Cargando…

Hypersensitivity relief of MIH-affected molars using two sealing techniques: a 12-week follow-up

OBJECTIVES: The aim of this study was to compare the efficacy in reducing hypersensitivity in molar incisor hypomineralization (MIH)-affected molars immediately and over 12 weeks after sealing using two different materials (composite and glass ionomer). Furthermore, the retention rates of both mater...

Descripción completa

Detalles Bibliográficos
Autores principales: Bekes, Katrin, Amend, Stefanie, Priller, Julia, Zamek, Claudia, Stamm, Tanja, Krämer, Norbert
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8816787/
https://www.ncbi.nlm.nih.gov/pubmed/34468888
http://dx.doi.org/10.1007/s00784-021-04163-5
Descripción
Sumario:OBJECTIVES: The aim of this study was to compare the efficacy in reducing hypersensitivity in molar incisor hypomineralization (MIH)-affected molars immediately and over 12 weeks after sealing using two different materials (composite and glass ionomer). Furthermore, the retention rates of both materials were analyzed. METHODS: Thirty-nine children with two MIH-affected molars showing hypersensitivity and non-occlusal breakdowns were included. Hypersensitivity was assessed with an evaporative (air) stimulus. Both teeth were sealed by two calibrated operators using a split-mouth design with either Clinpro Sealant in combination with Scotchbond Universal (C) or Ketac Universal (K), respectively. Clinical pain assessments (Schiff Score Air Sensitivity Scale [SCASS], Visual Analog Scale [VAS]) were made at baseline (“pre”), immediately after treatment (“post”), and after 1, 4, 8, and 12 weeks. Paired t tests were calculated in each group between baseline and all other time points. RESULTS: Thirty-eight children with 76 molars completed all stages of the study. Regardless of the material used, the application of the sealant decreased hypersensitivity significantly immediately as well as throughout the 12-week recalls (all p values < 0.001). We found no statistically significant difference among both materials chosen in any of the time points evaluated. Furthermore, retention of both materials was comparable in both groups. CONCLUSIONS: Both sealant materials were able to reduce hypersensitivity successfully immediately and throughout the 12-week follow-up. Furthermore, their performance was similar in terms of retention. CLINICAL RELEVANCE: Hypersensitivity can be a major complaint in patients with MIH. This is the first study evaluating hypersensitivity relief of MIH-affected molars using two sealing techniques.