Cargando…
Image quality and diagnostic accuracy of reduced-dose computed tomography enterography with model-based iterative reconstruction in pediatric Crohn’s disease patients
This study assessed the image quality and diagnostic accuracy in determining disease activity of the terminal ileum of the reduced-dose computed tomography enterography using model-based iterative reconstruction in pediatric patients with Crohn’s disease (CD). Eighteen patients were prospectively en...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8828853/ https://www.ncbi.nlm.nih.gov/pubmed/35140296 http://dx.doi.org/10.1038/s41598-022-06246-z |
_version_ | 1784647932186722304 |
---|---|
author | Lee, Yeoun Joo Hwang, Jae-Yeon Ryu, Hwaseong Kim, Tae Un Kim, Yong-Woo Park, Jae Hong Choo, Ki Seok Nam, Kyung Jin Roh, Jieun |
author_facet | Lee, Yeoun Joo Hwang, Jae-Yeon Ryu, Hwaseong Kim, Tae Un Kim, Yong-Woo Park, Jae Hong Choo, Ki Seok Nam, Kyung Jin Roh, Jieun |
author_sort | Lee, Yeoun Joo |
collection | PubMed |
description | This study assessed the image quality and diagnostic accuracy in determining disease activity of the terminal ileum of the reduced-dose computed tomography enterography using model-based iterative reconstruction in pediatric patients with Crohn’s disease (CD). Eighteen patients were prospectively enrolled and allocated to the standard-dose (SD) and reduced-dose (RD) computed tomography enterography (CTE) groups (n = 9 per group). Image quality, reader confidence in interpreting bowel findings, accuracy in determining active CD in the terminal ileum, and radiation dose were evaluated. Objective image quality did not show intergroup differences, except for image sharpness. Although reader confidence in detecting mural stratification, ulcer, and perienteric fat stranding of the RD-CTE were inferior to SD-CTE, RD-CTE correctly diagnosed active disease in all patients. The mean values of radiation dose metrics (SD-CTE vs. RD-CTE) were 4.3 versus 0.74 mGy, 6.1 versus 1.1 mGy, 211.9 versus 34.5 mGy∙cm, and 4.4 versus 0.7 mSv mGy∙cm for CTDI(vol), size-specific dose estimation, dose-length product, and effective dose, respectively. RD-CTE showed comparable diagnostic accuracy to SD-CTE in determining active disease of the terminal ileum in pediatric CD patients. However, image quality and reader confidence in detecting ulcer and perienteric fat stranding was compromised. |
format | Online Article Text |
id | pubmed-8828853 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-88288532022-02-10 Image quality and diagnostic accuracy of reduced-dose computed tomography enterography with model-based iterative reconstruction in pediatric Crohn’s disease patients Lee, Yeoun Joo Hwang, Jae-Yeon Ryu, Hwaseong Kim, Tae Un Kim, Yong-Woo Park, Jae Hong Choo, Ki Seok Nam, Kyung Jin Roh, Jieun Sci Rep Article This study assessed the image quality and diagnostic accuracy in determining disease activity of the terminal ileum of the reduced-dose computed tomography enterography using model-based iterative reconstruction in pediatric patients with Crohn’s disease (CD). Eighteen patients were prospectively enrolled and allocated to the standard-dose (SD) and reduced-dose (RD) computed tomography enterography (CTE) groups (n = 9 per group). Image quality, reader confidence in interpreting bowel findings, accuracy in determining active CD in the terminal ileum, and radiation dose were evaluated. Objective image quality did not show intergroup differences, except for image sharpness. Although reader confidence in detecting mural stratification, ulcer, and perienteric fat stranding of the RD-CTE were inferior to SD-CTE, RD-CTE correctly diagnosed active disease in all patients. The mean values of radiation dose metrics (SD-CTE vs. RD-CTE) were 4.3 versus 0.74 mGy, 6.1 versus 1.1 mGy, 211.9 versus 34.5 mGy∙cm, and 4.4 versus 0.7 mSv mGy∙cm for CTDI(vol), size-specific dose estimation, dose-length product, and effective dose, respectively. RD-CTE showed comparable diagnostic accuracy to SD-CTE in determining active disease of the terminal ileum in pediatric CD patients. However, image quality and reader confidence in detecting ulcer and perienteric fat stranding was compromised. Nature Publishing Group UK 2022-02-09 /pmc/articles/PMC8828853/ /pubmed/35140296 http://dx.doi.org/10.1038/s41598-022-06246-z Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Lee, Yeoun Joo Hwang, Jae-Yeon Ryu, Hwaseong Kim, Tae Un Kim, Yong-Woo Park, Jae Hong Choo, Ki Seok Nam, Kyung Jin Roh, Jieun Image quality and diagnostic accuracy of reduced-dose computed tomography enterography with model-based iterative reconstruction in pediatric Crohn’s disease patients |
title | Image quality and diagnostic accuracy of reduced-dose computed tomography enterography with model-based iterative reconstruction in pediatric Crohn’s disease patients |
title_full | Image quality and diagnostic accuracy of reduced-dose computed tomography enterography with model-based iterative reconstruction in pediatric Crohn’s disease patients |
title_fullStr | Image quality and diagnostic accuracy of reduced-dose computed tomography enterography with model-based iterative reconstruction in pediatric Crohn’s disease patients |
title_full_unstemmed | Image quality and diagnostic accuracy of reduced-dose computed tomography enterography with model-based iterative reconstruction in pediatric Crohn’s disease patients |
title_short | Image quality and diagnostic accuracy of reduced-dose computed tomography enterography with model-based iterative reconstruction in pediatric Crohn’s disease patients |
title_sort | image quality and diagnostic accuracy of reduced-dose computed tomography enterography with model-based iterative reconstruction in pediatric crohn’s disease patients |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8828853/ https://www.ncbi.nlm.nih.gov/pubmed/35140296 http://dx.doi.org/10.1038/s41598-022-06246-z |
work_keys_str_mv | AT leeyeounjoo imagequalityanddiagnosticaccuracyofreduceddosecomputedtomographyenterographywithmodelbasediterativereconstructioninpediatriccrohnsdiseasepatients AT hwangjaeyeon imagequalityanddiagnosticaccuracyofreduceddosecomputedtomographyenterographywithmodelbasediterativereconstructioninpediatriccrohnsdiseasepatients AT ryuhwaseong imagequalityanddiagnosticaccuracyofreduceddosecomputedtomographyenterographywithmodelbasediterativereconstructioninpediatriccrohnsdiseasepatients AT kimtaeun imagequalityanddiagnosticaccuracyofreduceddosecomputedtomographyenterographywithmodelbasediterativereconstructioninpediatriccrohnsdiseasepatients AT kimyongwoo imagequalityanddiagnosticaccuracyofreduceddosecomputedtomographyenterographywithmodelbasediterativereconstructioninpediatriccrohnsdiseasepatients AT parkjaehong imagequalityanddiagnosticaccuracyofreduceddosecomputedtomographyenterographywithmodelbasediterativereconstructioninpediatriccrohnsdiseasepatients AT chookiseok imagequalityanddiagnosticaccuracyofreduceddosecomputedtomographyenterographywithmodelbasediterativereconstructioninpediatriccrohnsdiseasepatients AT namkyungjin imagequalityanddiagnosticaccuracyofreduceddosecomputedtomographyenterographywithmodelbasediterativereconstructioninpediatriccrohnsdiseasepatients AT rohjieun imagequalityanddiagnosticaccuracyofreduceddosecomputedtomographyenterographywithmodelbasediterativereconstructioninpediatriccrohnsdiseasepatients |