Cargando…

Simultaneous pure T(2) and varying T(2)′-weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses

Spin-echo (SE) BOLD fMRI has high microvascular specificity, and thus provides a more reliable means to localize neural activity compared to conventional gradient-echo BOLD fMRI. However, the most common SE BOLD acquisition method, SE-EPI, is known to suffer from T(2)′ contrast contamination with un...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Fuyixue, Dong, Zijing, Wald, Lawrence L., Polimeni, Jonathan R., Setsompop, Kawin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8820652/
https://www.ncbi.nlm.nih.gov/pubmed/34655771
http://dx.doi.org/10.1016/j.neuroimage.2021.118641
_version_ 1784646249309274112
author Wang, Fuyixue
Dong, Zijing
Wald, Lawrence L.
Polimeni, Jonathan R.
Setsompop, Kawin
author_facet Wang, Fuyixue
Dong, Zijing
Wald, Lawrence L.
Polimeni, Jonathan R.
Setsompop, Kawin
author_sort Wang, Fuyixue
collection PubMed
description Spin-echo (SE) BOLD fMRI has high microvascular specificity, and thus provides a more reliable means to localize neural activity compared to conventional gradient-echo BOLD fMRI. However, the most common SE BOLD acquisition method, SE-EPI, is known to suffer from T(2)′ contrast contamination with undesirable draining vein bias. To address this, in this study, we extended a recently developed distortion/blurring-free multi-shot EPI technique, Echo-Planar Time-resolved Imaging (EPTI), to cortical-depth dependent SE-fMRI at 7T to test whether it could provide purer SE BOLD contrast with minimal T(2)′ contamination for improved neuronal specificity. From the same acquisition, the time-resolved feature of EPTI also provides a series of asymmetric SE (ASE) images with varying T(2)′ weightings, and enables extraction of data equivalent to conventional SE EPI with different echo train lengths (ETLs). This allows us to systematically examine how T(2)′-contribution affects different SE acquisition strategies using a single dataset. A low-rank spatiotemporal subspace reconstruction was implemented for the SE-EPTI acquisition, which incorporates corrections for both shot-to-shot phase variations and dynamic B(0) drifts. SE-EPTI was used in a visual task fMRI experiment to demonstrate that i) the pure SE image provided by EPTI results in the highest microvascular specificity; ii) the ASE EPTI series, with a graded introduction of T(2)′ weightings at time points farther away from the pure SE, show a gradual sensitivity increase along with increasing draining vein bias; iii) the longer ETL seen in conventional SE EPI acquisitions will induce more draining vein bias. Consistent results were observed across multiple subjects, demonstrating the robustness of the proposed technique for SE-BOLD fMRI with high specificity.
format Online
Article
Text
id pubmed-8820652
institution National Center for Biotechnology Information
language English
publishDate 2021
record_format MEDLINE/PubMed
spelling pubmed-88206522022-02-07 Simultaneous pure T(2) and varying T(2)′-weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses Wang, Fuyixue Dong, Zijing Wald, Lawrence L. Polimeni, Jonathan R. Setsompop, Kawin Neuroimage Article Spin-echo (SE) BOLD fMRI has high microvascular specificity, and thus provides a more reliable means to localize neural activity compared to conventional gradient-echo BOLD fMRI. However, the most common SE BOLD acquisition method, SE-EPI, is known to suffer from T(2)′ contrast contamination with undesirable draining vein bias. To address this, in this study, we extended a recently developed distortion/blurring-free multi-shot EPI technique, Echo-Planar Time-resolved Imaging (EPTI), to cortical-depth dependent SE-fMRI at 7T to test whether it could provide purer SE BOLD contrast with minimal T(2)′ contamination for improved neuronal specificity. From the same acquisition, the time-resolved feature of EPTI also provides a series of asymmetric SE (ASE) images with varying T(2)′ weightings, and enables extraction of data equivalent to conventional SE EPI with different echo train lengths (ETLs). This allows us to systematically examine how T(2)′-contribution affects different SE acquisition strategies using a single dataset. A low-rank spatiotemporal subspace reconstruction was implemented for the SE-EPTI acquisition, which incorporates corrections for both shot-to-shot phase variations and dynamic B(0) drifts. SE-EPTI was used in a visual task fMRI experiment to demonstrate that i) the pure SE image provided by EPTI results in the highest microvascular specificity; ii) the ASE EPTI series, with a graded introduction of T(2)′ weightings at time points farther away from the pure SE, show a gradual sensitivity increase along with increasing draining vein bias; iii) the longer ETL seen in conventional SE EPI acquisitions will induce more draining vein bias. Consistent results were observed across multiple subjects, demonstrating the robustness of the proposed technique for SE-BOLD fMRI with high specificity. 2021-12-15 2021-10-13 /pmc/articles/PMC8820652/ /pubmed/34655771 http://dx.doi.org/10.1016/j.neuroimage.2021.118641 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license
spellingShingle Article
Wang, Fuyixue
Dong, Zijing
Wald, Lawrence L.
Polimeni, Jonathan R.
Setsompop, Kawin
Simultaneous pure T(2) and varying T(2)′-weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses
title Simultaneous pure T(2) and varying T(2)′-weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses
title_full Simultaneous pure T(2) and varying T(2)′-weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses
title_fullStr Simultaneous pure T(2) and varying T(2)′-weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses
title_full_unstemmed Simultaneous pure T(2) and varying T(2)′-weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses
title_short Simultaneous pure T(2) and varying T(2)′-weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses
title_sort simultaneous pure t(2) and varying t(2)′-weighted bold fmri using echo planar time-resolved imaging for mapping cortical-depth dependent responses
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8820652/
https://www.ncbi.nlm.nih.gov/pubmed/34655771
http://dx.doi.org/10.1016/j.neuroimage.2021.118641
work_keys_str_mv AT wangfuyixue simultaneouspuret2andvaryingt2weightedboldfmriusingechoplanartimeresolvedimagingformappingcorticaldepthdependentresponses
AT dongzijing simultaneouspuret2andvaryingt2weightedboldfmriusingechoplanartimeresolvedimagingformappingcorticaldepthdependentresponses
AT waldlawrencel simultaneouspuret2andvaryingt2weightedboldfmriusingechoplanartimeresolvedimagingformappingcorticaldepthdependentresponses
AT polimenijonathanr simultaneouspuret2andvaryingt2weightedboldfmriusingechoplanartimeresolvedimagingformappingcorticaldepthdependentresponses
AT setsompopkawin simultaneouspuret2andvaryingt2weightedboldfmriusingechoplanartimeresolvedimagingformappingcorticaldepthdependentresponses