Cargando…

Enhancing the Efficacy of Microwave Blanching-cum-black Mould Inactivation of Whole Garlic (Allium sativum L.) Bulbs Using Ultrasound: Higher Inactivation of Peroxidase, Polyphenol Oxidase, and Aspergillus niger at Lower Processing Temperatures

The freshly harvested whole garlic bulbs require the inactivation of peroxidase (POD), polyphenol oxidase (PPO), and Aspergillus niger. However, the conventional hot water blanching and modern pretreatment like ultrasound (US) and microwave (MW) cannot individually inactivate both the enzymes and As...

Descripción completa

Detalles Bibliográficos
Autores principales: Kar, Sudarshanna, Sutar, P. P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8815399/
https://www.ncbi.nlm.nih.gov/pubmed/35154557
http://dx.doi.org/10.1007/s11947-022-02769-5
_version_ 1784645273601966080
author Kar, Sudarshanna
Sutar, P. P.
author_facet Kar, Sudarshanna
Sutar, P. P.
author_sort Kar, Sudarshanna
collection PubMed
description The freshly harvested whole garlic bulbs require the inactivation of peroxidase (POD), polyphenol oxidase (PPO), and Aspergillus niger. However, the conventional hot water blanching and modern pretreatment like ultrasound (US) and microwave (MW) cannot individually inactivate both the enzymes and Aspergillus niger to the desired levels without compromising the quality of the garlic due to either of the higher process temperatures (> 85 °C) or prolonged treatment times. Therefore, a two-stage sequential US followed by MW pretreatment for garlic bulbs was developed for simultaneous inactivation of POD, PPO, and Aspergillus niger to the desired levels and overcome the individual pretreatment drawbacks. The separate experiments were conducted for US and MW pretreatment using central composite design, and optimization was carried out using response surface methodology. When temperature constraint was considered during optimization, the US was able to reduce POD, PPO, and Aspergillus niger by 80.87%, 93.80%, and 2.60 logs, respectively, whereas MW reduced POD, PPO, and Aspergillus niger by 77.84%, 77.04%, and 1.90 logs, respectively. The US treatment (58.43 WL(−1) ultrasound power density for 40 min with an initial bath temperature of 60 °C) followed by MW treatment (3 Wg(−1) MW power density for 120 s) resulted in 90.37% POD and 92.38% PPO inactivation with 2.62 log reduction in Aspergillus niger. The maximum temperature reached in US + MW process was 83 °C which ensured no severe thermal damage to the garlic bulbs. The scanning electron microscopic images indicated that ultrasonication induced the porous structure in garlic and helped microwaves increase the product temperature rapidly and achieve the higher inactivation of enzymes and Aspergillus niger. Thus, the US was found to be enhancing the efficacy of the MW heating process.
format Online
Article
Text
id pubmed-8815399
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-88153992022-02-07 Enhancing the Efficacy of Microwave Blanching-cum-black Mould Inactivation of Whole Garlic (Allium sativum L.) Bulbs Using Ultrasound: Higher Inactivation of Peroxidase, Polyphenol Oxidase, and Aspergillus niger at Lower Processing Temperatures Kar, Sudarshanna Sutar, P. P. Food Bioproc Tech Original Research The freshly harvested whole garlic bulbs require the inactivation of peroxidase (POD), polyphenol oxidase (PPO), and Aspergillus niger. However, the conventional hot water blanching and modern pretreatment like ultrasound (US) and microwave (MW) cannot individually inactivate both the enzymes and Aspergillus niger to the desired levels without compromising the quality of the garlic due to either of the higher process temperatures (> 85 °C) or prolonged treatment times. Therefore, a two-stage sequential US followed by MW pretreatment for garlic bulbs was developed for simultaneous inactivation of POD, PPO, and Aspergillus niger to the desired levels and overcome the individual pretreatment drawbacks. The separate experiments were conducted for US and MW pretreatment using central composite design, and optimization was carried out using response surface methodology. When temperature constraint was considered during optimization, the US was able to reduce POD, PPO, and Aspergillus niger by 80.87%, 93.80%, and 2.60 logs, respectively, whereas MW reduced POD, PPO, and Aspergillus niger by 77.84%, 77.04%, and 1.90 logs, respectively. The US treatment (58.43 WL(−1) ultrasound power density for 40 min with an initial bath temperature of 60 °C) followed by MW treatment (3 Wg(−1) MW power density for 120 s) resulted in 90.37% POD and 92.38% PPO inactivation with 2.62 log reduction in Aspergillus niger. The maximum temperature reached in US + MW process was 83 °C which ensured no severe thermal damage to the garlic bulbs. The scanning electron microscopic images indicated that ultrasonication induced the porous structure in garlic and helped microwaves increase the product temperature rapidly and achieve the higher inactivation of enzymes and Aspergillus niger. Thus, the US was found to be enhancing the efficacy of the MW heating process. Springer US 2022-02-04 2022 /pmc/articles/PMC8815399/ /pubmed/35154557 http://dx.doi.org/10.1007/s11947-022-02769-5 Text en © The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature 2022 This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.
spellingShingle Original Research
Kar, Sudarshanna
Sutar, P. P.
Enhancing the Efficacy of Microwave Blanching-cum-black Mould Inactivation of Whole Garlic (Allium sativum L.) Bulbs Using Ultrasound: Higher Inactivation of Peroxidase, Polyphenol Oxidase, and Aspergillus niger at Lower Processing Temperatures
title Enhancing the Efficacy of Microwave Blanching-cum-black Mould Inactivation of Whole Garlic (Allium sativum L.) Bulbs Using Ultrasound: Higher Inactivation of Peroxidase, Polyphenol Oxidase, and Aspergillus niger at Lower Processing Temperatures
title_full Enhancing the Efficacy of Microwave Blanching-cum-black Mould Inactivation of Whole Garlic (Allium sativum L.) Bulbs Using Ultrasound: Higher Inactivation of Peroxidase, Polyphenol Oxidase, and Aspergillus niger at Lower Processing Temperatures
title_fullStr Enhancing the Efficacy of Microwave Blanching-cum-black Mould Inactivation of Whole Garlic (Allium sativum L.) Bulbs Using Ultrasound: Higher Inactivation of Peroxidase, Polyphenol Oxidase, and Aspergillus niger at Lower Processing Temperatures
title_full_unstemmed Enhancing the Efficacy of Microwave Blanching-cum-black Mould Inactivation of Whole Garlic (Allium sativum L.) Bulbs Using Ultrasound: Higher Inactivation of Peroxidase, Polyphenol Oxidase, and Aspergillus niger at Lower Processing Temperatures
title_short Enhancing the Efficacy of Microwave Blanching-cum-black Mould Inactivation of Whole Garlic (Allium sativum L.) Bulbs Using Ultrasound: Higher Inactivation of Peroxidase, Polyphenol Oxidase, and Aspergillus niger at Lower Processing Temperatures
title_sort enhancing the efficacy of microwave blanching-cum-black mould inactivation of whole garlic (allium sativum l.) bulbs using ultrasound: higher inactivation of peroxidase, polyphenol oxidase, and aspergillus niger at lower processing temperatures
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8815399/
https://www.ncbi.nlm.nih.gov/pubmed/35154557
http://dx.doi.org/10.1007/s11947-022-02769-5
work_keys_str_mv AT karsudarshanna enhancingtheefficacyofmicrowaveblanchingcumblackmouldinactivationofwholegarlicalliumsativumlbulbsusingultrasoundhigherinactivationofperoxidasepolyphenoloxidaseandaspergillusnigeratlowerprocessingtemperatures
AT sutarpp enhancingtheefficacyofmicrowaveblanchingcumblackmouldinactivationofwholegarlicalliumsativumlbulbsusingultrasoundhigherinactivationofperoxidasepolyphenoloxidaseandaspergillusnigeratlowerprocessingtemperatures