Precision of orthodontic cephalometric measurements on ultra low dose-low dose CBCT reconstructed cephalograms
OBJECTIVES: To analyze differences in variation of orthodontic diagnostic measurements on lateral cephalograms reconstructed from ultra low dose-low dose (ULD-LD) cone beam computed tomography (CBCT) scans (RLC) as compared to variation of measurements on standard lateral cephalograms (SLC), and to...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8816531/ https://www.ncbi.nlm.nih.gov/pubmed/34453209 http://dx.doi.org/10.1007/s00784-021-04127-9 |
_version_ | 1784645455918923776 |
---|---|
author | van Bunningen, R. H. Dijkstra, P. U. Dieters, A. van der Meer, W. J. Kuijpers-Jagtman, A. M. Ren, Y. |
author_facet | van Bunningen, R. H. Dijkstra, P. U. Dieters, A. van der Meer, W. J. Kuijpers-Jagtman, A. M. Ren, Y. |
author_sort | van Bunningen, R. H. |
collection | PubMed |
description | OBJECTIVES: To analyze differences in variation of orthodontic diagnostic measurements on lateral cephalograms reconstructed from ultra low dose-low dose (ULD-LD) cone beam computed tomography (CBCT) scans (RLC) as compared to variation of measurements on standard lateral cephalograms (SLC), and to determine if it is justifiable to replace a traditional orthodontic image set for an ULD-LD CBCT with a reconstructed lateral cephalogram. MATERIAL AND METHODS: ULD-LD CBCT images and SLCs were made of forty-three dry human skulls. From the ULD-LD CBCT dataset, a lateral cephalogram was reconstructed (RLC). Cephalometric landmarks (13 skeletal and 7 dental) were identified on both SLC and RLC twice in two sessions by two calibrated observers. Thirteen cephalometric variables were calculated. Variations of measurements, expressed as standard deviations of the 4 measurements on SLC and RLC, were analyzed using a paired sample t-test. Differences in the number of observations deviating ≥ 2.0 mm or degrees from the grand mean between SLC and RLC were analyzed using a McNemar test. RESULTS: Mean SDs for 7 out of 13 variables were significantly smaller for SLCs than those for RLCs, but differences were small. For 9 out of 13 variables, there was no significant difference between SLC and RLC for the number of measurements outside the range of 2 mm or degrees. CONCLUSIONS: Based on the lower radiation dose and the small differences in variation in cephalometric measurements on reconstructed LC compared to standard dose LC, ULD-LD CBCT with reconstructed LC should be considered for orthodontic diagnostic purposes. CLINICAL RELEVANCE: ULD-LD CBCT with reconstructed LC should be considered for orthodontic purposes. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00784-021-04127-9. |
format | Online Article Text |
id | pubmed-8816531 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-88165312022-02-17 Precision of orthodontic cephalometric measurements on ultra low dose-low dose CBCT reconstructed cephalograms van Bunningen, R. H. Dijkstra, P. U. Dieters, A. van der Meer, W. J. Kuijpers-Jagtman, A. M. Ren, Y. Clin Oral Investig Original Article OBJECTIVES: To analyze differences in variation of orthodontic diagnostic measurements on lateral cephalograms reconstructed from ultra low dose-low dose (ULD-LD) cone beam computed tomography (CBCT) scans (RLC) as compared to variation of measurements on standard lateral cephalograms (SLC), and to determine if it is justifiable to replace a traditional orthodontic image set for an ULD-LD CBCT with a reconstructed lateral cephalogram. MATERIAL AND METHODS: ULD-LD CBCT images and SLCs were made of forty-three dry human skulls. From the ULD-LD CBCT dataset, a lateral cephalogram was reconstructed (RLC). Cephalometric landmarks (13 skeletal and 7 dental) were identified on both SLC and RLC twice in two sessions by two calibrated observers. Thirteen cephalometric variables were calculated. Variations of measurements, expressed as standard deviations of the 4 measurements on SLC and RLC, were analyzed using a paired sample t-test. Differences in the number of observations deviating ≥ 2.0 mm or degrees from the grand mean between SLC and RLC were analyzed using a McNemar test. RESULTS: Mean SDs for 7 out of 13 variables were significantly smaller for SLCs than those for RLCs, but differences were small. For 9 out of 13 variables, there was no significant difference between SLC and RLC for the number of measurements outside the range of 2 mm or degrees. CONCLUSIONS: Based on the lower radiation dose and the small differences in variation in cephalometric measurements on reconstructed LC compared to standard dose LC, ULD-LD CBCT with reconstructed LC should be considered for orthodontic diagnostic purposes. CLINICAL RELEVANCE: ULD-LD CBCT with reconstructed LC should be considered for orthodontic purposes. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00784-021-04127-9. Springer Berlin Heidelberg 2021-08-28 2022 /pmc/articles/PMC8816531/ /pubmed/34453209 http://dx.doi.org/10.1007/s00784-021-04127-9 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Article van Bunningen, R. H. Dijkstra, P. U. Dieters, A. van der Meer, W. J. Kuijpers-Jagtman, A. M. Ren, Y. Precision of orthodontic cephalometric measurements on ultra low dose-low dose CBCT reconstructed cephalograms |
title | Precision of orthodontic cephalometric measurements on ultra low dose-low dose CBCT reconstructed cephalograms |
title_full | Precision of orthodontic cephalometric measurements on ultra low dose-low dose CBCT reconstructed cephalograms |
title_fullStr | Precision of orthodontic cephalometric measurements on ultra low dose-low dose CBCT reconstructed cephalograms |
title_full_unstemmed | Precision of orthodontic cephalometric measurements on ultra low dose-low dose CBCT reconstructed cephalograms |
title_short | Precision of orthodontic cephalometric measurements on ultra low dose-low dose CBCT reconstructed cephalograms |
title_sort | precision of orthodontic cephalometric measurements on ultra low dose-low dose cbct reconstructed cephalograms |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8816531/ https://www.ncbi.nlm.nih.gov/pubmed/34453209 http://dx.doi.org/10.1007/s00784-021-04127-9 |
work_keys_str_mv | AT vanbunningenrh precisionoforthodonticcephalometricmeasurementsonultralowdoselowdosecbctreconstructedcephalograms AT dijkstrapu precisionoforthodonticcephalometricmeasurementsonultralowdoselowdosecbctreconstructedcephalograms AT dietersa precisionoforthodonticcephalometricmeasurementsonultralowdoselowdosecbctreconstructedcephalograms AT vandermeerwj precisionoforthodonticcephalometricmeasurementsonultralowdoselowdosecbctreconstructedcephalograms AT kuijpersjagtmanam precisionoforthodonticcephalometricmeasurementsonultralowdoselowdosecbctreconstructedcephalograms AT reny precisionoforthodonticcephalometricmeasurementsonultralowdoselowdosecbctreconstructedcephalograms |