Cargando…

Hawkins wiring for three-part fractures of the proximal humerus: A case series()

Three-part proximal humerus fractures in the elderly continue to be difficult to surgically treat. We evaluated the Hawkins wiring (HW) technique, which utilizes figure-of-eight tension band wiring, to treat three-part proximal humerus fractures involving the greater tuberosity. Currently, there is...

Descripción completa

Detalles Bibliográficos
Autores principales: Lazzari, Bradley J., Yoo, Charlie J., Kamson, Anthony O., Muzio, Anna E., Lippe, Ronald W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8819121/
https://www.ncbi.nlm.nih.gov/pubmed/35146108
http://dx.doi.org/10.1016/j.tcr.2022.100614
_version_ 1784645986670346240
author Lazzari, Bradley J.
Yoo, Charlie J.
Kamson, Anthony O.
Muzio, Anna E.
Lippe, Ronald W.
author_facet Lazzari, Bradley J.
Yoo, Charlie J.
Kamson, Anthony O.
Muzio, Anna E.
Lippe, Ronald W.
author_sort Lazzari, Bradley J.
collection PubMed
description Three-part proximal humerus fractures in the elderly continue to be difficult to surgically treat. We evaluated the Hawkins wiring (HW) technique, which utilizes figure-of-eight tension band wiring, to treat three-part proximal humerus fractures involving the greater tuberosity. Currently, there is a paucity of data detailing patient outcomes and radiographic follow-up of this technique. The purpose of this case series is to evaluate patient reported outcomes and radiographic follow-up for fractures treated with this technique. Over two years, six patients at our institution underwent HW to treat three-part proximal humerus fractures. Average DASH and Oxford Shoulder scores (OSS) were 20.4 (range, 1–40) and 40 (range, 33–46) respectively. All patients had satisfactory return of function after surgery. Radiographic union was achieved in all six patients and there were no reported complications. HW technique is an efficacious treatment for three-part proximal humerus fractures in elderly patients.
format Online
Article
Text
id pubmed-8819121
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-88191212022-02-09 Hawkins wiring for three-part fractures of the proximal humerus: A case series() Lazzari, Bradley J. Yoo, Charlie J. Kamson, Anthony O. Muzio, Anna E. Lippe, Ronald W. Trauma Case Rep Case Report Three-part proximal humerus fractures in the elderly continue to be difficult to surgically treat. We evaluated the Hawkins wiring (HW) technique, which utilizes figure-of-eight tension band wiring, to treat three-part proximal humerus fractures involving the greater tuberosity. Currently, there is a paucity of data detailing patient outcomes and radiographic follow-up of this technique. The purpose of this case series is to evaluate patient reported outcomes and radiographic follow-up for fractures treated with this technique. Over two years, six patients at our institution underwent HW to treat three-part proximal humerus fractures. Average DASH and Oxford Shoulder scores (OSS) were 20.4 (range, 1–40) and 40 (range, 33–46) respectively. All patients had satisfactory return of function after surgery. Radiographic union was achieved in all six patients and there were no reported complications. HW technique is an efficacious treatment for three-part proximal humerus fractures in elderly patients. Elsevier 2022-01-26 /pmc/articles/PMC8819121/ /pubmed/35146108 http://dx.doi.org/10.1016/j.tcr.2022.100614 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Lazzari, Bradley J.
Yoo, Charlie J.
Kamson, Anthony O.
Muzio, Anna E.
Lippe, Ronald W.
Hawkins wiring for three-part fractures of the proximal humerus: A case series()
title Hawkins wiring for three-part fractures of the proximal humerus: A case series()
title_full Hawkins wiring for three-part fractures of the proximal humerus: A case series()
title_fullStr Hawkins wiring for three-part fractures of the proximal humerus: A case series()
title_full_unstemmed Hawkins wiring for three-part fractures of the proximal humerus: A case series()
title_short Hawkins wiring for three-part fractures of the proximal humerus: A case series()
title_sort hawkins wiring for three-part fractures of the proximal humerus: a case series()
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8819121/
https://www.ncbi.nlm.nih.gov/pubmed/35146108
http://dx.doi.org/10.1016/j.tcr.2022.100614
work_keys_str_mv AT lazzaribradleyj hawkinswiringforthreepartfracturesoftheproximalhumerusacaseseries
AT yoocharliej hawkinswiringforthreepartfracturesoftheproximalhumerusacaseseries
AT kamsonanthonyo hawkinswiringforthreepartfracturesoftheproximalhumerusacaseseries
AT muzioannae hawkinswiringforthreepartfracturesoftheproximalhumerusacaseseries
AT lipperonaldw hawkinswiringforthreepartfracturesoftheproximalhumerusacaseseries