Cargando…

Electro-characteristics of Myocardial Pouches and Reduction of the Frequency of Steam Pops During Radiofrequency Ablation

Background: Radiofrequency ablation (RFA) effectively treats arrhythmia. Steam pop (SP) is a dangerous complication of RFA, which can lead to pericardial tamponade or even death. Objective: This study aimed to explore the electro-characteristics of myocardial pouches, and the relationship between SP...

Descripción completa

Detalles Bibliográficos
Autores principales: Luo, Jianfeng, Guo, Fei, Zhu, Hongjun, Su, Hao, Wu, Yuanbo, Zhu, Jing, Zhang, Can, Xu, Jian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8821915/
https://www.ncbi.nlm.nih.gov/pubmed/35145433
http://dx.doi.org/10.3389/fphys.2022.816865
_version_ 1784646499361095680
author Luo, Jianfeng
Guo, Fei
Zhu, Hongjun
Su, Hao
Wu, Yuanbo
Zhu, Jing
Zhang, Can
Xu, Jian
author_facet Luo, Jianfeng
Guo, Fei
Zhu, Hongjun
Su, Hao
Wu, Yuanbo
Zhu, Jing
Zhang, Can
Xu, Jian
author_sort Luo, Jianfeng
collection PubMed
description Background: Radiofrequency ablation (RFA) effectively treats arrhythmia. Steam pop (SP) is a dangerous complication of RFA, which can lead to pericardial tamponade or even death. Objective: This study aimed to explore the electro-characteristics of myocardial pouches, and the relationship between SP, pouch, and impedance. Methods: Swine myocardium was divided into the pouch group and smooth myocardium group. Continuous RFA at 50 W was applied. The initial impedance reduction within the first 3 s of ablation and the time from the start of ablation to SP were recorded. After enabling the delta impedance cutoff function, RFA was performed at different percentage of delta impedance (PDI) cutoff thresholds. Results: The impedance was higher for the pouch myocardium compared to the smooth myocardium (123.22 ± 8.63 Ω and 95.75 ± 4.75 Ω, respectively; p < 0.001). The RFA duration before SPs was shorter in the pouch group compared to the smooth myocardium group [9 s (interquartile range, IQR: 6.25–13 s) and 33 s (IQR: 26.25–40.75 s), respectively; p < 0.001]. Within the first 3 s of RFA, impedance reduction (24.65 ± 6.57 Ω and 12.78 ± 3.35 Ω, respectively; p < 0.001) and PDI [19.18% (IQR: 16.39–24.20%) and 12.96% (IQR: 11.17–14.39%), respectively; p < 0.001] were greater in the pouch group compared to the smooth myocardium group. A PDI of 15% and delta time of 3 s effectively reduced the frequency of SPs without seriously affecting RFA use. Conclusion: SPs occur more frequently in the pouch area during RFA. Appropriate delta impedance cutoff settings (PDI: 15%; delta time: 3 s) can reduce the frequency of SPs and improve the RFA safety.
format Online
Article
Text
id pubmed-8821915
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-88219152022-02-09 Electro-characteristics of Myocardial Pouches and Reduction of the Frequency of Steam Pops During Radiofrequency Ablation Luo, Jianfeng Guo, Fei Zhu, Hongjun Su, Hao Wu, Yuanbo Zhu, Jing Zhang, Can Xu, Jian Front Physiol Physiology Background: Radiofrequency ablation (RFA) effectively treats arrhythmia. Steam pop (SP) is a dangerous complication of RFA, which can lead to pericardial tamponade or even death. Objective: This study aimed to explore the electro-characteristics of myocardial pouches, and the relationship between SP, pouch, and impedance. Methods: Swine myocardium was divided into the pouch group and smooth myocardium group. Continuous RFA at 50 W was applied. The initial impedance reduction within the first 3 s of ablation and the time from the start of ablation to SP were recorded. After enabling the delta impedance cutoff function, RFA was performed at different percentage of delta impedance (PDI) cutoff thresholds. Results: The impedance was higher for the pouch myocardium compared to the smooth myocardium (123.22 ± 8.63 Ω and 95.75 ± 4.75 Ω, respectively; p < 0.001). The RFA duration before SPs was shorter in the pouch group compared to the smooth myocardium group [9 s (interquartile range, IQR: 6.25–13 s) and 33 s (IQR: 26.25–40.75 s), respectively; p < 0.001]. Within the first 3 s of RFA, impedance reduction (24.65 ± 6.57 Ω and 12.78 ± 3.35 Ω, respectively; p < 0.001) and PDI [19.18% (IQR: 16.39–24.20%) and 12.96% (IQR: 11.17–14.39%), respectively; p < 0.001] were greater in the pouch group compared to the smooth myocardium group. A PDI of 15% and delta time of 3 s effectively reduced the frequency of SPs without seriously affecting RFA use. Conclusion: SPs occur more frequently in the pouch area during RFA. Appropriate delta impedance cutoff settings (PDI: 15%; delta time: 3 s) can reduce the frequency of SPs and improve the RFA safety. Frontiers Media S.A. 2022-01-25 /pmc/articles/PMC8821915/ /pubmed/35145433 http://dx.doi.org/10.3389/fphys.2022.816865 Text en Copyright © 2022 Luo, Guo, Zhu, Su, Wu, Zhu, Zhang and Xu. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Physiology
Luo, Jianfeng
Guo, Fei
Zhu, Hongjun
Su, Hao
Wu, Yuanbo
Zhu, Jing
Zhang, Can
Xu, Jian
Electro-characteristics of Myocardial Pouches and Reduction of the Frequency of Steam Pops During Radiofrequency Ablation
title Electro-characteristics of Myocardial Pouches and Reduction of the Frequency of Steam Pops During Radiofrequency Ablation
title_full Electro-characteristics of Myocardial Pouches and Reduction of the Frequency of Steam Pops During Radiofrequency Ablation
title_fullStr Electro-characteristics of Myocardial Pouches and Reduction of the Frequency of Steam Pops During Radiofrequency Ablation
title_full_unstemmed Electro-characteristics of Myocardial Pouches and Reduction of the Frequency of Steam Pops During Radiofrequency Ablation
title_short Electro-characteristics of Myocardial Pouches and Reduction of the Frequency of Steam Pops During Radiofrequency Ablation
title_sort electro-characteristics of myocardial pouches and reduction of the frequency of steam pops during radiofrequency ablation
topic Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8821915/
https://www.ncbi.nlm.nih.gov/pubmed/35145433
http://dx.doi.org/10.3389/fphys.2022.816865
work_keys_str_mv AT luojianfeng electrocharacteristicsofmyocardialpouchesandreductionofthefrequencyofsteampopsduringradiofrequencyablation
AT guofei electrocharacteristicsofmyocardialpouchesandreductionofthefrequencyofsteampopsduringradiofrequencyablation
AT zhuhongjun electrocharacteristicsofmyocardialpouchesandreductionofthefrequencyofsteampopsduringradiofrequencyablation
AT suhao electrocharacteristicsofmyocardialpouchesandreductionofthefrequencyofsteampopsduringradiofrequencyablation
AT wuyuanbo electrocharacteristicsofmyocardialpouchesandreductionofthefrequencyofsteampopsduringradiofrequencyablation
AT zhujing electrocharacteristicsofmyocardialpouchesandreductionofthefrequencyofsteampopsduringradiofrequencyablation
AT zhangcan electrocharacteristicsofmyocardialpouchesandreductionofthefrequencyofsteampopsduringradiofrequencyablation
AT xujian electrocharacteristicsofmyocardialpouchesandreductionofthefrequencyofsteampopsduringradiofrequencyablation