Cargando…

Effect of CAD/CAM Guide Plate Combined With Socket-Shield Technique in Immediate Implantation of Anterior Teeth Aesthetic Area and Its Influence on Aesthetics

PURPOSE: The purpose of this study is to discuss the effect of computer-aided design or computer-aided manufacturing (CAD/CAM) guide plate combined with socket-shield technique (SST) in immediate implantation of anterior teeth aesthetic area and its influence on aesthetics. METHODS: A total of 102 p...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Zhigang, Liu, Jianwei, Wang, Xinquan, Wang, Ning, Teng, Min
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8821654/
https://www.ncbi.nlm.nih.gov/pubmed/35145994
http://dx.doi.org/10.3389/fsurg.2021.833288
_version_ 1784646446622965760
author Wang, Zhigang
Liu, Jianwei
Wang, Xinquan
Wang, Ning
Teng, Min
author_facet Wang, Zhigang
Liu, Jianwei
Wang, Xinquan
Wang, Ning
Teng, Min
author_sort Wang, Zhigang
collection PubMed
description PURPOSE: The purpose of this study is to discuss the effect of computer-aided design or computer-aided manufacturing (CAD/CAM) guide plate combined with socket-shield technique (SST) in immediate implantation of anterior teeth aesthetic area and its influence on aesthetics. METHODS: A total of 102 patients with immediate implantation in our hospital from March 2017 to March 2020 were selected. According to different repair methods, patients were divided into conventional group (n = 51) and observation group (n = 51). Traditional immediate implantation was performed in conventional group. The observation group underwent immediate implantation with CAD/CAM guides combined with SST. Immediately after operation and 12 months after operation, the success rate, implant deviation, periodontal index, absorption of labial bone plate, complications, aesthetic effects, and satisfaction of the two groups were observed. RESULTS: There was no significant difference in the success rate between the two groups (p > 0.05). The implant deviation values in the observation group were all lower than those in the conventional group (p < 0.05). PD, PLI, and SBI in the observation group were all lower than those in the conventional group (p < 0.05). The absorption value of labial bone plate in the observation group were all lower than those in the conventional group (p < 0.05). The total incidence of complications in the observation group (5.88%) was lower than that in the conventional group (19.61%) (p < 0.05). The PES and WES in the observation group were higher than those in the conventional group (p < 0.05). The total satisfaction in the observation group (92.16%) was higher than that in the conventional group (76.47%) (p < 0.05). CONCLUSION: : The application of CAD/CAM guide plate combined with SST in immediate implantation of anterior teeth aesthetic area has a good effect, which can improve the accuracy of implantation, improve the periodontal environment, reduce bone resorption, reduce complications, improve aesthetics, and have high patient's satisfaction.
format Online
Article
Text
id pubmed-8821654
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-88216542022-02-09 Effect of CAD/CAM Guide Plate Combined With Socket-Shield Technique in Immediate Implantation of Anterior Teeth Aesthetic Area and Its Influence on Aesthetics Wang, Zhigang Liu, Jianwei Wang, Xinquan Wang, Ning Teng, Min Front Surg Surgery PURPOSE: The purpose of this study is to discuss the effect of computer-aided design or computer-aided manufacturing (CAD/CAM) guide plate combined with socket-shield technique (SST) in immediate implantation of anterior teeth aesthetic area and its influence on aesthetics. METHODS: A total of 102 patients with immediate implantation in our hospital from March 2017 to March 2020 were selected. According to different repair methods, patients were divided into conventional group (n = 51) and observation group (n = 51). Traditional immediate implantation was performed in conventional group. The observation group underwent immediate implantation with CAD/CAM guides combined with SST. Immediately after operation and 12 months after operation, the success rate, implant deviation, periodontal index, absorption of labial bone plate, complications, aesthetic effects, and satisfaction of the two groups were observed. RESULTS: There was no significant difference in the success rate between the two groups (p > 0.05). The implant deviation values in the observation group were all lower than those in the conventional group (p < 0.05). PD, PLI, and SBI in the observation group were all lower than those in the conventional group (p < 0.05). The absorption value of labial bone plate in the observation group were all lower than those in the conventional group (p < 0.05). The total incidence of complications in the observation group (5.88%) was lower than that in the conventional group (19.61%) (p < 0.05). The PES and WES in the observation group were higher than those in the conventional group (p < 0.05). The total satisfaction in the observation group (92.16%) was higher than that in the conventional group (76.47%) (p < 0.05). CONCLUSION: : The application of CAD/CAM guide plate combined with SST in immediate implantation of anterior teeth aesthetic area has a good effect, which can improve the accuracy of implantation, improve the periodontal environment, reduce bone resorption, reduce complications, improve aesthetics, and have high patient's satisfaction. Frontiers Media S.A. 2022-01-25 /pmc/articles/PMC8821654/ /pubmed/35145994 http://dx.doi.org/10.3389/fsurg.2021.833288 Text en Copyright © 2022 Wang, Liu, Wang, Wang and Teng. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Surgery
Wang, Zhigang
Liu, Jianwei
Wang, Xinquan
Wang, Ning
Teng, Min
Effect of CAD/CAM Guide Plate Combined With Socket-Shield Technique in Immediate Implantation of Anterior Teeth Aesthetic Area and Its Influence on Aesthetics
title Effect of CAD/CAM Guide Plate Combined With Socket-Shield Technique in Immediate Implantation of Anterior Teeth Aesthetic Area and Its Influence on Aesthetics
title_full Effect of CAD/CAM Guide Plate Combined With Socket-Shield Technique in Immediate Implantation of Anterior Teeth Aesthetic Area and Its Influence on Aesthetics
title_fullStr Effect of CAD/CAM Guide Plate Combined With Socket-Shield Technique in Immediate Implantation of Anterior Teeth Aesthetic Area and Its Influence on Aesthetics
title_full_unstemmed Effect of CAD/CAM Guide Plate Combined With Socket-Shield Technique in Immediate Implantation of Anterior Teeth Aesthetic Area and Its Influence on Aesthetics
title_short Effect of CAD/CAM Guide Plate Combined With Socket-Shield Technique in Immediate Implantation of Anterior Teeth Aesthetic Area and Its Influence on Aesthetics
title_sort effect of cad/cam guide plate combined with socket-shield technique in immediate implantation of anterior teeth aesthetic area and its influence on aesthetics
topic Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8821654/
https://www.ncbi.nlm.nih.gov/pubmed/35145994
http://dx.doi.org/10.3389/fsurg.2021.833288
work_keys_str_mv AT wangzhigang effectofcadcamguideplatecombinedwithsocketshieldtechniqueinimmediateimplantationofanteriorteethaestheticareaanditsinfluenceonaesthetics
AT liujianwei effectofcadcamguideplatecombinedwithsocketshieldtechniqueinimmediateimplantationofanteriorteethaestheticareaanditsinfluenceonaesthetics
AT wangxinquan effectofcadcamguideplatecombinedwithsocketshieldtechniqueinimmediateimplantationofanteriorteethaestheticareaanditsinfluenceonaesthetics
AT wangning effectofcadcamguideplatecombinedwithsocketshieldtechniqueinimmediateimplantationofanteriorteethaestheticareaanditsinfluenceonaesthetics
AT tengmin effectofcadcamguideplatecombinedwithsocketshieldtechniqueinimmediateimplantationofanteriorteethaestheticareaanditsinfluenceonaesthetics