Cargando…
Trajectories of hypoxemia and pulmonary mechanics of COVID-19 ARDS in the NorthCARDS dataset
BACKGROUND: Understanding heterogeneity seen in patients with COVIDARDS and comparing to non-COVIDARDS may inform tailored treatments. METHODS: A multidisciplinary team of frontline clinicians and data scientists worked to create the Northwell COVIDARDS dataset (NorthCARDS) leveraging over 11,542 CO...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8814783/ https://www.ncbi.nlm.nih.gov/pubmed/35120478 http://dx.doi.org/10.1186/s12890-021-01732-y |
Sumario: | BACKGROUND: Understanding heterogeneity seen in patients with COVIDARDS and comparing to non-COVIDARDS may inform tailored treatments. METHODS: A multidisciplinary team of frontline clinicians and data scientists worked to create the Northwell COVIDARDS dataset (NorthCARDS) leveraging over 11,542 COVID-19 hospital admissions. The data was then summarized to examine descriptive differences based on clinically meaningful categories of lung compliance, and to examine trends in oxygenation. FINDINGS: Of the 1536 COVIDARDS patients in the NorthCARDS dataset, there were 531 (34.6%) who had very low lung compliance (< 20 ml/cmH(2)O), 970 (63.2%) with low-normal compliance (20–50 ml/cmH(2)O), and 35 (2.2%) with high lung compliance (> 50 ml/cmH(2)O). The very low compliance group had double the median time to intubation compared to the low-normal group (107.3 h (IQR 25.8, 239.2) vs. 39.5 h (IQR 5.4, 91.6)). Overall, 68.8% (n = 1057) of the patients died during hospitalization. In comparison to non-COVIDARDS reports, there were less patients in the high compliance category (2.2% vs. 12%, compliance ≥ 50 mL/cmH20), and more patients with P/F ≤ 150 (59.8% vs. 45.6%). There is a statistically significant correlation between compliance and P/F ratio. The Oxygenation Index is the highest in the very low compliance group (12.51, SD(6.15)), and lowest in high compliance group (8.78, SD(4.93)). CONCLUSIONS: The respiratory system compliance distribution of COVIDARDS is similar to non-COVIDARDS. In some patients, there may be a relation between time to intubation and duration of high levels of supplemental oxygen treatment on trajectory of lung compliance. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12890-021-01732-y. |
---|