Cargando…

Carbon dots hybrid for dual fluorescent detection of microRNA-21 integrated bioimaging of MCF-7 using a microfluidic platform

BACKGROUND: MicroRNAs have short sequences of 20 ~ 25-nucleotides which are similar among family members and play crucial regulatory roles in numerous biological processes, such as in cell development, metabolism, proliferation, differentiation, and apoptosis. RESULTS: We reported a strategy for the...

Descripción completa

Detalles Bibliográficos
Autores principales: Mohammadi, Somayeh, Salimi, Abdollah, Hoseinkhani, Zohreh, Ghasemi, Foad, Mansouri, Kamran
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8822830/
https://www.ncbi.nlm.nih.gov/pubmed/35135571
http://dx.doi.org/10.1186/s12951-022-01274-3
Descripción
Sumario:BACKGROUND: MicroRNAs have short sequences of 20 ~ 25-nucleotides which are similar among family members and play crucial regulatory roles in numerous biological processes, such as in cell development, metabolism, proliferation, differentiation, and apoptosis. RESULTS: We reported a strategy for the construction of a dual-emission fluorescent sensor using carbon dots (CDs) and confirmed their applications for ratiometric microRNA-21 sensing and bioimaging of cancer cells in a microfluidic device. The composition of blue CDs (B-CDs) and yellow CDs (Y-CDs) depicts dual-emission behavior which is centered at 409 and 543 nm under an excitation wavelength of 360 nm. With increasing microRNA-21 concentration, the robust and specific binding of DNA probe functionalized B-CDs to complementary microRNA-21 target induced perturbations of probe structure and led to changing fluorescence intensity in both wavelengths. Consequently, the ratio of turn-on signal to turn-off signal is greatly altered. With monitoring of the inherent ratiometric fluorescence variation (ΔF(540nm)/ΔF(410nm)), as-prepared BY-CDs were established as an efficient platform for ratiometric fluorescent microRNA-21 sensing, with a wide linear range of 0.15 fM to 2.46 pM and a detection limit of 50 aM. CONCLUSIONS: Furthermore, the proposed assay was applied for detecting microRNA-21 in dilute human serum samples with satisfactory recovery and also in MCF-7 cell lines in the range 3000 to 45,000 (cell mL(−1)) with a detection limit (3 cells in 10 μL), demonstrating the potential of the assay for clinic diagnosis of microRNA-associated disease. More importantly, the images revealed that MCF-7 cells well labeled with BY-CDs could exhibit the applicability of the proposed microfluidic system as an effective cell trapping device in bioimaging. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12951-022-01274-3.