Cargando…
Preliminary experience with continuous right ventricular pressure and transesophageal echocardiography monitoring in orthotopic liver transplantation
BACKGROUND: Despite increasing attention in the cardiac anesthesiology literature, continuous measurement of right ventricular pressure using a pulmonary artery catheter has not been described in orthotopic liver transplantation, despite similarities in the anesthetic approach to the two populations...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8815904/ https://www.ncbi.nlm.nih.gov/pubmed/35120144 http://dx.doi.org/10.1371/journal.pone.0263386 |
_version_ | 1784645334308225024 |
---|---|
author | Miles, Lachlan F. Couture, Etienne J. Potes, Cristhian Makar, Timothy Fernando, Malindra C. Hungenahally, Akshay Mathieson, Matthew D. Perlman, Hannah Perini, Marcos V. Thind, Dilraj Weinberg, Laurence Denault, André Y. |
author_facet | Miles, Lachlan F. Couture, Etienne J. Potes, Cristhian Makar, Timothy Fernando, Malindra C. Hungenahally, Akshay Mathieson, Matthew D. Perlman, Hannah Perini, Marcos V. Thind, Dilraj Weinberg, Laurence Denault, André Y. |
author_sort | Miles, Lachlan F. |
collection | PubMed |
description | BACKGROUND: Despite increasing attention in the cardiac anesthesiology literature, continuous measurement of right ventricular pressure using a pulmonary artery catheter has not been described in orthotopic liver transplantation, despite similarities in the anesthetic approach to the two populations. We describe our preliminary experience with this technique in orthotopic liver transplantation, and by combining various derived measures with trans-esophageal echocardiography, make some early observations regarding the response of these measures of right ventricular function during the procedure. METHODS: In this case series, ten patients (five men and five women) undergoing orthotopic liver transplantation in our institution had their surgeries performed while monitored with a pulmonary artery catheter with continuous right ventricular port transduction and trans-esophageal echocardiography. We recorded various right ventricular waveform (early-to-end diastolic pressure difference, right ventricular outflow tract gradient, right ventricular dP/dT and right ventricular end-diastolic pressure) and echocardiographic (right ventricular fractional area change, tricuspid annular plane systolic excursion, right ventricular lateral wall strain) and described their change relative to baseline at timepoints five minutes before and after portal vein reperfusion, immediately after hepatic artery reperfusion and on abdominal closure. RESULTS: Except for tricuspid annular plane systolic excursion at five minutes prior to reperfusion (mean −0.8 cm; 95% CI−1.4, –0.3; p = 0.007), no echocardiographic metric was statistically significantly different at any timepoint relative to baseline. In contrast, changes in right ventricular outflow tract gradient and right ventricular dP/dt were highly significant at multiple timepoints, generally peaking immediately before or after reperfusion before reducing, but not returning to baseline in the neohepatic phase. Nine of 10 participants in this series demonstrated a degree of dynamic right ventricular outflow tract obstruction, which met criteria for hemodynamic significance (> 25 mmHg) in two participants. These changes were not materially affected by cardiac index. CONCLUSIONS: Dynamic right ventricular outflow tract obstruction of varying severity appears common in patients undergoing orthotopic liver transplantation. These results are hypothesis generating and will form the basis of future prospective research. |
format | Online Article Text |
id | pubmed-8815904 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-88159042022-02-05 Preliminary experience with continuous right ventricular pressure and transesophageal echocardiography monitoring in orthotopic liver transplantation Miles, Lachlan F. Couture, Etienne J. Potes, Cristhian Makar, Timothy Fernando, Malindra C. Hungenahally, Akshay Mathieson, Matthew D. Perlman, Hannah Perini, Marcos V. Thind, Dilraj Weinberg, Laurence Denault, André Y. PLoS One Research Article BACKGROUND: Despite increasing attention in the cardiac anesthesiology literature, continuous measurement of right ventricular pressure using a pulmonary artery catheter has not been described in orthotopic liver transplantation, despite similarities in the anesthetic approach to the two populations. We describe our preliminary experience with this technique in orthotopic liver transplantation, and by combining various derived measures with trans-esophageal echocardiography, make some early observations regarding the response of these measures of right ventricular function during the procedure. METHODS: In this case series, ten patients (five men and five women) undergoing orthotopic liver transplantation in our institution had their surgeries performed while monitored with a pulmonary artery catheter with continuous right ventricular port transduction and trans-esophageal echocardiography. We recorded various right ventricular waveform (early-to-end diastolic pressure difference, right ventricular outflow tract gradient, right ventricular dP/dT and right ventricular end-diastolic pressure) and echocardiographic (right ventricular fractional area change, tricuspid annular plane systolic excursion, right ventricular lateral wall strain) and described their change relative to baseline at timepoints five minutes before and after portal vein reperfusion, immediately after hepatic artery reperfusion and on abdominal closure. RESULTS: Except for tricuspid annular plane systolic excursion at five minutes prior to reperfusion (mean −0.8 cm; 95% CI−1.4, –0.3; p = 0.007), no echocardiographic metric was statistically significantly different at any timepoint relative to baseline. In contrast, changes in right ventricular outflow tract gradient and right ventricular dP/dt were highly significant at multiple timepoints, generally peaking immediately before or after reperfusion before reducing, but not returning to baseline in the neohepatic phase. Nine of 10 participants in this series demonstrated a degree of dynamic right ventricular outflow tract obstruction, which met criteria for hemodynamic significance (> 25 mmHg) in two participants. These changes were not materially affected by cardiac index. CONCLUSIONS: Dynamic right ventricular outflow tract obstruction of varying severity appears common in patients undergoing orthotopic liver transplantation. These results are hypothesis generating and will form the basis of future prospective research. Public Library of Science 2022-02-04 /pmc/articles/PMC8815904/ /pubmed/35120144 http://dx.doi.org/10.1371/journal.pone.0263386 Text en © 2022 Miles et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Miles, Lachlan F. Couture, Etienne J. Potes, Cristhian Makar, Timothy Fernando, Malindra C. Hungenahally, Akshay Mathieson, Matthew D. Perlman, Hannah Perini, Marcos V. Thind, Dilraj Weinberg, Laurence Denault, André Y. Preliminary experience with continuous right ventricular pressure and transesophageal echocardiography monitoring in orthotopic liver transplantation |
title | Preliminary experience with continuous right ventricular pressure and transesophageal echocardiography monitoring in orthotopic liver transplantation |
title_full | Preliminary experience with continuous right ventricular pressure and transesophageal echocardiography monitoring in orthotopic liver transplantation |
title_fullStr | Preliminary experience with continuous right ventricular pressure and transesophageal echocardiography monitoring in orthotopic liver transplantation |
title_full_unstemmed | Preliminary experience with continuous right ventricular pressure and transesophageal echocardiography monitoring in orthotopic liver transplantation |
title_short | Preliminary experience with continuous right ventricular pressure and transesophageal echocardiography monitoring in orthotopic liver transplantation |
title_sort | preliminary experience with continuous right ventricular pressure and transesophageal echocardiography monitoring in orthotopic liver transplantation |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8815904/ https://www.ncbi.nlm.nih.gov/pubmed/35120144 http://dx.doi.org/10.1371/journal.pone.0263386 |
work_keys_str_mv | AT mileslachlanf preliminaryexperiencewithcontinuousrightventricularpressureandtransesophagealechocardiographymonitoringinorthotopiclivertransplantation AT coutureetiennej preliminaryexperiencewithcontinuousrightventricularpressureandtransesophagealechocardiographymonitoringinorthotopiclivertransplantation AT potescristhian preliminaryexperiencewithcontinuousrightventricularpressureandtransesophagealechocardiographymonitoringinorthotopiclivertransplantation AT makartimothy preliminaryexperiencewithcontinuousrightventricularpressureandtransesophagealechocardiographymonitoringinorthotopiclivertransplantation AT fernandomalindrac preliminaryexperiencewithcontinuousrightventricularpressureandtransesophagealechocardiographymonitoringinorthotopiclivertransplantation AT hungenahallyakshay preliminaryexperiencewithcontinuousrightventricularpressureandtransesophagealechocardiographymonitoringinorthotopiclivertransplantation AT mathiesonmatthewd preliminaryexperiencewithcontinuousrightventricularpressureandtransesophagealechocardiographymonitoringinorthotopiclivertransplantation AT perlmanhannah preliminaryexperiencewithcontinuousrightventricularpressureandtransesophagealechocardiographymonitoringinorthotopiclivertransplantation AT perinimarcosv preliminaryexperiencewithcontinuousrightventricularpressureandtransesophagealechocardiographymonitoringinorthotopiclivertransplantation AT thinddilraj preliminaryexperiencewithcontinuousrightventricularpressureandtransesophagealechocardiographymonitoringinorthotopiclivertransplantation AT weinberglaurence preliminaryexperiencewithcontinuousrightventricularpressureandtransesophagealechocardiographymonitoringinorthotopiclivertransplantation AT denaultandrey preliminaryexperiencewithcontinuousrightventricularpressureandtransesophagealechocardiographymonitoringinorthotopiclivertransplantation |