Cargando…

Redundancy cancellation of compressed measurements by QRS complex alignment

The demand for long-term continuous care has led healthcare experts to focus on development challenges. On-chip energy consumption as a key challenge can be addressed by data reduction techniques. In this paper, the pseudo periodic nature of ElectroCardioGram(ECG) signals has been used to completely...

Descripción completa

Detalles Bibliográficos
Autores principales: Nasimi, Fahimeh, Khayyambashi, Mohammad Reza, Movahhedinia, Naser
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8824321/
https://www.ncbi.nlm.nih.gov/pubmed/35134070
http://dx.doi.org/10.1371/journal.pone.0262219
_version_ 1784646989576667136
author Nasimi, Fahimeh
Khayyambashi, Mohammad Reza
Movahhedinia, Naser
author_facet Nasimi, Fahimeh
Khayyambashi, Mohammad Reza
Movahhedinia, Naser
author_sort Nasimi, Fahimeh
collection PubMed
description The demand for long-term continuous care has led healthcare experts to focus on development challenges. On-chip energy consumption as a key challenge can be addressed by data reduction techniques. In this paper, the pseudo periodic nature of ElectroCardioGram(ECG) signals has been used to completely remove redundancy from frames. Compressing aligned QRS complexes by Compressed Sensing (CS), result in highly redundant measurement vectors. By removing this redundancy, a high cluster of near zero samples is gained. The efficiency of the proposed algorithm is assessed using the standard MIT-BIH database. The results indicate that by aligning ECG frames, the proposed technique can achieve superior reconstruction quality compared to state-of-the-art techniques for all compression ratios. This study proves that by aligning ECG frames with a 0.05% unaligned frame rate(R-peak detection error), more compression could be gained for PRD > 5% when 5-bit non-uniform quantizer is used. Furthermore, analysis done on power consumption of the proposed technique, indicates that a very good recovery performance can be gained by only consuming 4.9μW more energy per frame compared to traditional CS.
format Online
Article
Text
id pubmed-8824321
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-88243212022-02-09 Redundancy cancellation of compressed measurements by QRS complex alignment Nasimi, Fahimeh Khayyambashi, Mohammad Reza Movahhedinia, Naser PLoS One Research Article The demand for long-term continuous care has led healthcare experts to focus on development challenges. On-chip energy consumption as a key challenge can be addressed by data reduction techniques. In this paper, the pseudo periodic nature of ElectroCardioGram(ECG) signals has been used to completely remove redundancy from frames. Compressing aligned QRS complexes by Compressed Sensing (CS), result in highly redundant measurement vectors. By removing this redundancy, a high cluster of near zero samples is gained. The efficiency of the proposed algorithm is assessed using the standard MIT-BIH database. The results indicate that by aligning ECG frames, the proposed technique can achieve superior reconstruction quality compared to state-of-the-art techniques for all compression ratios. This study proves that by aligning ECG frames with a 0.05% unaligned frame rate(R-peak detection error), more compression could be gained for PRD > 5% when 5-bit non-uniform quantizer is used. Furthermore, analysis done on power consumption of the proposed technique, indicates that a very good recovery performance can be gained by only consuming 4.9μW more energy per frame compared to traditional CS. Public Library of Science 2022-02-08 /pmc/articles/PMC8824321/ /pubmed/35134070 http://dx.doi.org/10.1371/journal.pone.0262219 Text en © 2022 Nasimi et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Nasimi, Fahimeh
Khayyambashi, Mohammad Reza
Movahhedinia, Naser
Redundancy cancellation of compressed measurements by QRS complex alignment
title Redundancy cancellation of compressed measurements by QRS complex alignment
title_full Redundancy cancellation of compressed measurements by QRS complex alignment
title_fullStr Redundancy cancellation of compressed measurements by QRS complex alignment
title_full_unstemmed Redundancy cancellation of compressed measurements by QRS complex alignment
title_short Redundancy cancellation of compressed measurements by QRS complex alignment
title_sort redundancy cancellation of compressed measurements by qrs complex alignment
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8824321/
https://www.ncbi.nlm.nih.gov/pubmed/35134070
http://dx.doi.org/10.1371/journal.pone.0262219
work_keys_str_mv AT nasimifahimeh redundancycancellationofcompressedmeasurementsbyqrscomplexalignment
AT khayyambashimohammadreza redundancycancellationofcompressedmeasurementsbyqrscomplexalignment
AT movahhedinianaser redundancycancellationofcompressedmeasurementsbyqrscomplexalignment