Cargando…

Solid-phase extraction of exosomes from diverse matrices via a polyester capillary-channeled polymer (C-CP) fiber stationary phase in a spin-down tip format

Exosomes, a subset of the extracellular vesicle (EV) group of organelles, hold great potential for biomarker detection, therapeutics, disease diagnosis, and personalized medicine applications. The promise and potential of these applications are hindered by the lack of an efficient means of isolation...

Descripción completa

Detalles Bibliográficos
Autores principales: Jackson, Kaylan K., Powell, Rhonda R., Bruce, Terri F., Marcus, R. Kenneth
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8825614/
https://www.ncbi.nlm.nih.gov/pubmed/32468278
http://dx.doi.org/10.1007/s00216-020-02728-z
_version_ 1784647255434723328
author Jackson, Kaylan K.
Powell, Rhonda R.
Bruce, Terri F.
Marcus, R. Kenneth
author_facet Jackson, Kaylan K.
Powell, Rhonda R.
Bruce, Terri F.
Marcus, R. Kenneth
author_sort Jackson, Kaylan K.
collection PubMed
description Exosomes, a subset of the extracellular vesicle (EV) group of organelles, hold great potential for biomarker detection, therapeutics, disease diagnosis, and personalized medicine applications. The promise and potential of these applications are hindered by the lack of an efficient means of isolation, characterization, and quantitation. Current methods for exosome and EV isolation (including ultracentrifugation, microfiltration, and affinity-based techniques) result in impure recoveries with regard to remnant matrix species (e.g., proteins, genetic material) and are performed on clinically irrelevant time and volume scales. To address these issues, a polyethylene terephthalate (PET) capillary-channeled polymer (C-CP) fiber stationary phase is employed for the solid-phase extraction (SPE) of EVs from various matrices using a micropipette tip-based format. The hydrophobic interaction chromatography (HIC) processing and a spin-down workflow are carried out using a table-top centrifuge. Capture and subsequent elution of intact, biologically active exosomes are verified via electron microscopy and bioassays. The performance of this method was evaluated by capture and elution of exosome standards from buffer solution and three biologically relevant matrices: mock urine, reconstituted non-fat milk, and exosome-depleted fetal bovine serum (FBS). Recoveries were evaluated using UV-Vis absorbance spectrophotometry and ELISA assay. The dynamic binding capacity (50%) for the 1-cm-long (~ 5 μL bed volume) tips was determined using a commercial exosome product, yielding a value of ~ 7 × 10(11) particles. The novel C-CP fiber spin-down tip approach holds promise for the isolation of exosomes and other EVs from various matrices with high throughput, low cost, and high efficiency. [Figure: see text] ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00216-020-02728-z) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-8825614
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-88256142022-02-09 Solid-phase extraction of exosomes from diverse matrices via a polyester capillary-channeled polymer (C-CP) fiber stationary phase in a spin-down tip format Jackson, Kaylan K. Powell, Rhonda R. Bruce, Terri F. Marcus, R. Kenneth Anal Bioanal Chem Research Paper Exosomes, a subset of the extracellular vesicle (EV) group of organelles, hold great potential for biomarker detection, therapeutics, disease diagnosis, and personalized medicine applications. The promise and potential of these applications are hindered by the lack of an efficient means of isolation, characterization, and quantitation. Current methods for exosome and EV isolation (including ultracentrifugation, microfiltration, and affinity-based techniques) result in impure recoveries with regard to remnant matrix species (e.g., proteins, genetic material) and are performed on clinically irrelevant time and volume scales. To address these issues, a polyethylene terephthalate (PET) capillary-channeled polymer (C-CP) fiber stationary phase is employed for the solid-phase extraction (SPE) of EVs from various matrices using a micropipette tip-based format. The hydrophobic interaction chromatography (HIC) processing and a spin-down workflow are carried out using a table-top centrifuge. Capture and subsequent elution of intact, biologically active exosomes are verified via electron microscopy and bioassays. The performance of this method was evaluated by capture and elution of exosome standards from buffer solution and three biologically relevant matrices: mock urine, reconstituted non-fat milk, and exosome-depleted fetal bovine serum (FBS). Recoveries were evaluated using UV-Vis absorbance spectrophotometry and ELISA assay. The dynamic binding capacity (50%) for the 1-cm-long (~ 5 μL bed volume) tips was determined using a commercial exosome product, yielding a value of ~ 7 × 10(11) particles. The novel C-CP fiber spin-down tip approach holds promise for the isolation of exosomes and other EVs from various matrices with high throughput, low cost, and high efficiency. [Figure: see text] ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00216-020-02728-z) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2020-05-28 2020 /pmc/articles/PMC8825614/ /pubmed/32468278 http://dx.doi.org/10.1007/s00216-020-02728-z Text en © Springer-Verlag GmbH Germany, part of Springer Nature 2020 This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.
spellingShingle Research Paper
Jackson, Kaylan K.
Powell, Rhonda R.
Bruce, Terri F.
Marcus, R. Kenneth
Solid-phase extraction of exosomes from diverse matrices via a polyester capillary-channeled polymer (C-CP) fiber stationary phase in a spin-down tip format
title Solid-phase extraction of exosomes from diverse matrices via a polyester capillary-channeled polymer (C-CP) fiber stationary phase in a spin-down tip format
title_full Solid-phase extraction of exosomes from diverse matrices via a polyester capillary-channeled polymer (C-CP) fiber stationary phase in a spin-down tip format
title_fullStr Solid-phase extraction of exosomes from diverse matrices via a polyester capillary-channeled polymer (C-CP) fiber stationary phase in a spin-down tip format
title_full_unstemmed Solid-phase extraction of exosomes from diverse matrices via a polyester capillary-channeled polymer (C-CP) fiber stationary phase in a spin-down tip format
title_short Solid-phase extraction of exosomes from diverse matrices via a polyester capillary-channeled polymer (C-CP) fiber stationary phase in a spin-down tip format
title_sort solid-phase extraction of exosomes from diverse matrices via a polyester capillary-channeled polymer (c-cp) fiber stationary phase in a spin-down tip format
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8825614/
https://www.ncbi.nlm.nih.gov/pubmed/32468278
http://dx.doi.org/10.1007/s00216-020-02728-z
work_keys_str_mv AT jacksonkaylank solidphaseextractionofexosomesfromdiversematricesviaapolyestercapillarychanneledpolymerccpfiberstationaryphaseinaspindowntipformat
AT powellrhondar solidphaseextractionofexosomesfromdiversematricesviaapolyestercapillarychanneledpolymerccpfiberstationaryphaseinaspindowntipformat
AT bruceterrif solidphaseextractionofexosomesfromdiversematricesviaapolyestercapillarychanneledpolymerccpfiberstationaryphaseinaspindowntipformat
AT marcusrkenneth solidphaseextractionofexosomesfromdiversematricesviaapolyestercapillarychanneledpolymerccpfiberstationaryphaseinaspindowntipformat