Cargando…

Comparison of multiphase data from CT perfusion vs clinical 4-phase CT scans with respect to image quality, lesion detection, and LI-RADS classification in HCC patients

PURPOSE: The aim of this study was to assess the image quality and diagnostic performance of reconstructed arterial (A) and portal venous (PV) phases in computed tomography perfusion (CTP) scans compared to the corresponding phases in standard 4-phase CT and to assess the utility for LI-RADS classif...

Descripción completa

Detalles Bibliográficos
Autores principales: Mohammadi, A., Bartholmae, W., Woisetschläger, M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8819526/
https://www.ncbi.nlm.nih.gov/pubmed/35146150
http://dx.doi.org/10.1016/j.heliyon.2022.e08757
_version_ 1784646077738123264
author Mohammadi, A.
Bartholmae, W.
Woisetschläger, M.
author_facet Mohammadi, A.
Bartholmae, W.
Woisetschläger, M.
author_sort Mohammadi, A.
collection PubMed
description PURPOSE: The aim of this study was to assess the image quality and diagnostic performance of reconstructed arterial (A) and portal venous (PV) phases in computed tomography perfusion (CTP) scans compared to the corresponding phases in standard 4-phase CT and to assess the utility for LI-RADS classification using CTP and 4-phase 4CT. METHODS: A total of 26 scans with each method (CTP and 4-phase CT) from 19 hepatocellular carcinoma patients were analyzed and compared. Arterial and PV phases reconstructed by advanced modeled iterative reconstruction at strength 4 (ADMIRE 4) from raw CTP data were compared with image sets from arterial and PV phases of 4-phase CT (ADMIRE 3) in the same patient with respect to image quality. RESULTS: Quantitative image analysis showed that reconstructed CTP datasets were equivalent to 4-phase CT image sets. Qualitative image analysis revealed similar lesion detection rates with the 2 methods for patients with an abdominal diameter ≤36 cm and body weight <90 kg, but lower detection rates with CTP for patients with an abdominal diameter >37 cm. There was no difference in Liver Imaging Reporting and Data System (LI-RADS) classifications between the 2 methods. CONCLUSION: Reconstructed CTP images can potentially replace 4-phase CT images in patients weighing <90 kg and with a body diameter <37 cm, as the 2 methods are comparable in terms of quantitative image quality and ability to detect and classify lesions based on LI-RADS criteria.
format Online
Article
Text
id pubmed-8819526
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-88195262022-02-09 Comparison of multiphase data from CT perfusion vs clinical 4-phase CT scans with respect to image quality, lesion detection, and LI-RADS classification in HCC patients Mohammadi, A. Bartholmae, W. Woisetschläger, M. Heliyon Research Article PURPOSE: The aim of this study was to assess the image quality and diagnostic performance of reconstructed arterial (A) and portal venous (PV) phases in computed tomography perfusion (CTP) scans compared to the corresponding phases in standard 4-phase CT and to assess the utility for LI-RADS classification using CTP and 4-phase 4CT. METHODS: A total of 26 scans with each method (CTP and 4-phase CT) from 19 hepatocellular carcinoma patients were analyzed and compared. Arterial and PV phases reconstructed by advanced modeled iterative reconstruction at strength 4 (ADMIRE 4) from raw CTP data were compared with image sets from arterial and PV phases of 4-phase CT (ADMIRE 3) in the same patient with respect to image quality. RESULTS: Quantitative image analysis showed that reconstructed CTP datasets were equivalent to 4-phase CT image sets. Qualitative image analysis revealed similar lesion detection rates with the 2 methods for patients with an abdominal diameter ≤36 cm and body weight <90 kg, but lower detection rates with CTP for patients with an abdominal diameter >37 cm. There was no difference in Liver Imaging Reporting and Data System (LI-RADS) classifications between the 2 methods. CONCLUSION: Reconstructed CTP images can potentially replace 4-phase CT images in patients weighing <90 kg and with a body diameter <37 cm, as the 2 methods are comparable in terms of quantitative image quality and ability to detect and classify lesions based on LI-RADS criteria. Elsevier 2022-01-13 /pmc/articles/PMC8819526/ /pubmed/35146150 http://dx.doi.org/10.1016/j.heliyon.2022.e08757 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Research Article
Mohammadi, A.
Bartholmae, W.
Woisetschläger, M.
Comparison of multiphase data from CT perfusion vs clinical 4-phase CT scans with respect to image quality, lesion detection, and LI-RADS classification in HCC patients
title Comparison of multiphase data from CT perfusion vs clinical 4-phase CT scans with respect to image quality, lesion detection, and LI-RADS classification in HCC patients
title_full Comparison of multiphase data from CT perfusion vs clinical 4-phase CT scans with respect to image quality, lesion detection, and LI-RADS classification in HCC patients
title_fullStr Comparison of multiphase data from CT perfusion vs clinical 4-phase CT scans with respect to image quality, lesion detection, and LI-RADS classification in HCC patients
title_full_unstemmed Comparison of multiphase data from CT perfusion vs clinical 4-phase CT scans with respect to image quality, lesion detection, and LI-RADS classification in HCC patients
title_short Comparison of multiphase data from CT perfusion vs clinical 4-phase CT scans with respect to image quality, lesion detection, and LI-RADS classification in HCC patients
title_sort comparison of multiphase data from ct perfusion vs clinical 4-phase ct scans with respect to image quality, lesion detection, and li-rads classification in hcc patients
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8819526/
https://www.ncbi.nlm.nih.gov/pubmed/35146150
http://dx.doi.org/10.1016/j.heliyon.2022.e08757
work_keys_str_mv AT mohammadia comparisonofmultiphasedatafromctperfusionvsclinical4phasectscanswithrespecttoimagequalitylesiondetectionandliradsclassificationinhccpatients
AT bartholmaew comparisonofmultiphasedatafromctperfusionvsclinical4phasectscanswithrespecttoimagequalitylesiondetectionandliradsclassificationinhccpatients
AT woisetschlagerm comparisonofmultiphasedatafromctperfusionvsclinical4phasectscanswithrespecttoimagequalitylesiondetectionandliradsclassificationinhccpatients