Cargando…
44190 Comparing the Accuracy of Different Tools in Identifying Glaucoma Medication Non-adherence
ABSTRACT IMPACT: Medication non-adherence is a widespread problem in glaucoma care, and this abstract shows that a free and easy to implement tool can be used to accurately screen and identify patients who are not adherent to their glaucoma medication. OBJECTIVES/GOALS: To compare the accuracy of ph...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cambridge University Press
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8827975/ http://dx.doi.org/10.1017/cts.2021.725 |
Sumario: | ABSTRACT IMPACT: Medication non-adherence is a widespread problem in glaucoma care, and this abstract shows that a free and easy to implement tool can be used to accurately screen and identify patients who are not adherent to their glaucoma medication. OBJECTIVES/GOALS: To compare the accuracy of pharmacy refill data and five measures of self-reported adherence in identifying patients with poor electronically monitored glaucoma medication adherence. METHODS/STUDY POPULATION: Glaucoma patients (age ≥40, poor self-reported adherence, and ≥1 medication) recruited at the University of Michigan completed five surveys of adherence and 3-months of electronically monitored medication adherence; pharmacy refill data were obtained. Electronically monitored adherence was summarized monthly as percent of doses taken on time. Median monthly adherence ≤80% was considered non-adherent. Pharmacy refill data were reported as the proportion of days covered. The accuracy of the measures in predicting ≤80% adherence was assessed with receiver operating characteristic curves such as estimation of area under the curve (AUC), sensitivity, specificity, and accuracy. RESULTS/ANTICIPATED RESULTS: 95 patients completed electronic monitoring with a median monthly adherence of 74% (±21%); 53 patients (56%) were non-adherent. Pharmacy refill adherence was not significantly correlated with electronically monitored medication adherence (r=0.12, p=0.2). A single-item adherence question (‘Over the past month, what percentage of your drops do you think you took correctly?’) had the largest correlation with electronically monitored adherence (r=0.47, p<0.0001), the largest AUC for predicting non-adherence (AUC= 0.76, [95% Confidence Interval = 0.66, 0.87]), best accuracy (71%, [61, 82]), and good sensitivity (84%, [73, 96]). DISCUSSION/SIGNIFICANCE OF FINDINGS: A free, single-item screening question ('Over the past month, what percentage of your drops do you think you took correctly?') offers an easy-to-implement tool for identifying glaucoma patients with poor medication adherence in clinical practice. |
---|