Simultaneous pure T(2) and varying T(2)′-weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses
Spin-echo (SE) BOLD fMRI has high microvascular specificity, and thus provides a more reliable means to localize neural activity compared to conventional gradient-echo BOLD fMRI. However, the most common SE BOLD acquisition method, SE-EPI, is known to suffer from T(2)′ contrast contamination with un...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8820652/ https://www.ncbi.nlm.nih.gov/pubmed/34655771 http://dx.doi.org/10.1016/j.neuroimage.2021.118641 |
_version_ | 1784646249309274112 |
---|---|
author | Wang, Fuyixue Dong, Zijing Wald, Lawrence L. Polimeni, Jonathan R. Setsompop, Kawin |
author_facet | Wang, Fuyixue Dong, Zijing Wald, Lawrence L. Polimeni, Jonathan R. Setsompop, Kawin |
author_sort | Wang, Fuyixue |
collection | PubMed |
description | Spin-echo (SE) BOLD fMRI has high microvascular specificity, and thus provides a more reliable means to localize neural activity compared to conventional gradient-echo BOLD fMRI. However, the most common SE BOLD acquisition method, SE-EPI, is known to suffer from T(2)′ contrast contamination with undesirable draining vein bias. To address this, in this study, we extended a recently developed distortion/blurring-free multi-shot EPI technique, Echo-Planar Time-resolved Imaging (EPTI), to cortical-depth dependent SE-fMRI at 7T to test whether it could provide purer SE BOLD contrast with minimal T(2)′ contamination for improved neuronal specificity. From the same acquisition, the time-resolved feature of EPTI also provides a series of asymmetric SE (ASE) images with varying T(2)′ weightings, and enables extraction of data equivalent to conventional SE EPI with different echo train lengths (ETLs). This allows us to systematically examine how T(2)′-contribution affects different SE acquisition strategies using a single dataset. A low-rank spatiotemporal subspace reconstruction was implemented for the SE-EPTI acquisition, which incorporates corrections for both shot-to-shot phase variations and dynamic B(0) drifts. SE-EPTI was used in a visual task fMRI experiment to demonstrate that i) the pure SE image provided by EPTI results in the highest microvascular specificity; ii) the ASE EPTI series, with a graded introduction of T(2)′ weightings at time points farther away from the pure SE, show a gradual sensitivity increase along with increasing draining vein bias; iii) the longer ETL seen in conventional SE EPI acquisitions will induce more draining vein bias. Consistent results were observed across multiple subjects, demonstrating the robustness of the proposed technique for SE-BOLD fMRI with high specificity. |
format | Online Article Text |
id | pubmed-8820652 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
record_format | MEDLINE/PubMed |
spelling | pubmed-88206522022-02-07 Simultaneous pure T(2) and varying T(2)′-weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses Wang, Fuyixue Dong, Zijing Wald, Lawrence L. Polimeni, Jonathan R. Setsompop, Kawin Neuroimage Article Spin-echo (SE) BOLD fMRI has high microvascular specificity, and thus provides a more reliable means to localize neural activity compared to conventional gradient-echo BOLD fMRI. However, the most common SE BOLD acquisition method, SE-EPI, is known to suffer from T(2)′ contrast contamination with undesirable draining vein bias. To address this, in this study, we extended a recently developed distortion/blurring-free multi-shot EPI technique, Echo-Planar Time-resolved Imaging (EPTI), to cortical-depth dependent SE-fMRI at 7T to test whether it could provide purer SE BOLD contrast with minimal T(2)′ contamination for improved neuronal specificity. From the same acquisition, the time-resolved feature of EPTI also provides a series of asymmetric SE (ASE) images with varying T(2)′ weightings, and enables extraction of data equivalent to conventional SE EPI with different echo train lengths (ETLs). This allows us to systematically examine how T(2)′-contribution affects different SE acquisition strategies using a single dataset. A low-rank spatiotemporal subspace reconstruction was implemented for the SE-EPTI acquisition, which incorporates corrections for both shot-to-shot phase variations and dynamic B(0) drifts. SE-EPTI was used in a visual task fMRI experiment to demonstrate that i) the pure SE image provided by EPTI results in the highest microvascular specificity; ii) the ASE EPTI series, with a graded introduction of T(2)′ weightings at time points farther away from the pure SE, show a gradual sensitivity increase along with increasing draining vein bias; iii) the longer ETL seen in conventional SE EPI acquisitions will induce more draining vein bias. Consistent results were observed across multiple subjects, demonstrating the robustness of the proposed technique for SE-BOLD fMRI with high specificity. 2021-12-15 2021-10-13 /pmc/articles/PMC8820652/ /pubmed/34655771 http://dx.doi.org/10.1016/j.neuroimage.2021.118641 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license |
spellingShingle | Article Wang, Fuyixue Dong, Zijing Wald, Lawrence L. Polimeni, Jonathan R. Setsompop, Kawin Simultaneous pure T(2) and varying T(2)′-weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses |
title | Simultaneous pure T(2) and varying T(2)′-weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses |
title_full | Simultaneous pure T(2) and varying T(2)′-weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses |
title_fullStr | Simultaneous pure T(2) and varying T(2)′-weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses |
title_full_unstemmed | Simultaneous pure T(2) and varying T(2)′-weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses |
title_short | Simultaneous pure T(2) and varying T(2)′-weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses |
title_sort | simultaneous pure t(2) and varying t(2)′-weighted bold fmri using echo planar time-resolved imaging for mapping cortical-depth dependent responses |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8820652/ https://www.ncbi.nlm.nih.gov/pubmed/34655771 http://dx.doi.org/10.1016/j.neuroimage.2021.118641 |
work_keys_str_mv | AT wangfuyixue simultaneouspuret2andvaryingt2weightedboldfmriusingechoplanartimeresolvedimagingformappingcorticaldepthdependentresponses AT dongzijing simultaneouspuret2andvaryingt2weightedboldfmriusingechoplanartimeresolvedimagingformappingcorticaldepthdependentresponses AT waldlawrencel simultaneouspuret2andvaryingt2weightedboldfmriusingechoplanartimeresolvedimagingformappingcorticaldepthdependentresponses AT polimenijonathanr simultaneouspuret2andvaryingt2weightedboldfmriusingechoplanartimeresolvedimagingformappingcorticaldepthdependentresponses AT setsompopkawin simultaneouspuret2andvaryingt2weightedboldfmriusingechoplanartimeresolvedimagingformappingcorticaldepthdependentresponses |