AIM: This study aims to compare novice performance of advanced bimanual laparoscopic skills using an articulating laparoscopic device (FlexDex™) compared to a standard rigid needle holder amongst surgical novices in 2-dimension (2D) visualisation. METHODS: In this prospective randomised trial, novic...

Descripción completa

Detalles Bibliográficos
Autores principales: Motahariasl, Nima, Farzaneh, Sayed Borna, Motahariasl, Sina, Kokotkin, Ilya, Sousi, Sara, Zargaran, Alexander, Zargaran, David, Patel, Bijendra
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8824294/
https://www.ncbi.nlm.nih.gov/pubmed/35153517
http://dx.doi.org/10.2147/MDER.S345140
_version_ 1784646984004534272
author Motahariasl, Nima
Farzaneh, Sayed Borna
Motahariasl, Sina
Kokotkin, Ilya
Sousi, Sara
Zargaran, Alexander
Zargaran, David
Patel, Bijendra
author_facet Motahariasl, Nima
Farzaneh, Sayed Borna
Motahariasl, Sina
Kokotkin, Ilya
Sousi, Sara
Zargaran, Alexander
Zargaran, David
Patel, Bijendra
author_sort Motahariasl, Nima
collection PubMed
description AIM: This study aims to compare novice performance of advanced bimanual laparoscopic skills using an articulating laparoscopic device (FlexDex™) compared to a standard rigid needle holder amongst surgical novices in 2-dimension (2D) visualisation. METHODS: In this prospective randomised trial, novices (n = 40) without laparoscopic experience were recruited and randomised into two groups, which used either traditional rigid needle holders or the FlexDex™. Both groups performed 10 repetitions of a validated assessment task. Times taken and error rates were recorded, and results were evaluated based on completion times, error rates, and learning curves. RESULTS: The intervention group that used the FlexDex™ completed 10 attempts of the standardised laparoscopic task slower than the control group that used traditional rigid needle holder (415 s versus 267 s taken for the first three attempts and 283 s versus 187 s taken for the last three attempts, respectively). The difference in average time for the first three and last three attempts reached statistical significance (P < 0.001). Furthermore, the intervention group demonstrated a higher error rate when compared to the control group (9.3 versus 6.2 errors per individual). CONCLUSION: When compared to the FlexDex™, the traditional rigid needle holder was observed to be superior in task performance speed, leading to shorter completion times and quicker learning effect, as well as fewer errors. KEY STATEMENT: Traditional rigid needle holder leads to faster task completion times and lower error rates when compared with an articulating laparoscopic needle holder in 2D vision.
format Online
Article
Text
id pubmed-8824294
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-88242942022-02-10 Assessment of an Articulating Laparoscopic Needle Holder (FlexDex™) Compared to a Conventional Rigid Needle Holder in 2-Dimension Vision Amongst Novices: A Randomised Controlled Study Motahariasl, Nima Farzaneh, Sayed Borna Motahariasl, Sina Kokotkin, Ilya Sousi, Sara Zargaran, Alexander Zargaran, David Patel, Bijendra Med Devices (Auckl) Original Research AIM: This study aims to compare novice performance of advanced bimanual laparoscopic skills using an articulating laparoscopic device (FlexDex™) compared to a standard rigid needle holder amongst surgical novices in 2-dimension (2D) visualisation. METHODS: In this prospective randomised trial, novices (n = 40) without laparoscopic experience were recruited and randomised into two groups, which used either traditional rigid needle holders or the FlexDex™. Both groups performed 10 repetitions of a validated assessment task. Times taken and error rates were recorded, and results were evaluated based on completion times, error rates, and learning curves. RESULTS: The intervention group that used the FlexDex™ completed 10 attempts of the standardised laparoscopic task slower than the control group that used traditional rigid needle holder (415 s versus 267 s taken for the first three attempts and 283 s versus 187 s taken for the last three attempts, respectively). The difference in average time for the first three and last three attempts reached statistical significance (P < 0.001). Furthermore, the intervention group demonstrated a higher error rate when compared to the control group (9.3 versus 6.2 errors per individual). CONCLUSION: When compared to the FlexDex™, the traditional rigid needle holder was observed to be superior in task performance speed, leading to shorter completion times and quicker learning effect, as well as fewer errors. KEY STATEMENT: Traditional rigid needle holder leads to faster task completion times and lower error rates when compared with an articulating laparoscopic needle holder in 2D vision. Dove 2022-02-04 /pmc/articles/PMC8824294/ /pubmed/35153517 http://dx.doi.org/10.2147/MDER.S345140 Text en © 2022 Motahariasl et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Motahariasl, Nima
Farzaneh, Sayed Borna
Motahariasl, Sina
Kokotkin, Ilya
Sousi, Sara
Zargaran, Alexander
Zargaran, David
Patel, Bijendra
Assessment of an Articulating Laparoscopic Needle Holder (FlexDex™) Compared to a Conventional Rigid Needle Holder in 2-Dimension Vision Amongst Novices: A Randomised Controlled Study
title Assessment of an Articulating Laparoscopic Needle Holder (FlexDex™) Compared to a Conventional Rigid Needle Holder in 2-Dimension Vision Amongst Novices: A Randomised Controlled Study
title_full Assessment of an Articulating Laparoscopic Needle Holder (FlexDex™) Compared to a Conventional Rigid Needle Holder in 2-Dimension Vision Amongst Novices: A Randomised Controlled Study
title_fullStr Assessment of an Articulating Laparoscopic Needle Holder (FlexDex™) Compared to a Conventional Rigid Needle Holder in 2-Dimension Vision Amongst Novices: A Randomised Controlled Study
title_full_unstemmed Assessment of an Articulating Laparoscopic Needle Holder (FlexDex™) Compared to a Conventional Rigid Needle Holder in 2-Dimension Vision Amongst Novices: A Randomised Controlled Study
title_short Assessment of an Articulating Laparoscopic Needle Holder (FlexDex™) Compared to a Conventional Rigid Needle Holder in 2-Dimension Vision Amongst Novices: A Randomised Controlled Study
title_sort assessment of an articulating laparoscopic needle holder (flexdex™) compared to a conventional rigid needle holder in 2-dimension vision amongst novices: a randomised controlled study
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8824294/
https://www.ncbi.nlm.nih.gov/pubmed/35153517
http://dx.doi.org/10.2147/MDER.S345140
work_keys_str_mv AT motahariaslnima assessmentofanarticulatinglaparoscopicneedleholderflexdexcomparedtoaconventionalrigidneedleholderin2dimensionvisionamongstnovicesarandomisedcontrolledstudy
AT farzanehsayedborna assessmentofanarticulatinglaparoscopicneedleholderflexdexcomparedtoaconventionalrigidneedleholderin2dimensionvisionamongstnovicesarandomisedcontrolledstudy
AT motahariaslsina assessmentofanarticulatinglaparoscopicneedleholderflexdexcomparedtoaconventionalrigidneedleholderin2dimensionvisionamongstnovicesarandomisedcontrolledstudy
AT kokotkinilya assessmentofanarticulatinglaparoscopicneedleholderflexdexcomparedtoaconventionalrigidneedleholderin2dimensionvisionamongstnovicesarandomisedcontrolledstudy
AT sousisara assessmentofanarticulatinglaparoscopicneedleholderflexdexcomparedtoaconventionalrigidneedleholderin2dimensionvisionamongstnovicesarandomisedcontrolledstudy
AT zargaranalexander assessmentofanarticulatinglaparoscopicneedleholderflexdexcomparedtoaconventionalrigidneedleholderin2dimensionvisionamongstnovicesarandomisedcontrolledstudy
AT zargarandavid assessmentofanarticulatinglaparoscopicneedleholderflexdexcomparedtoaconventionalrigidneedleholderin2dimensionvisionamongstnovicesarandomisedcontrolledstudy
AT patelbijendra assessmentofanarticulatinglaparoscopicneedleholderflexdexcomparedtoaconventionalrigidneedleholderin2dimensionvisionamongstnovicesarandomisedcontrolledstudy