Cargando…
Efficacy of 6‐mm diameter fully covered self‐expandable metallic stents in preoperative biliary drainage for pancreatic ductal adenocarcinoma
OBJECTIVES: Plastic stents (PS) used for preoperative biliary drainage (PBD) of pancreatic ductal adenocarcinomas (PDAC) tend to be associated with a high incidence of recurrent biliary obstruction (RBO). Although 10‐mm diameter fully covered self‐expanding metallic stents (FCSEMS) have come into us...
Autores principales: | , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8828181/ https://www.ncbi.nlm.nih.gov/pubmed/35310700 http://dx.doi.org/10.1002/deo2.55 |
_version_ | 1784647790344798208 |
---|---|
author | Kataoka, Fumiya Inoue, Dai Watanabe, Masato Fukuda, Keita Nobusawa, Tsubasa Umemura, Kayo Miura, Natsuki Yokota, Takuya Yoshioka, Astushi Shimoji, Kohei Nakazono, Ayano Horike, Hideyuki Ogura, Yuki Hayashi, Tatsuya Morita, Yasuhiro Namiki, Shin |
author_facet | Kataoka, Fumiya Inoue, Dai Watanabe, Masato Fukuda, Keita Nobusawa, Tsubasa Umemura, Kayo Miura, Natsuki Yokota, Takuya Yoshioka, Astushi Shimoji, Kohei Nakazono, Ayano Horike, Hideyuki Ogura, Yuki Hayashi, Tatsuya Morita, Yasuhiro Namiki, Shin |
author_sort | Kataoka, Fumiya |
collection | PubMed |
description | OBJECTIVES: Plastic stents (PS) used for preoperative biliary drainage (PBD) of pancreatic ductal adenocarcinomas (PDAC) tend to be associated with a high incidence of recurrent biliary obstruction (RBO). Although 10‐mm diameter fully covered self‐expanding metallic stents (FCSEMS) have come into use, vigilance is still required to prevent complications, such as cholecystitis and surgical site infection. The present study examined the efficacy and safety of the 6‐mm diameter FCSEMS for PBD. METHODS: The present retrospective study compared the incidence of complications associated with the use of 6‐mm FCSEMS and PS. The inclusion criteria were a diagnosis of PDAC and preoperative endoscopic biliary tract drainage performed at our institution between April 2012 and June 2019. RESULTS: Of the 51 patients enrolled, 25 and 26 patients received a PS and a 6‐mm FCSEMS, respectively. The RBO incidence was significantly lower in the 6‐mm FCSEMS group (7.7%) than in the PS group (40.0%) (p = 0.009), and time to RBO was significantly longer in the 6‐mm FCSEMS group (HR = 6.008, p = 0.021). The patency rate at three months after stent placement was significantly higher in the latter group (83.5% vs. 45.3%, p = 0.009, Log‐rank test). The groups did not differ significantly in terms of complications associated with PBD, such as cholecystitis and surgical site infection. CONCLUSION: The present findings suggested that the 6‐mm FCSEMS may be an effective drainage device for use in PBD in PDAC treatment. |
format | Online Article Text |
id | pubmed-8828181 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-88281812022-03-17 Efficacy of 6‐mm diameter fully covered self‐expandable metallic stents in preoperative biliary drainage for pancreatic ductal adenocarcinoma Kataoka, Fumiya Inoue, Dai Watanabe, Masato Fukuda, Keita Nobusawa, Tsubasa Umemura, Kayo Miura, Natsuki Yokota, Takuya Yoshioka, Astushi Shimoji, Kohei Nakazono, Ayano Horike, Hideyuki Ogura, Yuki Hayashi, Tatsuya Morita, Yasuhiro Namiki, Shin DEN Open Original Articles OBJECTIVES: Plastic stents (PS) used for preoperative biliary drainage (PBD) of pancreatic ductal adenocarcinomas (PDAC) tend to be associated with a high incidence of recurrent biliary obstruction (RBO). Although 10‐mm diameter fully covered self‐expanding metallic stents (FCSEMS) have come into use, vigilance is still required to prevent complications, such as cholecystitis and surgical site infection. The present study examined the efficacy and safety of the 6‐mm diameter FCSEMS for PBD. METHODS: The present retrospective study compared the incidence of complications associated with the use of 6‐mm FCSEMS and PS. The inclusion criteria were a diagnosis of PDAC and preoperative endoscopic biliary tract drainage performed at our institution between April 2012 and June 2019. RESULTS: Of the 51 patients enrolled, 25 and 26 patients received a PS and a 6‐mm FCSEMS, respectively. The RBO incidence was significantly lower in the 6‐mm FCSEMS group (7.7%) than in the PS group (40.0%) (p = 0.009), and time to RBO was significantly longer in the 6‐mm FCSEMS group (HR = 6.008, p = 0.021). The patency rate at three months after stent placement was significantly higher in the latter group (83.5% vs. 45.3%, p = 0.009, Log‐rank test). The groups did not differ significantly in terms of complications associated with PBD, such as cholecystitis and surgical site infection. CONCLUSION: The present findings suggested that the 6‐mm FCSEMS may be an effective drainage device for use in PBD in PDAC treatment. John Wiley and Sons Inc. 2021-09-08 /pmc/articles/PMC8828181/ /pubmed/35310700 http://dx.doi.org/10.1002/deo2.55 Text en © 2021 The Authors. DEN Open published by John Wiley & Sons Australia, Ltd on behalf of Japan Gastroenterological Endoscopy Society https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Articles Kataoka, Fumiya Inoue, Dai Watanabe, Masato Fukuda, Keita Nobusawa, Tsubasa Umemura, Kayo Miura, Natsuki Yokota, Takuya Yoshioka, Astushi Shimoji, Kohei Nakazono, Ayano Horike, Hideyuki Ogura, Yuki Hayashi, Tatsuya Morita, Yasuhiro Namiki, Shin Efficacy of 6‐mm diameter fully covered self‐expandable metallic stents in preoperative biliary drainage for pancreatic ductal adenocarcinoma |
title | Efficacy of 6‐mm diameter fully covered self‐expandable metallic stents in preoperative biliary drainage for pancreatic ductal adenocarcinoma |
title_full | Efficacy of 6‐mm diameter fully covered self‐expandable metallic stents in preoperative biliary drainage for pancreatic ductal adenocarcinoma |
title_fullStr | Efficacy of 6‐mm diameter fully covered self‐expandable metallic stents in preoperative biliary drainage for pancreatic ductal adenocarcinoma |
title_full_unstemmed | Efficacy of 6‐mm diameter fully covered self‐expandable metallic stents in preoperative biliary drainage for pancreatic ductal adenocarcinoma |
title_short | Efficacy of 6‐mm diameter fully covered self‐expandable metallic stents in preoperative biliary drainage for pancreatic ductal adenocarcinoma |
title_sort | efficacy of 6‐mm diameter fully covered self‐expandable metallic stents in preoperative biliary drainage for pancreatic ductal adenocarcinoma |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8828181/ https://www.ncbi.nlm.nih.gov/pubmed/35310700 http://dx.doi.org/10.1002/deo2.55 |
work_keys_str_mv | AT kataokafumiya efficacyof6mmdiameterfullycoveredselfexpandablemetallicstentsinpreoperativebiliarydrainageforpancreaticductaladenocarcinoma AT inouedai efficacyof6mmdiameterfullycoveredselfexpandablemetallicstentsinpreoperativebiliarydrainageforpancreaticductaladenocarcinoma AT watanabemasato efficacyof6mmdiameterfullycoveredselfexpandablemetallicstentsinpreoperativebiliarydrainageforpancreaticductaladenocarcinoma AT fukudakeita efficacyof6mmdiameterfullycoveredselfexpandablemetallicstentsinpreoperativebiliarydrainageforpancreaticductaladenocarcinoma AT nobusawatsubasa efficacyof6mmdiameterfullycoveredselfexpandablemetallicstentsinpreoperativebiliarydrainageforpancreaticductaladenocarcinoma AT umemurakayo efficacyof6mmdiameterfullycoveredselfexpandablemetallicstentsinpreoperativebiliarydrainageforpancreaticductaladenocarcinoma AT miuranatsuki efficacyof6mmdiameterfullycoveredselfexpandablemetallicstentsinpreoperativebiliarydrainageforpancreaticductaladenocarcinoma AT yokotatakuya efficacyof6mmdiameterfullycoveredselfexpandablemetallicstentsinpreoperativebiliarydrainageforpancreaticductaladenocarcinoma AT yoshiokaastushi efficacyof6mmdiameterfullycoveredselfexpandablemetallicstentsinpreoperativebiliarydrainageforpancreaticductaladenocarcinoma AT shimojikohei efficacyof6mmdiameterfullycoveredselfexpandablemetallicstentsinpreoperativebiliarydrainageforpancreaticductaladenocarcinoma AT nakazonoayano efficacyof6mmdiameterfullycoveredselfexpandablemetallicstentsinpreoperativebiliarydrainageforpancreaticductaladenocarcinoma AT horikehideyuki efficacyof6mmdiameterfullycoveredselfexpandablemetallicstentsinpreoperativebiliarydrainageforpancreaticductaladenocarcinoma AT ogurayuki efficacyof6mmdiameterfullycoveredselfexpandablemetallicstentsinpreoperativebiliarydrainageforpancreaticductaladenocarcinoma AT hayashitatsuya efficacyof6mmdiameterfullycoveredselfexpandablemetallicstentsinpreoperativebiliarydrainageforpancreaticductaladenocarcinoma AT moritayasuhiro efficacyof6mmdiameterfullycoveredselfexpandablemetallicstentsinpreoperativebiliarydrainageforpancreaticductaladenocarcinoma AT namikishin efficacyof6mmdiameterfullycoveredselfexpandablemetallicstentsinpreoperativebiliarydrainageforpancreaticductaladenocarcinoma |