4511 Bio-Compatible Implantable Oxygen Sensor Technology with Real-Time Monitoring of Surgical Flaps and Reimplantation

OBJECTIVES/GOALS: Current surgical flap and replantation monitoring techniques have limitations in detecting the pathologic state, calibration and cost-to-patient issues. Our hypothesis is that novel implantable oxygen sensors can provide a more efficient, accurate, and reliable monitoring of tissue...

Descripción completa

Detalles Bibliográficos
Autores principales: Patel, Preet, Ibrahim, Mohamed, Klitzman, Bruce
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cambridge University Press 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8823536/
http://dx.doi.org/10.1017/cts.2020.292
_version_ 1784646821965987840
author Patel, Preet
Ibrahim, Mohamed
Klitzman, Bruce
author_facet Patel, Preet
Ibrahim, Mohamed
Klitzman, Bruce
author_sort Patel, Preet
collection PubMed
description OBJECTIVES/GOALS: Current surgical flap and replantation monitoring techniques have limitations in detecting the pathologic state, calibration and cost-to-patient issues. Our hypothesis is that novel implantable oxygen sensors can provide a more efficient, accurate, and reliable monitoring of tissue oxygenation. METHODS/STUDY POPULATION: Experimental sensors were used with an exogenous remote used as a reader once implanted (Fig. 1) A rat tissue perfusion model with three regions of an SIEA flap as well as into adjacent control sites was made (Tip, Middle, and Base) Blood flow was greatest at the base, diminishing towards the Tip, thus creating a perfusion gradient. Changes in tissue oxygen tension PO2 were estimated by the steady-state fluorescence of the optical sensors using an IVIS imaging system. The sensors were used to collect data from days 0, 3, and 7 as a reading of Tissue Oxygen Tension (TOT) with ANOVA used to assess for statistical significance in blood oxygen data with respect to relative perfusion status. RESULTS/ANTICIPATED RESULTS: Inspired FiO2 was decreased from 100% to 12% with a corresponding change in the TOT readings from all sensors. (Fig. 2) The tip portion of the flap demonstrated the most profound detection of tissue necrosis, with the middle demonstrating the second most necrosis and the base demonstrating the least with correlating TOT sensor readings. (Fig. 3) Acute vascular compromise of the feeding blood vessels in the pedicle was immediately detected within 70 seconds (*p<0.05). (Fig. 4) DISCUSSION/SIGNIFICANCE OF IMPACT: This study introduces and validates a recent technique to monitor acute vascular occlusion, flap viability, and necrosis in the immediate postoperative period in a validated rodent model. Future directions of this novel technology will aim to reproduce these findings in clinical feasibility studies.
format Online
Article
Text
id pubmed-8823536
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Cambridge University Press
record_format MEDLINE/PubMed
spelling pubmed-88235362022-02-18 4511 Bio-Compatible Implantable Oxygen Sensor Technology with Real-Time Monitoring of Surgical Flaps and Reimplantation Patel, Preet Ibrahim, Mohamed Klitzman, Bruce J Clin Transl Sci Mechanistic Basic to Clinical OBJECTIVES/GOALS: Current surgical flap and replantation monitoring techniques have limitations in detecting the pathologic state, calibration and cost-to-patient issues. Our hypothesis is that novel implantable oxygen sensors can provide a more efficient, accurate, and reliable monitoring of tissue oxygenation. METHODS/STUDY POPULATION: Experimental sensors were used with an exogenous remote used as a reader once implanted (Fig. 1) A rat tissue perfusion model with three regions of an SIEA flap as well as into adjacent control sites was made (Tip, Middle, and Base) Blood flow was greatest at the base, diminishing towards the Tip, thus creating a perfusion gradient. Changes in tissue oxygen tension PO2 were estimated by the steady-state fluorescence of the optical sensors using an IVIS imaging system. The sensors were used to collect data from days 0, 3, and 7 as a reading of Tissue Oxygen Tension (TOT) with ANOVA used to assess for statistical significance in blood oxygen data with respect to relative perfusion status. RESULTS/ANTICIPATED RESULTS: Inspired FiO2 was decreased from 100% to 12% with a corresponding change in the TOT readings from all sensors. (Fig. 2) The tip portion of the flap demonstrated the most profound detection of tissue necrosis, with the middle demonstrating the second most necrosis and the base demonstrating the least with correlating TOT sensor readings. (Fig. 3) Acute vascular compromise of the feeding blood vessels in the pedicle was immediately detected within 70 seconds (*p<0.05). (Fig. 4) DISCUSSION/SIGNIFICANCE OF IMPACT: This study introduces and validates a recent technique to monitor acute vascular occlusion, flap viability, and necrosis in the immediate postoperative period in a validated rodent model. Future directions of this novel technology will aim to reproduce these findings in clinical feasibility studies. Cambridge University Press 2020-07-29 /pmc/articles/PMC8823536/ http://dx.doi.org/10.1017/cts.2020.292 Text en © The Association for Clinical and Translational Science 2020 https://creativecommons.org/licenses/by/4.0/This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Mechanistic Basic to Clinical
Patel, Preet
Ibrahim, Mohamed
Klitzman, Bruce
4511 Bio-Compatible Implantable Oxygen Sensor Technology with Real-Time Monitoring of Surgical Flaps and Reimplantation
title 4511 Bio-Compatible Implantable Oxygen Sensor Technology with Real-Time Monitoring of Surgical Flaps and Reimplantation
title_full 4511 Bio-Compatible Implantable Oxygen Sensor Technology with Real-Time Monitoring of Surgical Flaps and Reimplantation
title_fullStr 4511 Bio-Compatible Implantable Oxygen Sensor Technology with Real-Time Monitoring of Surgical Flaps and Reimplantation
title_full_unstemmed 4511 Bio-Compatible Implantable Oxygen Sensor Technology with Real-Time Monitoring of Surgical Flaps and Reimplantation
title_short 4511 Bio-Compatible Implantable Oxygen Sensor Technology with Real-Time Monitoring of Surgical Flaps and Reimplantation
title_sort 4511 bio-compatible implantable oxygen sensor technology with real-time monitoring of surgical flaps and reimplantation
topic Mechanistic Basic to Clinical
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8823536/
http://dx.doi.org/10.1017/cts.2020.292
work_keys_str_mv AT patelpreet 4511biocompatibleimplantableoxygensensortechnologywithrealtimemonitoringofsurgicalflapsandreimplantation
AT ibrahimmohamed 4511biocompatibleimplantableoxygensensortechnologywithrealtimemonitoringofsurgicalflapsandreimplantation
AT klitzmanbruce 4511biocompatibleimplantableoxygensensortechnologywithrealtimemonitoringofsurgicalflapsandreimplantation