Cargando…

A study of screw placement to obtain the optimal pull-out resistance of lumbar pedicle screws—analysis of Hounsfield units measurements based on computed tomography

OBJECTIVE: The screw path of lumbar pedicle screws in the vertebral body has certain variability. It is not clear whether the screw paths in different directions can obtain the same pull-out resistance. This study intends to use CT (Computed Tomography) to measure the Hounsfield unit (HU value) arou...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Dachuan, Sun, Chi, Jiang, Jianyuan, Lu, Feizhou, Xia, Xinlei, Wang, Hongli, Zou, Fei, Ma, Xiaosheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8819881/
https://www.ncbi.nlm.nih.gov/pubmed/35130888
http://dx.doi.org/10.1186/s12891-022-05074-6
_version_ 1784646140113715200
author Li, Dachuan
Sun, Chi
Jiang, Jianyuan
Lu, Feizhou
Xia, Xinlei
Wang, Hongli
Zou, Fei
Ma, Xiaosheng
author_facet Li, Dachuan
Sun, Chi
Jiang, Jianyuan
Lu, Feizhou
Xia, Xinlei
Wang, Hongli
Zou, Fei
Ma, Xiaosheng
author_sort Li, Dachuan
collection PubMed
description OBJECTIVE: The screw path of lumbar pedicle screws in the vertebral body has certain variability. It is not clear whether the screw paths in different directions can obtain the same pull-out resistance. This study intends to use CT (Computed Tomography) to measure the Hounsfield unit (HU value) around the screw paths in different parts of the lumbar vertebral body to obtain the bone mineral density value of the corresponding parts which will provide some reference for the direction of lumbar pedicle screw placement. METHODS: This retrospective study included 200 patients with lumbar degenerative diseases selected randomly from the case base and the patient’s basic information was recorded. L1-L5 vertebral body was divided equally into the upper, middle and lower 1/3, which was consistent with the three sagittal entry directions of the pedicle screw head tilt, parallel endplate and caudal tilt, and the HU values were measured by CT cross-sectional scanning to indirectly reflect the local bone density values. The paired t-test (randomized block experiment) was used to compare the HU values of the upper, middle and lower 1 / 3 parts, with P < 0.05 being considered statistically significant. RESULTS: Comparison of HU values in different parts of each vertebral body revealed that HU values in the middle 1/3 of the L1,L2 (163.88 ± 58.44 and 152.94 ± 59.45) and in the lower 1/3 of the L4 (149.86 ± 60.18) were higher than in the other two parts of the vertebral body of the same segment(P < 0.0001,P = 0.0069 and P = 0.0024, respectively); According to the results of each stratification, patients with younger age and better bone condition had higher HU values in the middle 1/3 of L1 and L2, and higher HU values in the lower 1/3 of L3, L4 and L5; With the increase of age, the decrease of bone condition and the difference of HU value in each vertebral body gradually decreased. CONCLUSION: Although further follow-up studies are needed, based on the analysis of the statistical results, we speculate that from the perspective of obtaining the best pull-out resistance of the lumbar pedicle screws, the placement direction of L1 and L2 in the sagittal position may be as parallel to the endplate as possible; L3, L4, and L5 may be as appropriate as possible to the tail tilt theoretically.
format Online
Article
Text
id pubmed-8819881
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-88198812022-02-08 A study of screw placement to obtain the optimal pull-out resistance of lumbar pedicle screws—analysis of Hounsfield units measurements based on computed tomography Li, Dachuan Sun, Chi Jiang, Jianyuan Lu, Feizhou Xia, Xinlei Wang, Hongli Zou, Fei Ma, Xiaosheng BMC Musculoskelet Disord Research OBJECTIVE: The screw path of lumbar pedicle screws in the vertebral body has certain variability. It is not clear whether the screw paths in different directions can obtain the same pull-out resistance. This study intends to use CT (Computed Tomography) to measure the Hounsfield unit (HU value) around the screw paths in different parts of the lumbar vertebral body to obtain the bone mineral density value of the corresponding parts which will provide some reference for the direction of lumbar pedicle screw placement. METHODS: This retrospective study included 200 patients with lumbar degenerative diseases selected randomly from the case base and the patient’s basic information was recorded. L1-L5 vertebral body was divided equally into the upper, middle and lower 1/3, which was consistent with the three sagittal entry directions of the pedicle screw head tilt, parallel endplate and caudal tilt, and the HU values were measured by CT cross-sectional scanning to indirectly reflect the local bone density values. The paired t-test (randomized block experiment) was used to compare the HU values of the upper, middle and lower 1 / 3 parts, with P < 0.05 being considered statistically significant. RESULTS: Comparison of HU values in different parts of each vertebral body revealed that HU values in the middle 1/3 of the L1,L2 (163.88 ± 58.44 and 152.94 ± 59.45) and in the lower 1/3 of the L4 (149.86 ± 60.18) were higher than in the other two parts of the vertebral body of the same segment(P < 0.0001,P = 0.0069 and P = 0.0024, respectively); According to the results of each stratification, patients with younger age and better bone condition had higher HU values in the middle 1/3 of L1 and L2, and higher HU values in the lower 1/3 of L3, L4 and L5; With the increase of age, the decrease of bone condition and the difference of HU value in each vertebral body gradually decreased. CONCLUSION: Although further follow-up studies are needed, based on the analysis of the statistical results, we speculate that from the perspective of obtaining the best pull-out resistance of the lumbar pedicle screws, the placement direction of L1 and L2 in the sagittal position may be as parallel to the endplate as possible; L3, L4, and L5 may be as appropriate as possible to the tail tilt theoretically. BioMed Central 2022-02-07 /pmc/articles/PMC8819881/ /pubmed/35130888 http://dx.doi.org/10.1186/s12891-022-05074-6 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Li, Dachuan
Sun, Chi
Jiang, Jianyuan
Lu, Feizhou
Xia, Xinlei
Wang, Hongli
Zou, Fei
Ma, Xiaosheng
A study of screw placement to obtain the optimal pull-out resistance of lumbar pedicle screws—analysis of Hounsfield units measurements based on computed tomography
title A study of screw placement to obtain the optimal pull-out resistance of lumbar pedicle screws—analysis of Hounsfield units measurements based on computed tomography
title_full A study of screw placement to obtain the optimal pull-out resistance of lumbar pedicle screws—analysis of Hounsfield units measurements based on computed tomography
title_fullStr A study of screw placement to obtain the optimal pull-out resistance of lumbar pedicle screws—analysis of Hounsfield units measurements based on computed tomography
title_full_unstemmed A study of screw placement to obtain the optimal pull-out resistance of lumbar pedicle screws—analysis of Hounsfield units measurements based on computed tomography
title_short A study of screw placement to obtain the optimal pull-out resistance of lumbar pedicle screws—analysis of Hounsfield units measurements based on computed tomography
title_sort study of screw placement to obtain the optimal pull-out resistance of lumbar pedicle screws—analysis of hounsfield units measurements based on computed tomography
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8819881/
https://www.ncbi.nlm.nih.gov/pubmed/35130888
http://dx.doi.org/10.1186/s12891-022-05074-6
work_keys_str_mv AT lidachuan astudyofscrewplacementtoobtaintheoptimalpulloutresistanceoflumbarpediclescrewsanalysisofhounsfieldunitsmeasurementsbasedoncomputedtomography
AT sunchi astudyofscrewplacementtoobtaintheoptimalpulloutresistanceoflumbarpediclescrewsanalysisofhounsfieldunitsmeasurementsbasedoncomputedtomography
AT jiangjianyuan astudyofscrewplacementtoobtaintheoptimalpulloutresistanceoflumbarpediclescrewsanalysisofhounsfieldunitsmeasurementsbasedoncomputedtomography
AT lufeizhou astudyofscrewplacementtoobtaintheoptimalpulloutresistanceoflumbarpediclescrewsanalysisofhounsfieldunitsmeasurementsbasedoncomputedtomography
AT xiaxinlei astudyofscrewplacementtoobtaintheoptimalpulloutresistanceoflumbarpediclescrewsanalysisofhounsfieldunitsmeasurementsbasedoncomputedtomography
AT wanghongli astudyofscrewplacementtoobtaintheoptimalpulloutresistanceoflumbarpediclescrewsanalysisofhounsfieldunitsmeasurementsbasedoncomputedtomography
AT zoufei astudyofscrewplacementtoobtaintheoptimalpulloutresistanceoflumbarpediclescrewsanalysisofhounsfieldunitsmeasurementsbasedoncomputedtomography
AT maxiaosheng astudyofscrewplacementtoobtaintheoptimalpulloutresistanceoflumbarpediclescrewsanalysisofhounsfieldunitsmeasurementsbasedoncomputedtomography
AT lidachuan studyofscrewplacementtoobtaintheoptimalpulloutresistanceoflumbarpediclescrewsanalysisofhounsfieldunitsmeasurementsbasedoncomputedtomography
AT sunchi studyofscrewplacementtoobtaintheoptimalpulloutresistanceoflumbarpediclescrewsanalysisofhounsfieldunitsmeasurementsbasedoncomputedtomography
AT jiangjianyuan studyofscrewplacementtoobtaintheoptimalpulloutresistanceoflumbarpediclescrewsanalysisofhounsfieldunitsmeasurementsbasedoncomputedtomography
AT lufeizhou studyofscrewplacementtoobtaintheoptimalpulloutresistanceoflumbarpediclescrewsanalysisofhounsfieldunitsmeasurementsbasedoncomputedtomography
AT xiaxinlei studyofscrewplacementtoobtaintheoptimalpulloutresistanceoflumbarpediclescrewsanalysisofhounsfieldunitsmeasurementsbasedoncomputedtomography
AT wanghongli studyofscrewplacementtoobtaintheoptimalpulloutresistanceoflumbarpediclescrewsanalysisofhounsfieldunitsmeasurementsbasedoncomputedtomography
AT zoufei studyofscrewplacementtoobtaintheoptimalpulloutresistanceoflumbarpediclescrewsanalysisofhounsfieldunitsmeasurementsbasedoncomputedtomography
AT maxiaosheng studyofscrewplacementtoobtaintheoptimalpulloutresistanceoflumbarpediclescrewsanalysisofhounsfieldunitsmeasurementsbasedoncomputedtomography