalysisofimagequalityandradiationdose
AT kimjunki lowdosethreedimensionalrotationalangiographyforevaluatingintracranialaneurysmsanalysisofimagequalityandradiationdose
AT choijaiho lowdosethreedimensionalrotationalangiographyforevaluatingintracranialaneurysmsanalysisofimagequalityandradiationdose
AT shinyongsam lowdosethreedimensionalrotationalangiographyforevaluatingintracranialaneurysmsanalysisofimagequalityandradiationdose
AT choiyangsean lowdosethreedimensionalrotationalangiographyforevaluatingintracranialaneurysmsanalysisofimagequalityandradiationdose
AT shinnayoung lowdosethreedimensionalrotationalangiographyforevaluatingintracranialaneurysmsanalysisofimagequalityandradiationdose
AT jangjinhee lowdosethreedimensionalrotationalangiographyforevaluatingintracranialaneurysmsanalysisofimagequalityandradiationdose
AT ahnkookjin lowdosethreedimensionalrotationalangiographyforevaluatingintracranialaneurysmsanalysisofimagequalityandradiationdose