Cargando…

Evaluation of Autofluorescence in Identifying Parathyroid Glands by Measuring Parathyroid Hormone in Fine-Needle Biopsy Washings

BACKGROUND: Near-infrared autofluorescence imaging has potentially great value for assisting endocrine surgeons in identifying parathyroid glands and may dramatically change the surgical strategy of endocrine surgeons in thyroid surgery. This study is designed to objectively evaluate the role of nea...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Zhen, Ma, Run-sheng, Jia, Jun-li, Wang, Tao, Zuo, Dao-hong, Yin, De-tao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8815459/
https://www.ncbi.nlm.nih.gov/pubmed/35126316
http://dx.doi.org/10.3389/fendo.2021.819503
_version_ 1784645284389715968
author Liu, Zhen
Ma, Run-sheng
Jia, Jun-li
Wang, Tao
Zuo, Dao-hong
Yin, De-tao
author_facet Liu, Zhen
Ma, Run-sheng
Jia, Jun-li
Wang, Tao
Zuo, Dao-hong
Yin, De-tao
author_sort Liu, Zhen
collection PubMed
description BACKGROUND: Near-infrared autofluorescence imaging has potentially great value for assisting endocrine surgeons in identifying parathyroid glands and may dramatically change the surgical strategy of endocrine surgeons in thyroid surgery. This study is designed to objectively evaluate the role of near-infrared autofluorescence imaging in identifying parathyroid glands during thyroid surgery by measuring intraoperative parathyroid hormone in fine-needle aspiration biopsy washings. METHODS: This study was conducted at a tertiary referral teaching hospital in China from February 2020 to June 2020. Patients undergoing total thyroidectomy with or without neck lymph node dissection were consecutively included. The surgeon used near-infrared autofluorescence imaging to identify parathyroid glands during thyroid surgery and confirmed suspicious parathyroid tissues by measuring their intraoperative parathyroid hormone. Nanocarbon was injected into the thyroid gland if the thyroid autofluorescence intensity was too strong. The sensitivity and accuracy of near-infrared autofluorescence imaging and vision for identifying parathyroid glands, and the difference in autofluorescence intensity in various tissues were the main outcomes. RESULTS: Overall, 238 patients completed the trial. Based on the pathological and aIOPTH results, the sensitivity of near-infrared autofluorescence imaging for detecting parathyroid glands (568 of 596 parathyroid glands; 95.30%)was significantly higher than that of vision (517 of 596 parathyroid glands; 86.74%, P<.001). The accuracy of near-infrared autofluorescence imaging (764 of 841 tissues; 90.84%) was significantly higher than that of vision (567 of 841 tissues; 67.42%, P<.001) when the evaluations of certain tissues were inconsistent. There was a significant difference between the autofluorescence intensity of the parathyroid glands and that of the lymph nodes (74.19 ± 17.82 vs 33.97 ± 10.64, P<.001). CONCLUSION: The use of near-infrared autofluorescence imaging, along with intraoperative parathyroid hormone and nanocarbon for the identification of parathyroid glands in thyroid surgery may increase the number of confirmed parathyroid glands. Using near-infrared autofluorescence imaging can effectively distinguish lymph nodes and parathyroid glands during lymph node dissection.
format Online
Article
Text
id pubmed-8815459
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-88154592022-02-05 Evaluation of Autofluorescence in Identifying Parathyroid Glands by Measuring Parathyroid Hormone in Fine-Needle Biopsy Washings Liu, Zhen Ma, Run-sheng Jia, Jun-li Wang, Tao Zuo, Dao-hong Yin, De-tao Front Endocrinol (Lausanne) Endocrinology BACKGROUND: Near-infrared autofluorescence imaging has potentially great value for assisting endocrine surgeons in identifying parathyroid glands and may dramatically change the surgical strategy of endocrine surgeons in thyroid surgery. This study is designed to objectively evaluate the role of near-infrared autofluorescence imaging in identifying parathyroid glands during thyroid surgery by measuring intraoperative parathyroid hormone in fine-needle aspiration biopsy washings. METHODS: This study was conducted at a tertiary referral teaching hospital in China from February 2020 to June 2020. Patients undergoing total thyroidectomy with or without neck lymph node dissection were consecutively included. The surgeon used near-infrared autofluorescence imaging to identify parathyroid glands during thyroid surgery and confirmed suspicious parathyroid tissues by measuring their intraoperative parathyroid hormone. Nanocarbon was injected into the thyroid gland if the thyroid autofluorescence intensity was too strong. The sensitivity and accuracy of near-infrared autofluorescence imaging and vision for identifying parathyroid glands, and the difference in autofluorescence intensity in various tissues were the main outcomes. RESULTS: Overall, 238 patients completed the trial. Based on the pathological and aIOPTH results, the sensitivity of near-infrared autofluorescence imaging for detecting parathyroid glands (568 of 596 parathyroid glands; 95.30%)was significantly higher than that of vision (517 of 596 parathyroid glands; 86.74%, P<.001). The accuracy of near-infrared autofluorescence imaging (764 of 841 tissues; 90.84%) was significantly higher than that of vision (567 of 841 tissues; 67.42%, P<.001) when the evaluations of certain tissues were inconsistent. There was a significant difference between the autofluorescence intensity of the parathyroid glands and that of the lymph nodes (74.19 ± 17.82 vs 33.97 ± 10.64, P<.001). CONCLUSION: The use of near-infrared autofluorescence imaging, along with intraoperative parathyroid hormone and nanocarbon for the identification of parathyroid glands in thyroid surgery may increase the number of confirmed parathyroid glands. Using near-infrared autofluorescence imaging can effectively distinguish lymph nodes and parathyroid glands during lymph node dissection. Frontiers Media S.A. 2022-01-21 /pmc/articles/PMC8815459/ /pubmed/35126316 http://dx.doi.org/10.3389/fendo.2021.819503 Text en Copyright © 2022 Liu, Ma, Jia, Wang, Zuo and Yin https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Endocrinology
Liu, Zhen
Ma, Run-sheng
Jia, Jun-li
Wang, Tao
Zuo, Dao-hong
Yin, De-tao
Evaluation of Autofluorescence in Identifying Parathyroid Glands by Measuring Parathyroid Hormone in Fine-Needle Biopsy Washings
title Evaluation of Autofluorescence in Identifying Parathyroid Glands by Measuring Parathyroid Hormone in Fine-Needle Biopsy Washings
title_full Evaluation of Autofluorescence in Identifying Parathyroid Glands by Measuring Parathyroid Hormone in Fine-Needle Biopsy Washings
title_fullStr Evaluation of Autofluorescence in Identifying Parathyroid Glands by Measuring Parathyroid Hormone in Fine-Needle Biopsy Washings
title_full_unstemmed Evaluation of Autofluorescence in Identifying Parathyroid Glands by Measuring Parathyroid Hormone in Fine-Needle Biopsy Washings
title_short Evaluation of Autofluorescence in Identifying Parathyroid Glands by Measuring Parathyroid Hormone in Fine-Needle Biopsy Washings
title_sort evaluation of autofluorescence in identifying parathyroid glands by measuring parathyroid hormone in fine-needle biopsy washings
topic Endocrinology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8815459/
https://www.ncbi.nlm.nih.gov/pubmed/35126316
http://dx.doi.org/10.3389/fendo.2021.819503
work_keys_str_mv AT liuzhen evaluationofautofluorescenceinidentifyingparathyroidglandsbymeasuringparathyroidhormoneinfineneedlebiopsywashings
AT marunsheng evaluationofautofluorescenceinidentifyingparathyroidglandsbymeasuringparathyroidhormoneinfineneedlebiopsywashings
AT jiajunli evaluationofautofluorescenceinidentifyingparathyroidglandsbymeasuringparathyroidhormoneinfineneedlebiopsywashings
AT wangtao evaluationofautofluorescenceinidentifyingparathyroidglandsbymeasuringparathyroidhormoneinfineneedlebiopsywashings
AT zuodaohong evaluationofautofluorescenceinidentifyingparathyroidglandsbymeasuringparathyroidhormoneinfineneedlebiopsywashings
AT yindetao evaluationofautofluorescenceinidentifyingparathyroidglandsbymeasuringparathyroidhormoneinfineneedlebiopsywashings