Cargando…
Comparative Analysis of Radiological Evaluation and Early Functional Outcomes of Total Knee Arthroplasty Using an Accelerometer-Based Handheld Navigation System and Conventional Instrumentation: A Prospective Study
Background An accelerometer-based handheld navigation system (HHNS) for total knee arthroplasty (TKA) does not require a large console needed for computer-assisted navigation systems and has been shown to decrease component malalignment in TKA. The study aimed to use HHNS with conventional instrumen...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8824389/ https://www.ncbi.nlm.nih.gov/pubmed/35155007 http://dx.doi.org/10.7759/cureus.21039 |
_version_ | 1784647006080204800 |
---|---|
author | Jagadeesh, Nuthan Kumar, Hiranya sarparaju, Varma Shivalingappa, Vishwanath |
author_facet | Jagadeesh, Nuthan Kumar, Hiranya sarparaju, Varma Shivalingappa, Vishwanath |
author_sort | Jagadeesh, Nuthan |
collection | PubMed |
description | Background An accelerometer-based handheld navigation system (HHNS) for total knee arthroplasty (TKA) does not require a large console needed for computer-assisted navigation systems and has been shown to decrease component malalignment in TKA. The study aimed to use HHNS with conventional instrumentation to compare the radiological evaluation and functional outcomes of TKA. Materials and methods This was a multi-surgeon, prospective, assessor-blinded comparative study of 122 patients undergoing unilateral TKA. We used a stratified randomized sampling method to select 35/48 patients undergoing TKA using a handheld navigation system and 35/74 patients undergoing TKA using conventional instrumentation and divided them into two groups: the HHNS group and (conventional) CONV group. Postoperative radiographic evaluation was based on the tibial and femoral alignment angle, posterior tibial slope, and tibiofemoral angle measured from full-length lower-limb anteroposterior and lateral views of the knee. The Oxford Knee Score (OKS) and Knee Society Score (KSS) with a two-year serial follow-up were used to evaluate functional outcomes. Results The mean tibial alignment angle and posterior tibial slope were 0.78° ± 1.27° and 4.38° ± 0.86°, respectively, in the HHNS cohort and 2.63° ± 1.54° and 2.12° ± 1.82°, respectively, in the CONV group (p < 0.001). There was no significant difference in the femoral alignment angles. The overall alignment using the mean tibiofemoral angle was 179.21° ± 1.82° in the HHNS group and 177.31° ± 2.18° in the CONV group (p = 0.002). There were no significant differences in the KSS and OKS at the two-year follow-up between the groups. Conclusions The use of HHNS in TKA significantly increased accuracy in limb and implant alignment, but there was no significant difference in the two-years functional outcomes. |
format | Online Article Text |
id | pubmed-8824389 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-88243892022-02-11 Comparative Analysis of Radiological Evaluation and Early Functional Outcomes of Total Knee Arthroplasty Using an Accelerometer-Based Handheld Navigation System and Conventional Instrumentation: A Prospective Study Jagadeesh, Nuthan Kumar, Hiranya sarparaju, Varma Shivalingappa, Vishwanath Cureus Orthopedics Background An accelerometer-based handheld navigation system (HHNS) for total knee arthroplasty (TKA) does not require a large console needed for computer-assisted navigation systems and has been shown to decrease component malalignment in TKA. The study aimed to use HHNS with conventional instrumentation to compare the radiological evaluation and functional outcomes of TKA. Materials and methods This was a multi-surgeon, prospective, assessor-blinded comparative study of 122 patients undergoing unilateral TKA. We used a stratified randomized sampling method to select 35/48 patients undergoing TKA using a handheld navigation system and 35/74 patients undergoing TKA using conventional instrumentation and divided them into two groups: the HHNS group and (conventional) CONV group. Postoperative radiographic evaluation was based on the tibial and femoral alignment angle, posterior tibial slope, and tibiofemoral angle measured from full-length lower-limb anteroposterior and lateral views of the knee. The Oxford Knee Score (OKS) and Knee Society Score (KSS) with a two-year serial follow-up were used to evaluate functional outcomes. Results The mean tibial alignment angle and posterior tibial slope were 0.78° ± 1.27° and 4.38° ± 0.86°, respectively, in the HHNS cohort and 2.63° ± 1.54° and 2.12° ± 1.82°, respectively, in the CONV group (p < 0.001). There was no significant difference in the femoral alignment angles. The overall alignment using the mean tibiofemoral angle was 179.21° ± 1.82° in the HHNS group and 177.31° ± 2.18° in the CONV group (p = 0.002). There were no significant differences in the KSS and OKS at the two-year follow-up between the groups. Conclusions The use of HHNS in TKA significantly increased accuracy in limb and implant alignment, but there was no significant difference in the two-years functional outcomes. Cureus 2022-01-09 /pmc/articles/PMC8824389/ /pubmed/35155007 http://dx.doi.org/10.7759/cureus.21039 Text en Copyright © 2022, Jagadeesh et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Orthopedics Jagadeesh, Nuthan Kumar, Hiranya sarparaju, Varma Shivalingappa, Vishwanath Comparative Analysis of Radiological Evaluation and Early Functional Outcomes of Total Knee Arthroplasty Using an Accelerometer-Based Handheld Navigation System and Conventional Instrumentation: A Prospective Study |
title | Comparative Analysis of Radiological Evaluation and Early Functional Outcomes of Total Knee Arthroplasty Using an Accelerometer-Based Handheld Navigation System and Conventional Instrumentation: A Prospective Study |
title_full | Comparative Analysis of Radiological Evaluation and Early Functional Outcomes of Total Knee Arthroplasty Using an Accelerometer-Based Handheld Navigation System and Conventional Instrumentation: A Prospective Study |
title_fullStr | Comparative Analysis of Radiological Evaluation and Early Functional Outcomes of Total Knee Arthroplasty Using an Accelerometer-Based Handheld Navigation System and Conventional Instrumentation: A Prospective Study |
title_full_unstemmed | Comparative Analysis of Radiological Evaluation and Early Functional Outcomes of Total Knee Arthroplasty Using an Accelerometer-Based Handheld Navigation System and Conventional Instrumentation: A Prospective Study |
title_short | Comparative Analysis of Radiological Evaluation and Early Functional Outcomes of Total Knee Arthroplasty Using an Accelerometer-Based Handheld Navigation System and Conventional Instrumentation: A Prospective Study |
title_sort | comparative analysis of radiological evaluation and early functional outcomes of total knee arthroplasty using an accelerometer-based handheld navigation system and conventional instrumentation: a prospective study |
topic | Orthopedics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8824389/ https://www.ncbi.nlm.nih.gov/pubmed/35155007 http://dx.doi.org/10.7759/cureus.21039 |
work_keys_str_mv | AT jagadeeshnuthan comparativeanalysisofradiologicalevaluationandearlyfunctionaloutcomesoftotalkneearthroplastyusinganaccelerometerbasedhandheldnavigationsystemandconventionalinstrumentationaprospectivestudy AT kumarhiranya comparativeanalysisofradiologicalevaluationandearlyfunctionaloutcomesoftotalkneearthroplastyusinganaccelerometerbasedhandheldnavigationsystemandconventionalinstrumentationaprospectivestudy AT sarparajuvarma comparativeanalysisofradiologicalevaluationandearlyfunctionaloutcomesoftotalkneearthroplastyusinganaccelerometerbasedhandheldnavigationsystemandconventionalinstrumentationaprospectivestudy AT shivalingappavishwanath comparativeanalysisofradiologicalevaluationandearlyfunctionaloutcomesoftotalkneearthroplastyusinganaccelerometerbasedhandheldnavigationsystemandconventionalinstrumentationaprospectivestudy |