Cargando…
86057 High Screening Efficacy Using Wearable Seismocardiography to Identify Aortic Valve Disease Patients, Potential to Tailor MRI Exams to Patient Needs
ABSTRACT IMPACT: A single seismocardiography (SCG) parameter has been shown to accurately classify aortic valve disease (AVD) status in healthy controls and AVD patients. This could support development of SCG as a quick, inexpensive screening tool to better tailor MRI examination to patients’ needs....
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cambridge University Press
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8827962/ http://dx.doi.org/10.1017/cts.2021.640 |
_version_ | 1784647757007421440 |
---|---|
author | Johnson, Ethan M.I. Barker, Alex J. Markl, Michael |
author_facet | Johnson, Ethan M.I. Barker, Alex J. Markl, Michael |
author_sort | Johnson, Ethan M.I. |
collection | PubMed |
description | ABSTRACT IMPACT: A single seismocardiography (SCG) parameter has been shown to accurately classify aortic valve disease (AVD) status in healthy controls and AVD patients. This could support development of SCG as a quick, inexpensive screening tool to better tailor MRI examination to patients’ needs. OBJECTIVES/GOALS: MRI is used commonly for monitoring of aortic valve disease (AVD), but it has high costs. We hypothesize that energy in seismocardiograms (SCG)’‘ signals from chest surface vibrations’‘ is different between healthy controls and AVD patients, and we evaluate potential efficacy of using SCG to recommend MRI only for patients with flow abnormalities. METHODS/STUDY POPULATION: With IRB approval, 45 healthy control subjects (47 ±18years, 18 female) and 9 patients (63 ±16years, 2 female) with aortic valve disease history and known flow abnormalities were recruited. SCG signals were acquired supine, immediately prior to MRI of thoracic aortic blood flow at 1.5T with a time-resolved phase contrast (4D Flow) sequence. The SCG was processed to calculate late-systole high-frequency (120-240Hz) RMS energy. MR velocity images were analyzed to measure peak velocity and trace pathlines of flow. Screening efficacy of the SCG energy metric was assessed, with hypothesis testing for differences in energy level distributions between controls and patients, and receiver-operator characteristic (ROC) analysis was used to calculate rates of correct/incorrect classification of disease. RESULTS/ANTICIPATED RESULTS: Healthy subjects had coherent flow pathlines through the aortic arch and mid-ascending aorta peak velocities of 106 ±21cm/s (cohort mean ±standard deviation). All valve disease subjects had flow abnormalities, such as jetting flow near the valve or swirling through the arch, as visualized by pathlines. Patients’ peak mid-ascending aorta velocities were 167 ±69cm/s. The SCG energy for healthy controls was significantly different than that of valve patients (-5.6 ±0.3dBmm/s/s vs. -4.0 ±1.2dBmm/s/s respectively; p<0.001). Thresholding SCG energy to distinguish patients from controls correctly classifies subjects with a high true-positive rate and low false-positive rate. The ROC for this classification has area-under-curve 0.956. DISCUSSION/SIGNIFICANCE OF FINDINGS: A high potential screening efficacy was observed using a single, linear SCG metric to identify AVD patients with flow abnormalities. If used to complement MRI surveillance protocols for AVD, this method has potential to serve as a quick, inexpensive tool for better tailoring MRI exams to patient needs. |
format | Online Article Text |
id | pubmed-8827962 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Cambridge University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-88279622022-02-28 86057 High Screening Efficacy Using Wearable Seismocardiography to Identify Aortic Valve Disease Patients, Potential to Tailor MRI Exams to Patient Needs Johnson, Ethan M.I. Barker, Alex J. Markl, Michael J Clin Transl Sci Mechanistic Basic to Clinical ABSTRACT IMPACT: A single seismocardiography (SCG) parameter has been shown to accurately classify aortic valve disease (AVD) status in healthy controls and AVD patients. This could support development of SCG as a quick, inexpensive screening tool to better tailor MRI examination to patients’ needs. OBJECTIVES/GOALS: MRI is used commonly for monitoring of aortic valve disease (AVD), but it has high costs. We hypothesize that energy in seismocardiograms (SCG)’‘ signals from chest surface vibrations’‘ is different between healthy controls and AVD patients, and we evaluate potential efficacy of using SCG to recommend MRI only for patients with flow abnormalities. METHODS/STUDY POPULATION: With IRB approval, 45 healthy control subjects (47 ±18years, 18 female) and 9 patients (63 ±16years, 2 female) with aortic valve disease history and known flow abnormalities were recruited. SCG signals were acquired supine, immediately prior to MRI of thoracic aortic blood flow at 1.5T with a time-resolved phase contrast (4D Flow) sequence. The SCG was processed to calculate late-systole high-frequency (120-240Hz) RMS energy. MR velocity images were analyzed to measure peak velocity and trace pathlines of flow. Screening efficacy of the SCG energy metric was assessed, with hypothesis testing for differences in energy level distributions between controls and patients, and receiver-operator characteristic (ROC) analysis was used to calculate rates of correct/incorrect classification of disease. RESULTS/ANTICIPATED RESULTS: Healthy subjects had coherent flow pathlines through the aortic arch and mid-ascending aorta peak velocities of 106 ±21cm/s (cohort mean ±standard deviation). All valve disease subjects had flow abnormalities, such as jetting flow near the valve or swirling through the arch, as visualized by pathlines. Patients’ peak mid-ascending aorta velocities were 167 ±69cm/s. The SCG energy for healthy controls was significantly different than that of valve patients (-5.6 ±0.3dBmm/s/s vs. -4.0 ±1.2dBmm/s/s respectively; p<0.001). Thresholding SCG energy to distinguish patients from controls correctly classifies subjects with a high true-positive rate and low false-positive rate. The ROC for this classification has area-under-curve 0.956. DISCUSSION/SIGNIFICANCE OF FINDINGS: A high potential screening efficacy was observed using a single, linear SCG metric to identify AVD patients with flow abnormalities. If used to complement MRI surveillance protocols for AVD, this method has potential to serve as a quick, inexpensive tool for better tailoring MRI exams to patient needs. Cambridge University Press 2021-03-31 /pmc/articles/PMC8827962/ http://dx.doi.org/10.1017/cts.2021.640 Text en © The Association for Clinical and Translational Science 2021 https://creativecommons.org/licenses/by/4.0/This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Mechanistic Basic to Clinical Johnson, Ethan M.I. Barker, Alex J. Markl, Michael 86057 High Screening Efficacy Using Wearable Seismocardiography to Identify Aortic Valve Disease Patients, Potential to Tailor MRI Exams to Patient Needs |
title | 86057 High Screening Efficacy Using Wearable Seismocardiography to Identify Aortic Valve Disease Patients, Potential to Tailor MRI Exams to Patient Needs |
title_full | 86057 High Screening Efficacy Using Wearable Seismocardiography to Identify Aortic Valve Disease Patients, Potential to Tailor MRI Exams to Patient Needs |
title_fullStr | 86057 High Screening Efficacy Using Wearable Seismocardiography to Identify Aortic Valve Disease Patients, Potential to Tailor MRI Exams to Patient Needs |
title_full_unstemmed | 86057 High Screening Efficacy Using Wearable Seismocardiography to Identify Aortic Valve Disease Patients, Potential to Tailor MRI Exams to Patient Needs |
title_short | 86057 High Screening Efficacy Using Wearable Seismocardiography to Identify Aortic Valve Disease Patients, Potential to Tailor MRI Exams to Patient Needs |
title_sort | 86057 high screening efficacy using wearable seismocardiography to identify aortic valve disease patients, potential to tailor mri exams to patient needs |
topic | Mechanistic Basic to Clinical |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8827962/ http://dx.doi.org/10.1017/cts.2021.640 |
work_keys_str_mv | AT johnsonethanmi 86057highscreeningefficacyusingwearableseismocardiographytoidentifyaorticvalvediseasepatientspotentialtotailormriexamstopatientneeds AT barkeralexj 86057highscreeningefficacyusingwearableseismocardiographytoidentifyaorticvalvediseasepatientspotentialtotailormriexamstopatientneeds AT marklmichael 86057highscreeningefficacyusingwearableseismocardiographytoidentifyaorticvalvediseasepatientspotentialtotailormriexamstopatientneeds |