Cargando…

Comparison of landmark and real-time ultrasound-guided epidural catheter placement in the pediatric population: a prospective randomized comparative trial

BACKGROUND: Epidural block placement in pediatric patients is technically challenging for anesthesiologists. The use of ultrasound (US) for the placement of an epidural catheter has shown promise. We compared landmark-guided and US-guided lumbar or lower thoracic epidural needle placement in pediatr...

Descripción completa

Detalles Bibliográficos
Autores principales: Mital, Tanya, Kamal, Manoj, Kumar, Mritunjay, Kumar, Rakesh, Bhatia, Pradeep, Singariya, Geeta
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Anesthesiologists 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8828618/
https://www.ncbi.nlm.nih.gov/pubmed/35139618
http://dx.doi.org/10.17085/apm.21035
_version_ 1784647888759947264
author Mital, Tanya
Kamal, Manoj
Kumar, Mritunjay
Kumar, Rakesh
Bhatia, Pradeep
Singariya, Geeta
author_facet Mital, Tanya
Kamal, Manoj
Kumar, Mritunjay
Kumar, Rakesh
Bhatia, Pradeep
Singariya, Geeta
author_sort Mital, Tanya
collection PubMed
description BACKGROUND: Epidural block placement in pediatric patients is technically challenging for anesthesiologists. The use of ultrasound (US) for the placement of an epidural catheter has shown promise. We compared landmark-guided and US-guided lumbar or lower thoracic epidural needle placement in pediatric patients. METHODS: This prospective, randomized, comparative trial involved children aged 1–6 years who underwent abdominal and thoracic surgeries. Forty-five children were randomly divided into two groups using a computer-generated random number table, and group allocation was performed by the sealed opaque method into either landmark-guided (group LT) or real-time ultrasound-guided (group UT) epidural placement. The primary outcome was a comparison of the procedure time (excluding US probe preparation). Secondary outcomes were the number of attempts (re-insertion of the needle), bone contacts, needle redirection, skin-to-epidural distance using the US in both groups, success rate, and complications. RESULTS: The median (interquartile range) time to reach epidural space was 105.5 (297.0) seconds in group LT and 143.0 (150) seconds in group UT (P = 0.407). While the first attempt success rate was higher in the UT group (87.0% in UT vs. 40.9% in LT; P = 0.004), the number of bone contacts, needle redirections, and procedure-related complications were significantly lower. CONCLUSIONS: The use of US significantly reduced needle redirection, number of attempts, bone contact, and complications. There was no statistically significant difference in the time to access the epidural space between the US and landmark technique groups.
format Online
Article
Text
id pubmed-8828618
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Korean Society of Anesthesiologists
record_format MEDLINE/PubMed
spelling pubmed-88286182022-02-18 Comparison of landmark and real-time ultrasound-guided epidural catheter placement in the pediatric population: a prospective randomized comparative trial Mital, Tanya Kamal, Manoj Kumar, Mritunjay Kumar, Rakesh Bhatia, Pradeep Singariya, Geeta Anesth Pain Med (Seoul) Regional Anesthesia BACKGROUND: Epidural block placement in pediatric patients is technically challenging for anesthesiologists. The use of ultrasound (US) for the placement of an epidural catheter has shown promise. We compared landmark-guided and US-guided lumbar or lower thoracic epidural needle placement in pediatric patients. METHODS: This prospective, randomized, comparative trial involved children aged 1–6 years who underwent abdominal and thoracic surgeries. Forty-five children were randomly divided into two groups using a computer-generated random number table, and group allocation was performed by the sealed opaque method into either landmark-guided (group LT) or real-time ultrasound-guided (group UT) epidural placement. The primary outcome was a comparison of the procedure time (excluding US probe preparation). Secondary outcomes were the number of attempts (re-insertion of the needle), bone contacts, needle redirection, skin-to-epidural distance using the US in both groups, success rate, and complications. RESULTS: The median (interquartile range) time to reach epidural space was 105.5 (297.0) seconds in group LT and 143.0 (150) seconds in group UT (P = 0.407). While the first attempt success rate was higher in the UT group (87.0% in UT vs. 40.9% in LT; P = 0.004), the number of bone contacts, needle redirections, and procedure-related complications were significantly lower. CONCLUSIONS: The use of US significantly reduced needle redirection, number of attempts, bone contact, and complications. There was no statistically significant difference in the time to access the epidural space between the US and landmark technique groups. Korean Society of Anesthesiologists 2021-10-30 2021-10-14 /pmc/articles/PMC8828618/ /pubmed/35139618 http://dx.doi.org/10.17085/apm.21035 Text en Copyright © the Korean Society of Anesthesiologists, 2021 https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Regional Anesthesia
Mital, Tanya
Kamal, Manoj
Kumar, Mritunjay
Kumar, Rakesh
Bhatia, Pradeep
Singariya, Geeta
Comparison of landmark and real-time ultrasound-guided epidural catheter placement in the pediatric population: a prospective randomized comparative trial
title Comparison of landmark and real-time ultrasound-guided epidural catheter placement in the pediatric population: a prospective randomized comparative trial
title_full Comparison of landmark and real-time ultrasound-guided epidural catheter placement in the pediatric population: a prospective randomized comparative trial
title_fullStr Comparison of landmark and real-time ultrasound-guided epidural catheter placement in the pediatric population: a prospective randomized comparative trial
title_full_unstemmed Comparison of landmark and real-time ultrasound-guided epidural catheter placement in the pediatric population: a prospective randomized comparative trial
title_short Comparison of landmark and real-time ultrasound-guided epidural catheter placement in the pediatric population: a prospective randomized comparative trial
title_sort comparison of landmark and real-time ultrasound-guided epidural catheter placement in the pediatric population: a prospective randomized comparative trial
topic Regional Anesthesia
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8828618/
https://www.ncbi.nlm.nih.gov/pubmed/35139618
http://dx.doi.org/10.17085/apm.21035
work_keys_str_mv AT mitaltanya comparisonoflandmarkandrealtimeultrasoundguidedepiduralcatheterplacementinthepediatricpopulationaprospectiverandomizedcomparativetrial
AT kamalmanoj comparisonoflandmarkandrealtimeultrasoundguidedepiduralcatheterplacementinthepediatricpopulationaprospectiverandomizedcomparativetrial
AT kumarmritunjay comparisonoflandmarkandrealtimeultrasoundguidedepiduralcatheterplacementinthepediatricpopulationaprospectiverandomizedcomparativetrial
AT kumarrakesh comparisonoflandmarkandrealtimeultrasoundguidedepiduralcatheterplacementinthepediatricpopulationaprospectiverandomizedcomparativetrial
AT bhatiapradeep comparisonoflandmarkandrealtimeultrasoundguidedepiduralcatheterplacementinthepediatricpopulationaprospectiverandomizedcomparativetrial
AT singariyageeta comparisonoflandmarkandrealtimeultrasoundguidedepiduralcatheterplacementinthepediatricpopulationaprospectiverandomizedcomparativetrial