Cargando…

Comparisons of outcomes between ProKnife injection endoscopic submucosal dissection and conventional endoscopic submucosal dissection for large gastric lesions in ex vivo porcine model study: A randomized controlled trial

OBJECTIVE: To compare treatment outcomes between injection endoscopic submucosal dissection using ProKnife (P‐ESD) and conventional ESD (C‐ESD) for gastric lesions. METHODS: In this randomized controlled trial, we compared treatment outcomes of P‐ESD and C‐ESD for simulated gastric lesions ≥3 cm in...

Descripción completa

Detalles Bibliográficos
Autores principales: Esaki, Mitsuru, Ihara, Eikichi, Esaki, Misato, Nishioka, Kei, Kimura, Yusuke, Hata, Yoshitaka, Tsuru, Hirotaka, Wada, Masafumi, Minoda, Yosuke, Bai, Xiaopeng, Shoguchi, Yoshihisa, Nasu, Takayuki, Nagatomo, Shuzaburo, Muta, Kazumasa, Ogino, Haruei, Ogawa, Yoshihiro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8828196/
https://www.ncbi.nlm.nih.gov/pubmed/35310697
http://dx.doi.org/10.1002/deo2.91
Descripción
Sumario:OBJECTIVE: To compare treatment outcomes between injection endoscopic submucosal dissection using ProKnife (P‐ESD) and conventional ESD (C‐ESD) for gastric lesions. METHODS: In this randomized controlled trial, we compared treatment outcomes of P‐ESD and C‐ESD for simulated gastric lesions ≥3 cm in resected porcine stomachs. Predictive factors associated with ESD difficulties were investigated using logistic regression analysis. RESULTS: Seventy lesions were screened; however, two lesions were excluded. A total of 12 endoscopists performed 68 ESDs: 34 P‐ESDs and 34 C‐ESDs. The ESD procedure time of P‐ESD (36.3 [28.4–46.8] min) was significantly shorter than that of C‐ESD (46 [36.4–64.6] min; p = 0.0014). The technical success rates did not differ between the P‐ESD and C‐ESD groups (en bloc resection rate, 100% in both groups; complete resection rate, 94.1% and 85.3%, respectively; p = 0.23). The number of injections during P‐ESD (7.5 [6–10] times) was significantly higher than during C‐ESD (4 [3–5] times; p < 0.001), but the total volume of injected solution during P‐ESD (20 [16–26.3] ml) was significantly smaller than during C‐ESD (27.5 [20–31.5] ml; p = 0.0019). In multivariate analysis, less ESD experience (odds ratio [OR], 3.9) and selection of C‐ESD as the ESD method (OR, 3.8) were independent predictive factors associated with ESD difficulties. CONCLUSIONS: Compared with C‐ESD, P‐ESD had a shorter procedure time but also allowed for notable technical success and safety.