Cargando…
Reliability and diagnostic accuracy of corrected slack angle derived from 2D-SWE in quantitating muscle spasticity of stroke patients
BACKGROUND: To explore the feasibility of corrected slack angle acquired from two-dimensional shear wave elastography (2D-SWE) for quantitating the spasticity of medial gastrocnemius (MG) in stroke patients. METHODS: Consecutive stroke patients with spastic MG and matched healthy controls were recru...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8817514/ https://www.ncbi.nlm.nih.gov/pubmed/35120556 http://dx.doi.org/10.1186/s12984-022-00995-8 |
_version_ | 1784645663063015424 |
---|---|
author | Cao, Junyan Xiao, Yang Qiu, Weihong Zhang, Yanling Dou, Zulin Ren, Jie Zheng, Rongqin Zheng, Hairong Chen, Zhaocong |
author_facet | Cao, Junyan Xiao, Yang Qiu, Weihong Zhang, Yanling Dou, Zulin Ren, Jie Zheng, Rongqin Zheng, Hairong Chen, Zhaocong |
author_sort | Cao, Junyan |
collection | PubMed |
description | BACKGROUND: To explore the feasibility of corrected slack angle acquired from two-dimensional shear wave elastography (2D-SWE) for quantitating the spasticity of medial gastrocnemius (MG) in stroke patients. METHODS: Consecutive stroke patients with spastic MG and matched healthy controls were recruited. Intra- and interobserver reliability of 2D-SWE measurement were evaluated, and the correlation between corrected slack angle and modified Ashworth scale (MAS) score was examined. The corrected slack angle before and after botulinum toxin A (BoNT-A) injection was compared and its diagnostic performance in classifying the severity of spasticity were assessed with receiver operating characteristic (ROC) curve analysis. RESULTS: The intra- (0.791 95% CI 0.432–0.932) and interobserver (0.751 95% CI 0.382–0.916) reliability of slack angle acquired with 2D-SWE were good. Significant correlation was found between corrected slack angle and MAS score (R = − 0.849, p < 0.001). The corrected slack angle increased after BoNT-A injection. The cutoff value of MAS ≥ 3 had the highest sensitivity (100%) and specificity (93.33%). The positive predictive value (PPV) for classification of MAS ≥ 1+ and the negative predictive value (NPV) for classification of MAS ≥ 3 were greater than 90%. CONCLUSION: 2D-SWE was a reliable method to quantitate the post-stroke spasticity. The corrected slack angle had advantage in classifying the severity of spasticity, especially in early identification of mild spasticity and confirmation of severe spasticity. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12984-022-00995-8. |
format | Online Article Text |
id | pubmed-8817514 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-88175142022-02-07 Reliability and diagnostic accuracy of corrected slack angle derived from 2D-SWE in quantitating muscle spasticity of stroke patients Cao, Junyan Xiao, Yang Qiu, Weihong Zhang, Yanling Dou, Zulin Ren, Jie Zheng, Rongqin Zheng, Hairong Chen, Zhaocong J Neuroeng Rehabil Research BACKGROUND: To explore the feasibility of corrected slack angle acquired from two-dimensional shear wave elastography (2D-SWE) for quantitating the spasticity of medial gastrocnemius (MG) in stroke patients. METHODS: Consecutive stroke patients with spastic MG and matched healthy controls were recruited. Intra- and interobserver reliability of 2D-SWE measurement were evaluated, and the correlation between corrected slack angle and modified Ashworth scale (MAS) score was examined. The corrected slack angle before and after botulinum toxin A (BoNT-A) injection was compared and its diagnostic performance in classifying the severity of spasticity were assessed with receiver operating characteristic (ROC) curve analysis. RESULTS: The intra- (0.791 95% CI 0.432–0.932) and interobserver (0.751 95% CI 0.382–0.916) reliability of slack angle acquired with 2D-SWE were good. Significant correlation was found between corrected slack angle and MAS score (R = − 0.849, p < 0.001). The corrected slack angle increased after BoNT-A injection. The cutoff value of MAS ≥ 3 had the highest sensitivity (100%) and specificity (93.33%). The positive predictive value (PPV) for classification of MAS ≥ 1+ and the negative predictive value (NPV) for classification of MAS ≥ 3 were greater than 90%. CONCLUSION: 2D-SWE was a reliable method to quantitate the post-stroke spasticity. The corrected slack angle had advantage in classifying the severity of spasticity, especially in early identification of mild spasticity and confirmation of severe spasticity. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12984-022-00995-8. BioMed Central 2022-02-05 /pmc/articles/PMC8817514/ /pubmed/35120556 http://dx.doi.org/10.1186/s12984-022-00995-8 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Cao, Junyan Xiao, Yang Qiu, Weihong Zhang, Yanling Dou, Zulin Ren, Jie Zheng, Rongqin Zheng, Hairong Chen, Zhaocong Reliability and diagnostic accuracy of corrected slack angle derived from 2D-SWE in quantitating muscle spasticity of stroke patients |
title | Reliability and diagnostic accuracy of corrected slack angle derived from 2D-SWE in quantitating muscle spasticity of stroke patients |
title_full | Reliability and diagnostic accuracy of corrected slack angle derived from 2D-SWE in quantitating muscle spasticity of stroke patients |
title_fullStr | Reliability and diagnostic accuracy of corrected slack angle derived from 2D-SWE in quantitating muscle spasticity of stroke patients |
title_full_unstemmed | Reliability and diagnostic accuracy of corrected slack angle derived from 2D-SWE in quantitating muscle spasticity of stroke patients |
title_short | Reliability and diagnostic accuracy of corrected slack angle derived from 2D-SWE in quantitating muscle spasticity of stroke patients |
title_sort | reliability and diagnostic accuracy of corrected slack angle derived from 2d-swe in quantitating muscle spasticity of stroke patients |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8817514/ https://www.ncbi.nlm.nih.gov/pubmed/35120556 http://dx.doi.org/10.1186/s12984-022-00995-8 |
work_keys_str_mv | AT caojunyan reliabilityanddiagnosticaccuracyofcorrectedslackanglederivedfrom2dsweinquantitatingmusclespasticityofstrokepatients AT xiaoyang reliabilityanddiagnosticaccuracyofcorrectedslackanglederivedfrom2dsweinquantitatingmusclespasticityofstrokepatients AT qiuweihong reliabilityanddiagnosticaccuracyofcorrectedslackanglederivedfrom2dsweinquantitatingmusclespasticityofstrokepatients AT zhangyanling reliabilityanddiagnosticaccuracyofcorrectedslackanglederivedfrom2dsweinquantitatingmusclespasticityofstrokepatients AT douzulin reliabilityanddiagnosticaccuracyofcorrectedslackanglederivedfrom2dsweinquantitatingmusclespasticityofstrokepatients AT renjie reliabilityanddiagnosticaccuracyofcorrectedslackanglederivedfrom2dsweinquantitatingmusclespasticityofstrokepatients AT zhengrongqin reliabilityanddiagnosticaccuracyofcorrectedslackanglederivedfrom2dsweinquantitatingmusclespasticityofstrokepatients AT zhenghairong reliabilityanddiagnosticaccuracyofcorrectedslackanglederivedfrom2dsweinquantitatingmusclespasticityofstrokepatients AT chenzhaocong reliabilityanddiagnosticaccuracyofcorrectedslackanglederivedfrom2dsweinquantitatingmusclespasticityofstrokepatients |