Cargando…

Repair of a high-flow superficial femoral arteriovenous fistula using a bell-bottom iliac limb endoprosthesis

A 50-year-old patient had presented with recalcitrant right lower extremity venous stasis ulceration, atrial fibrillation, and congestive heart failure. He had a history of a gunshot wound to the right thigh >30 years previously, which had been managed without surgery. Computed tomography angiogr...

Descripción completa

Detalles Bibliográficos
Autores principales: Jhajj, Sandeep, Kar, Rahul, Teruya, Theodore H., Patel, Sheela T.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8818908/
https://www.ncbi.nlm.nih.gov/pubmed/35146218
http://dx.doi.org/10.1016/j.jvscit.2021.11.010
_version_ 1784645935799730176
author Jhajj, Sandeep
Kar, Rahul
Teruya, Theodore H.
Patel, Sheela T.
author_facet Jhajj, Sandeep
Kar, Rahul
Teruya, Theodore H.
Patel, Sheela T.
author_sort Jhajj, Sandeep
collection PubMed
description A 50-year-old patient had presented with recalcitrant right lower extremity venous stasis ulceration, atrial fibrillation, and congestive heart failure. He had a history of a gunshot wound to the right thigh >30 years previously, which had been managed without surgery. Computed tomography angiography indicated a fistulous communication between the right superficial femoral artery and vein with massively dilated right iliofemoral venous and arterial systems. He was treated with stent-graft coverage of the superficial femoral arteriovenous fistula using a bell-bottom iliac limb endoprosthesis. This stent-graft accommodated the diameter asymmetry in the superficial femoral artery caused by the long-standing fistula and ameliorated the symptoms that had afflicted him for decades.
format Online
Article
Text
id pubmed-8818908
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-88189082022-02-09 Repair of a high-flow superficial femoral arteriovenous fistula using a bell-bottom iliac limb endoprosthesis Jhajj, Sandeep Kar, Rahul Teruya, Theodore H. Patel, Sheela T. J Vasc Surg Cases Innov Tech Case report A 50-year-old patient had presented with recalcitrant right lower extremity venous stasis ulceration, atrial fibrillation, and congestive heart failure. He had a history of a gunshot wound to the right thigh >30 years previously, which had been managed without surgery. Computed tomography angiography indicated a fistulous communication between the right superficial femoral artery and vein with massively dilated right iliofemoral venous and arterial systems. He was treated with stent-graft coverage of the superficial femoral arteriovenous fistula using a bell-bottom iliac limb endoprosthesis. This stent-graft accommodated the diameter asymmetry in the superficial femoral artery caused by the long-standing fistula and ameliorated the symptoms that had afflicted him for decades. Elsevier 2022-01-05 /pmc/articles/PMC8818908/ /pubmed/35146218 http://dx.doi.org/10.1016/j.jvscit.2021.11.010 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case report
Jhajj, Sandeep
Kar, Rahul
Teruya, Theodore H.
Patel, Sheela T.
Repair of a high-flow superficial femoral arteriovenous fistula using a bell-bottom iliac limb endoprosthesis
title Repair of a high-flow superficial femoral arteriovenous fistula using a bell-bottom iliac limb endoprosthesis
title_full Repair of a high-flow superficial femoral arteriovenous fistula using a bell-bottom iliac limb endoprosthesis
title_fullStr Repair of a high-flow superficial femoral arteriovenous fistula using a bell-bottom iliac limb endoprosthesis
title_full_unstemmed Repair of a high-flow superficial femoral arteriovenous fistula using a bell-bottom iliac limb endoprosthesis
title_short Repair of a high-flow superficial femoral arteriovenous fistula using a bell-bottom iliac limb endoprosthesis
title_sort repair of a high-flow superficial femoral arteriovenous fistula using a bell-bottom iliac limb endoprosthesis
topic Case report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8818908/
https://www.ncbi.nlm.nih.gov/pubmed/35146218
http://dx.doi.org/10.1016/j.jvscit.2021.11.010
work_keys_str_mv AT jhajjsandeep repairofahighflowsuperficialfemoralarteriovenousfistulausingabellbottomiliaclimbendoprosthesis
AT karrahul repairofahighflowsuperficialfemoralarteriovenousfistulausingabellbottomiliaclimbendoprosthesis
AT teruyatheodoreh repairofahighflowsuperficialfemoralarteriovenousfistulausingabellbottomiliaclimbendoprosthesis
AT patelsheelat repairofahighflowsuperficialfemoralarteriovenousfistulausingabellbottomiliaclimbendoprosthesis