Cargando…
A numerical evaluation of a novel recovery fresh air heat pump concept for a generic electric bus
Since the outbreak of the worldwide COVID-19 pandemic, public transportation networks have faced unprecedented challenges and have looked for practical solutions to address the rising safety concerns. It is deemed that in confined spaces, operating heating units (and cooling) in non-re-circulation m...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Published by Elsevier Ltd.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8820066/ https://www.ncbi.nlm.nih.gov/pubmed/35153534 http://dx.doi.org/10.1016/j.applthermaleng.2022.118181 |
_version_ | 1784646170094600192 |
---|---|
author | Afrasiabian, Ehsan Douglas, Roy Geron, Marco Cunningham, Gareth |
author_facet | Afrasiabian, Ehsan Douglas, Roy Geron, Marco Cunningham, Gareth |
author_sort | Afrasiabian, Ehsan |
collection | PubMed |
description | Since the outbreak of the worldwide COVID-19 pandemic, public transportation networks have faced unprecedented challenges and have looked for practical solutions to address the rising safety concerns. It is deemed that in confined spaces, operating heating units (and cooling) in non-re-circulation mode (i. e., all-fresh air mode) could reduce the airborne transmission of this infectious disease, by reducing the density of the pathogen and exposure time. However, this will expectedly increase the energy demand and reduce the driving range of electric buses. To tackle both the airborne transmission and energy efficiency issues, in this paper a novel recovery heat pump concept, operating in all-fresh air mode, was proposed. The novelty of this concept lies in its potential to be applied to already manufactured/in-service heat pump units as it does not require any additional components or need for redesigning the heating systems. In this concept, the cabin exhaust air is directed to pass through the evaporator of the heat pump system to recover part of the waste heat from the cabin and to improve the efficiency of the system. In this paper, a 0D/1D coupled model of a generic single-deck cabin and a heat pump system was developed in the Simulink environment of MATLAB (R2020b) software. The model was run in two different modes, namely the all-fresh air (as a baseline and a recovery heat pump concepts), and the air re-circulation mode (as a conventional heat pump concept with a 50% re-circulation ratio). The performance of these concepts was investigated to evaluate how an all-fresh air policy could affect the performance of the system, as well as the energy-saving potential of the proposed recovery concept. The performance of the system was studied under different ambient temperatures of −5 °C, 0 °C, and 5 °C, and for low and moderate occupancy levels. Results show that implementing the all-fresh air policy in the recovery and baseline concepts significantly improved the ventilation rate per person by at least 102% and at most 125%, compared to the air-re-circulating heat pump. Moreover, adopting the recovery concept reduced the power demand by at least 8% and at most 11%, compared to the baseline all-fresh air heat pump, for the selected fan and blower flow rates. The presented results in this paper along with the applicability of this concept to in-service mobile heat pumps could make it a feasible, practical, and quick trade-off solution to help the bus operators to protect people and improve the energy efficiency of their service. |
format | Online Article Text |
id | pubmed-8820066 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Published by Elsevier Ltd. |
record_format | MEDLINE/PubMed |
spelling | pubmed-88200662022-02-08 A numerical evaluation of a novel recovery fresh air heat pump concept for a generic electric bus Afrasiabian, Ehsan Douglas, Roy Geron, Marco Cunningham, Gareth Appl Therm Eng Article Since the outbreak of the worldwide COVID-19 pandemic, public transportation networks have faced unprecedented challenges and have looked for practical solutions to address the rising safety concerns. It is deemed that in confined spaces, operating heating units (and cooling) in non-re-circulation mode (i. e., all-fresh air mode) could reduce the airborne transmission of this infectious disease, by reducing the density of the pathogen and exposure time. However, this will expectedly increase the energy demand and reduce the driving range of electric buses. To tackle both the airborne transmission and energy efficiency issues, in this paper a novel recovery heat pump concept, operating in all-fresh air mode, was proposed. The novelty of this concept lies in its potential to be applied to already manufactured/in-service heat pump units as it does not require any additional components or need for redesigning the heating systems. In this concept, the cabin exhaust air is directed to pass through the evaporator of the heat pump system to recover part of the waste heat from the cabin and to improve the efficiency of the system. In this paper, a 0D/1D coupled model of a generic single-deck cabin and a heat pump system was developed in the Simulink environment of MATLAB (R2020b) software. The model was run in two different modes, namely the all-fresh air (as a baseline and a recovery heat pump concepts), and the air re-circulation mode (as a conventional heat pump concept with a 50% re-circulation ratio). The performance of these concepts was investigated to evaluate how an all-fresh air policy could affect the performance of the system, as well as the energy-saving potential of the proposed recovery concept. The performance of the system was studied under different ambient temperatures of −5 °C, 0 °C, and 5 °C, and for low and moderate occupancy levels. Results show that implementing the all-fresh air policy in the recovery and baseline concepts significantly improved the ventilation rate per person by at least 102% and at most 125%, compared to the air-re-circulating heat pump. Moreover, adopting the recovery concept reduced the power demand by at least 8% and at most 11%, compared to the baseline all-fresh air heat pump, for the selected fan and blower flow rates. The presented results in this paper along with the applicability of this concept to in-service mobile heat pumps could make it a feasible, practical, and quick trade-off solution to help the bus operators to protect people and improve the energy efficiency of their service. Published by Elsevier Ltd. 2022-06-05 2022-02-07 /pmc/articles/PMC8820066/ /pubmed/35153534 http://dx.doi.org/10.1016/j.applthermaleng.2022.118181 Text en Crown Copyright © 2022 Published by Elsevier Ltd. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active. |
spellingShingle | Article Afrasiabian, Ehsan Douglas, Roy Geron, Marco Cunningham, Gareth A numerical evaluation of a novel recovery fresh air heat pump concept for a generic electric bus |
title | A numerical evaluation of a novel recovery fresh air heat pump concept for a generic electric bus |
title_full | A numerical evaluation of a novel recovery fresh air heat pump concept for a generic electric bus |
title_fullStr | A numerical evaluation of a novel recovery fresh air heat pump concept for a generic electric bus |
title_full_unstemmed | A numerical evaluation of a novel recovery fresh air heat pump concept for a generic electric bus |
title_short | A numerical evaluation of a novel recovery fresh air heat pump concept for a generic electric bus |
title_sort | numerical evaluation of a novel recovery fresh air heat pump concept for a generic electric bus |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8820066/ https://www.ncbi.nlm.nih.gov/pubmed/35153534 http://dx.doi.org/10.1016/j.applthermaleng.2022.118181 |
work_keys_str_mv | AT afrasiabianehsan anumericalevaluationofanovelrecoveryfreshairheatpumpconceptforagenericelectricbus AT douglasroy anumericalevaluationofanovelrecoveryfreshairheatpumpconceptforagenericelectricbus AT geronmarco anumericalevaluationofanovelrecoveryfreshairheatpumpconceptforagenericelectricbus AT cunninghamgareth anumericalevaluationofanovelrecoveryfreshairheatpumpconceptforagenericelectricbus AT afrasiabianehsan numericalevaluationofanovelrecoveryfreshairheatpumpconceptforagenericelectricbus AT douglasroy numericalevaluationofanovelrecoveryfreshairheatpumpconceptforagenericelectricbus AT geronmarco numericalevaluationofanovelrecoveryfreshairheatpumpconceptforagenericelectricbus AT cunninghamgareth numericalevaluationofanovelrecoveryfreshairheatpumpconceptforagenericelectricbus |