Cargando…

Supplemental cerclage wiring in angle stable plate fixation of distal tibial spiral fractures enables immediate post-operative full weight-bearing: a biomechanical analysis

PURPOSE: Distal tibial fractures generally require post-operative weight-bearing restrictions. Especially geriatric patients are unable to follow these recommendations. To increase post-operative implant stability and enable early weight-bearing, augmentation of the primary osteosynthesis by cerclag...

Descripción completa

Detalles Bibliográficos
Autores principales: Sandriesser, Sabrina, Förch, Stefan, Mayr, Edgar, Schrödl, Falk, von Rüden, Christian, Augat, Peter
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8825397/
https://www.ncbi.nlm.nih.gov/pubmed/32989509
http://dx.doi.org/10.1007/s00068-020-01503-0
_version_ 1784647200276480000
author Sandriesser, Sabrina
Förch, Stefan
Mayr, Edgar
Schrödl, Falk
von Rüden, Christian
Augat, Peter
author_facet Sandriesser, Sabrina
Förch, Stefan
Mayr, Edgar
Schrödl, Falk
von Rüden, Christian
Augat, Peter
author_sort Sandriesser, Sabrina
collection PubMed
description PURPOSE: Distal tibial fractures generally require post-operative weight-bearing restrictions. Especially geriatric patients are unable to follow these recommendations. To increase post-operative implant stability and enable early weight-bearing, augmentation of the primary osteosynthesis by cerclage is desirable. The purpose of this study was to identify the stabilizing effects of a supplemental cable cerclage following plate fixation of distal tibial spiral fractures compared to solitary plate osteosynthesis. METHODS: In eight synthetic tibiae, a reproducible spiral fracture (AO/OTA 42-A1.1c) was stabilized by angle stable plate fixation. Each specimen was statically loaded under combined axial and torsional loads to simulate partial (200 N, 2 Nm) and full (750 N, 7 Nm) weight-bearing. Tests were repeated with supplemental cable cerclage looped around the fracture zone. In a subsequent stepwise increased dynamic load scenario, construct stiffness and interfragmentary movements were analyzed. RESULTS: With supplemental cable cerclage, construct stiffness almost tripled compared to solitary plate osteosynthesis (2882 ± 739 N/mm vs. 983 ± 355 N/mm; p < 0.001). Under full weight-bearing static loads, a supplemental cerclage revealed reduced axial (− 55%; p = 0.001) and shear movement (− 83%; p < 0.001), and also lowered shear movement (− 42%; p = 0.001) compared to a solitary plate under partial weight-bearing. Under dynamic loads supplemental cerclage significantly reduced axial (p = 0.005) as well as shear movements (p < 0.001). CONCLUSION: Supplemental cable cerclage significantly increases fixation stiffness and reduces shear movement in distal tibial spiral fractures. This stabilizing effect enables from a biomechanical point of view immediate mobilization without any weight-bearing restrictions, which may improve the quality of care of orthopedic patients and may trigger a change towards early weight-bearing regimes, especially geriatric patients would benefit from.
format Online
Article
Text
id pubmed-8825397
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-88253972022-02-23 Supplemental cerclage wiring in angle stable plate fixation of distal tibial spiral fractures enables immediate post-operative full weight-bearing: a biomechanical analysis Sandriesser, Sabrina Förch, Stefan Mayr, Edgar Schrödl, Falk von Rüden, Christian Augat, Peter Eur J Trauma Emerg Surg Original Article PURPOSE: Distal tibial fractures generally require post-operative weight-bearing restrictions. Especially geriatric patients are unable to follow these recommendations. To increase post-operative implant stability and enable early weight-bearing, augmentation of the primary osteosynthesis by cerclage is desirable. The purpose of this study was to identify the stabilizing effects of a supplemental cable cerclage following plate fixation of distal tibial spiral fractures compared to solitary plate osteosynthesis. METHODS: In eight synthetic tibiae, a reproducible spiral fracture (AO/OTA 42-A1.1c) was stabilized by angle stable plate fixation. Each specimen was statically loaded under combined axial and torsional loads to simulate partial (200 N, 2 Nm) and full (750 N, 7 Nm) weight-bearing. Tests were repeated with supplemental cable cerclage looped around the fracture zone. In a subsequent stepwise increased dynamic load scenario, construct stiffness and interfragmentary movements were analyzed. RESULTS: With supplemental cable cerclage, construct stiffness almost tripled compared to solitary plate osteosynthesis (2882 ± 739 N/mm vs. 983 ± 355 N/mm; p < 0.001). Under full weight-bearing static loads, a supplemental cerclage revealed reduced axial (− 55%; p = 0.001) and shear movement (− 83%; p < 0.001), and also lowered shear movement (− 42%; p = 0.001) compared to a solitary plate under partial weight-bearing. Under dynamic loads supplemental cerclage significantly reduced axial (p = 0.005) as well as shear movements (p < 0.001). CONCLUSION: Supplemental cable cerclage significantly increases fixation stiffness and reduces shear movement in distal tibial spiral fractures. This stabilizing effect enables from a biomechanical point of view immediate mobilization without any weight-bearing restrictions, which may improve the quality of care of orthopedic patients and may trigger a change towards early weight-bearing regimes, especially geriatric patients would benefit from. Springer Berlin Heidelberg 2020-09-28 2022 /pmc/articles/PMC8825397/ /pubmed/32989509 http://dx.doi.org/10.1007/s00068-020-01503-0 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Sandriesser, Sabrina
Förch, Stefan
Mayr, Edgar
Schrödl, Falk
von Rüden, Christian
Augat, Peter
Supplemental cerclage wiring in angle stable plate fixation of distal tibial spiral fractures enables immediate post-operative full weight-bearing: a biomechanical analysis
title Supplemental cerclage wiring in angle stable plate fixation of distal tibial spiral fractures enables immediate post-operative full weight-bearing: a biomechanical analysis
title_full Supplemental cerclage wiring in angle stable plate fixation of distal tibial spiral fractures enables immediate post-operative full weight-bearing: a biomechanical analysis
title_fullStr Supplemental cerclage wiring in angle stable plate fixation of distal tibial spiral fractures enables immediate post-operative full weight-bearing: a biomechanical analysis
title_full_unstemmed Supplemental cerclage wiring in angle stable plate fixation of distal tibial spiral fractures enables immediate post-operative full weight-bearing: a biomechanical analysis
title_short Supplemental cerclage wiring in angle stable plate fixation of distal tibial spiral fractures enables immediate post-operative full weight-bearing: a biomechanical analysis
title_sort supplemental cerclage wiring in angle stable plate fixation of distal tibial spiral fractures enables immediate post-operative full weight-bearing: a biomechanical analysis
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8825397/
https://www.ncbi.nlm.nih.gov/pubmed/32989509
http://dx.doi.org/10.1007/s00068-020-01503-0
work_keys_str_mv AT sandriessersabrina supplementalcerclagewiringinanglestableplatefixationofdistaltibialspiralfracturesenablesimmediatepostoperativefullweightbearingabiomechanicalanalysis
AT forchstefan supplementalcerclagewiringinanglestableplatefixationofdistaltibialspiralfracturesenablesimmediatepostoperativefullweightbearingabiomechanicalanalysis
AT mayredgar supplementalcerclagewiringinanglestableplatefixationofdistaltibialspiralfracturesenablesimmediatepostoperativefullweightbearingabiomechanicalanalysis
AT schrodlfalk supplementalcerclagewiringinanglestableplatefixationofdistaltibialspiralfracturesenablesimmediatepostoperativefullweightbearingabiomechanicalanalysis
AT vonrudenchristian supplementalcerclagewiringinanglestableplatefixationofdistaltibialspiralfracturesenablesimmediatepostoperativefullweightbearingabiomechanicalanalysis
AT augatpeter supplementalcerclagewiringinanglestableplatefixationofdistaltibialspiralfracturesenablesimmediatepostoperativefullweightbearingabiomechanicalanalysis